Cargando…
High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression
BACKGROUND: Fat suppression is an important technique in magnetic resonance imaging (MRI). Comprehensive and quantitative assessment of the influence of fat suppression (FS) on T1-weighted imaging of intracranial vessel wall imaging is needed. In this study, we compared the three-dimensional (3D) va...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7657061/ https://www.ncbi.nlm.nih.gov/pubmed/33159730 http://dx.doi.org/10.12659/MSM.928931 |
_version_ | 1783608458078060544 |
---|---|
author | Wu, Yejun Li, Fangbing Wang, Yilin Hu, Tianxiang Xiao, Liang |
author_facet | Wu, Yejun Li, Fangbing Wang, Yilin Hu, Tianxiang Xiao, Liang |
author_sort | Wu, Yejun |
collection | PubMed |
description | BACKGROUND: Fat suppression is an important technique in magnetic resonance imaging (MRI). Comprehensive and quantitative assessment of the influence of fat suppression (FS) on T1-weighted imaging of intracranial vessel wall imaging is needed. In this study, we compared the three-dimensional (3D) variable-flip-angle turbo-spin-echo (CUBE) T1-weighted sequence with and without FS to investigate the differences between the 2 sequences in imaging of the middle cerebral artery (MCA) vessel walls. MATERIAL/METHODS: A 3D CUBE T1-weighted sequence with and without FS by 3.0T MRI was used to obtain intracranial vessel wall images of 105 MCA stenosis patients. The image signal intensity, signal-to-noise ratio, and contrast-to-noise ratio were calculated and compared. Two observers evaluated the image quality of the 2 sequences twice, and interobserver and intraobserver consistency were determined. Differences between the 2 sequences in the area of lumen and plaque were compared. RESULTS: The signal intensity, signal-to-noise ratio, and contrast-to-noise ratio of the 3D CUBE T1-weighted sequence without FS were higher, whereas the noise level was lower. In terms of subjective scores, the 3D CUBE T1-weighted sequence without FS performed better. No significant difference was observed in the measurement of the vascular lumen area between the 2 sequences, although there were statistically significant differences in the measurement of plaque area (i.e., the measurement obtained with 3D CUBE T1-weighted sequence without FS was larger). CONCLUSIONS: 3D CUBE T1-weighted sequence without FS performed better for MCA vessel walls imaging than 3D CUBE T1-weighted sequence with FS. |
format | Online Article Text |
id | pubmed-7657061 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-76570612020-11-17 High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression Wu, Yejun Li, Fangbing Wang, Yilin Hu, Tianxiang Xiao, Liang Med Sci Monit Clinical Research BACKGROUND: Fat suppression is an important technique in magnetic resonance imaging (MRI). Comprehensive and quantitative assessment of the influence of fat suppression (FS) on T1-weighted imaging of intracranial vessel wall imaging is needed. In this study, we compared the three-dimensional (3D) variable-flip-angle turbo-spin-echo (CUBE) T1-weighted sequence with and without FS to investigate the differences between the 2 sequences in imaging of the middle cerebral artery (MCA) vessel walls. MATERIAL/METHODS: A 3D CUBE T1-weighted sequence with and without FS by 3.0T MRI was used to obtain intracranial vessel wall images of 105 MCA stenosis patients. The image signal intensity, signal-to-noise ratio, and contrast-to-noise ratio were calculated and compared. Two observers evaluated the image quality of the 2 sequences twice, and interobserver and intraobserver consistency were determined. Differences between the 2 sequences in the area of lumen and plaque were compared. RESULTS: The signal intensity, signal-to-noise ratio, and contrast-to-noise ratio of the 3D CUBE T1-weighted sequence without FS were higher, whereas the noise level was lower. In terms of subjective scores, the 3D CUBE T1-weighted sequence without FS performed better. No significant difference was observed in the measurement of the vascular lumen area between the 2 sequences, although there were statistically significant differences in the measurement of plaque area (i.e., the measurement obtained with 3D CUBE T1-weighted sequence without FS was larger). CONCLUSIONS: 3D CUBE T1-weighted sequence without FS performed better for MCA vessel walls imaging than 3D CUBE T1-weighted sequence with FS. International Scientific Literature, Inc. 2020-11-07 /pmc/articles/PMC7657061/ /pubmed/33159730 http://dx.doi.org/10.12659/MSM.928931 Text en © Med Sci Monit, 2020 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Clinical Research Wu, Yejun Li, Fangbing Wang, Yilin Hu, Tianxiang Xiao, Liang High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression |
title | High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression |
title_full | High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression |
title_fullStr | High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression |
title_full_unstemmed | High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression |
title_short | High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression |
title_sort | high-resolution vessel wall magnetic resonance imaging of the middle cerebral artery: comparison of 3d cube t1-weighted sequence with and without fat suppression |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7657061/ https://www.ncbi.nlm.nih.gov/pubmed/33159730 http://dx.doi.org/10.12659/MSM.928931 |
work_keys_str_mv | AT wuyejun highresolutionvesselwallmagneticresonanceimagingofthemiddlecerebralarterycomparisonof3dcubet1weightedsequencewithandwithoutfatsuppression AT lifangbing highresolutionvesselwallmagneticresonanceimagingofthemiddlecerebralarterycomparisonof3dcubet1weightedsequencewithandwithoutfatsuppression AT wangyilin highresolutionvesselwallmagneticresonanceimagingofthemiddlecerebralarterycomparisonof3dcubet1weightedsequencewithandwithoutfatsuppression AT hutianxiang highresolutionvesselwallmagneticresonanceimagingofthemiddlecerebralarterycomparisonof3dcubet1weightedsequencewithandwithoutfatsuppression AT xiaoliang highresolutionvesselwallmagneticresonanceimagingofthemiddlecerebralarterycomparisonof3dcubet1weightedsequencewithandwithoutfatsuppression |