Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis
BACKGROUND: Transcatheter aortic valve replacement (TAVR), widely used as an alternative therapy in patients with severe aortic stenosis, is expected to be offered to low-risk patents with a longer life expectancy. The durability of transcatheter aortic valve is becoming of increasing importance. ME...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7657687/ https://www.ncbi.nlm.nih.gov/pubmed/33214775 http://dx.doi.org/10.1155/2020/4075792 |
_version_ | 1783608548054269952 |
---|---|
author | Long, Yu-Xiang Liu, Zeng-Zhang |
author_facet | Long, Yu-Xiang Liu, Zeng-Zhang |
author_sort | Long, Yu-Xiang |
collection | PubMed |
description | BACKGROUND: Transcatheter aortic valve replacement (TAVR), widely used as an alternative therapy in patients with severe aortic stenosis, is expected to be offered to low-risk patents with a longer life expectancy. The durability of transcatheter aortic valve is becoming of increasing importance. METHOD: PubMed, Embase, and Cochrane CENTRAL from the inception to March 2020 were systematically screened for studies reporting on structural valve deterioration (SVD) in TAVR patients. Incidence of SVD was diagnosed according to the latest European consensus as the primary end point. Predictors of SVD evaluated at multivariable analysis and cumulative incidence function (CIF) of SVD were the secondary end point. RESULT: Twelve studies encompassing 10031 patients evaluating the incidence of SVD were included, with a follow-up between 1 and 8 years. The pooled incidence of SVD was 4.93% (95% CI, 2.75%–7.70%, I(2) = 96%) at 1 year and 8.97% (95% CI, 6.89%–11.29%, I(2) = 86%) in the long term (≥5 years). Subgroup analysis was performed to identify the valve type that may result in partial heterogeneity. SVD was more frequent in patents with a valve diameter of <26 mm (HR: 3.57, 1.47–8.69), oral anticoagulants (OAC), exposure at discharge (OR: 0.48, 0.38–0.61), or by a disease of renal dysfunction (OR 1.42, 1.03–1.96). CONCLUSION: SVD represents infrequent events after TAVR in the long term (>5 years), occurring more commonly in renal dysfunction patients, with small valve diameter and without OAC exposure. There may be an underestimation of the incidence if we assume death as a competing risk. |
format | Online Article Text |
id | pubmed-7657687 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-76576872020-11-18 Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis Long, Yu-Xiang Liu, Zeng-Zhang J Interv Cardiol Research Article BACKGROUND: Transcatheter aortic valve replacement (TAVR), widely used as an alternative therapy in patients with severe aortic stenosis, is expected to be offered to low-risk patents with a longer life expectancy. The durability of transcatheter aortic valve is becoming of increasing importance. METHOD: PubMed, Embase, and Cochrane CENTRAL from the inception to March 2020 were systematically screened for studies reporting on structural valve deterioration (SVD) in TAVR patients. Incidence of SVD was diagnosed according to the latest European consensus as the primary end point. Predictors of SVD evaluated at multivariable analysis and cumulative incidence function (CIF) of SVD were the secondary end point. RESULT: Twelve studies encompassing 10031 patients evaluating the incidence of SVD were included, with a follow-up between 1 and 8 years. The pooled incidence of SVD was 4.93% (95% CI, 2.75%–7.70%, I(2) = 96%) at 1 year and 8.97% (95% CI, 6.89%–11.29%, I(2) = 86%) in the long term (≥5 years). Subgroup analysis was performed to identify the valve type that may result in partial heterogeneity. SVD was more frequent in patents with a valve diameter of <26 mm (HR: 3.57, 1.47–8.69), oral anticoagulants (OAC), exposure at discharge (OR: 0.48, 0.38–0.61), or by a disease of renal dysfunction (OR 1.42, 1.03–1.96). CONCLUSION: SVD represents infrequent events after TAVR in the long term (>5 years), occurring more commonly in renal dysfunction patients, with small valve diameter and without OAC exposure. There may be an underestimation of the incidence if we assume death as a competing risk. Hindawi 2020-11-04 /pmc/articles/PMC7657687/ /pubmed/33214775 http://dx.doi.org/10.1155/2020/4075792 Text en Copyright © 2020 Yu-Xiang Long and Zeng-Zhang Liu. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Long, Yu-Xiang Liu, Zeng-Zhang Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis |
title | Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis |
title_full | Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis |
title_fullStr | Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis |
title_short | Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis |
title_sort | incidence and predictors of structural valve deterioration after transcatheter aortic valve replacement: a systematic review and meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7657687/ https://www.ncbi.nlm.nih.gov/pubmed/33214775 http://dx.doi.org/10.1155/2020/4075792 |
work_keys_str_mv | AT longyuxiang incidenceandpredictorsofstructuralvalvedeteriorationaftertranscatheteraorticvalvereplacementasystematicreviewandmetaanalysis AT liuzengzhang incidenceandpredictorsofstructuralvalvedeteriorationaftertranscatheteraorticvalvereplacementasystematicreviewandmetaanalysis |