A Novel Technique of Arthroscopic Ankle Lateral Ligament Repair Using a Knotless Suture Anchor

BACKGROUND: Although arthroscopic lateral ligament repair (ALLR) with suture anchors for chronic lateral ankle instability has become widely accepted, some complications have been reported as well. Establishment of a new technique is essential for better clinical outcomes after ALLR. PURPOSE: To rep...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanzaki, Noriyuki, Chinzei, Nobuaki, Yamashita, Takahiro, Kumai, Tsukasa, Kuroda, Ryosuke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7658529/
https://www.ncbi.nlm.nih.gov/pubmed/33225007
http://dx.doi.org/10.1177/2325967120962079
_version_ 1783608691241517056
author Kanzaki, Noriyuki
Chinzei, Nobuaki
Yamashita, Takahiro
Kumai, Tsukasa
Kuroda, Ryosuke
author_facet Kanzaki, Noriyuki
Chinzei, Nobuaki
Yamashita, Takahiro
Kumai, Tsukasa
Kuroda, Ryosuke
author_sort Kanzaki, Noriyuki
collection PubMed
description BACKGROUND: Although arthroscopic lateral ligament repair (ALLR) with suture anchors for chronic lateral ankle instability has become widely accepted, some complications have been reported as well. Establishment of a new technique is essential for better clinical outcomes after ALLR. PURPOSE: To report a novel technique and good clinical results of ALLR using a knotless suture anchor. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: We examined 30 patients (16 men and 14 women) who underwent ALLR. The mean age of the patients was 30.0 years, and the average period of postoperative monitoring was 21 months. The Japanese Society for Surgery of the Foot (JSSF) ankle-hindfoot scale was used for clinical evaluation postoperatively, and the Self-Administered Foot Evaluation Questionnaire (SAFE-Q) for patient-reported results. Surgical complications were also examined. RESULTS: The JSSF ankle-hindfoot scale showed a significant improvement from preoperatively to follow-up (from 72.1 to 96.1; P < 0.001), and the SAFE-Q was significantly improved in all subscales (pain and pain-related, physical function and daily living, social function, shoe-related, and general health and well-being; P < 0.004 for all). Complications included residual joint pain due to remaining osteophytes in 1 case, scar pain of the accessory anterolateral portal in 2 cases, and positive Tinel sign indicative of superficial peroneal nerve irritation at the anterolateral portal in 1 case. CONCLUSION: The clinical results of the novel ALLR technique were overall satisfactory. Knot-related complications, one of the main reasons for postoperative complications, were reduced by using a knotless suture anchor.
format Online
Article
Text
id pubmed-7658529
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-76585292020-11-20 A Novel Technique of Arthroscopic Ankle Lateral Ligament Repair Using a Knotless Suture Anchor Kanzaki, Noriyuki Chinzei, Nobuaki Yamashita, Takahiro Kumai, Tsukasa Kuroda, Ryosuke Orthop J Sports Med Article BACKGROUND: Although arthroscopic lateral ligament repair (ALLR) with suture anchors for chronic lateral ankle instability has become widely accepted, some complications have been reported as well. Establishment of a new technique is essential for better clinical outcomes after ALLR. PURPOSE: To report a novel technique and good clinical results of ALLR using a knotless suture anchor. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: We examined 30 patients (16 men and 14 women) who underwent ALLR. The mean age of the patients was 30.0 years, and the average period of postoperative monitoring was 21 months. The Japanese Society for Surgery of the Foot (JSSF) ankle-hindfoot scale was used for clinical evaluation postoperatively, and the Self-Administered Foot Evaluation Questionnaire (SAFE-Q) for patient-reported results. Surgical complications were also examined. RESULTS: The JSSF ankle-hindfoot scale showed a significant improvement from preoperatively to follow-up (from 72.1 to 96.1; P < 0.001), and the SAFE-Q was significantly improved in all subscales (pain and pain-related, physical function and daily living, social function, shoe-related, and general health and well-being; P < 0.004 for all). Complications included residual joint pain due to remaining osteophytes in 1 case, scar pain of the accessory anterolateral portal in 2 cases, and positive Tinel sign indicative of superficial peroneal nerve irritation at the anterolateral portal in 1 case. CONCLUSION: The clinical results of the novel ALLR technique were overall satisfactory. Knot-related complications, one of the main reasons for postoperative complications, were reduced by using a knotless suture anchor. SAGE Publications 2020-11-09 /pmc/articles/PMC7658529/ /pubmed/33225007 http://dx.doi.org/10.1177/2325967120962079 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Kanzaki, Noriyuki
Chinzei, Nobuaki
Yamashita, Takahiro
Kumai, Tsukasa
Kuroda, Ryosuke
A Novel Technique of Arthroscopic Ankle Lateral Ligament Repair Using a Knotless Suture Anchor
title A Novel Technique of Arthroscopic Ankle Lateral Ligament Repair Using a Knotless Suture Anchor
title_full A Novel Technique of Arthroscopic Ankle Lateral Ligament Repair Using a Knotless Suture Anchor
title_fullStr A Novel Technique of Arthroscopic Ankle Lateral Ligament Repair Using a Knotless Suture Anchor
title_full_unstemmed A Novel Technique of Arthroscopic Ankle Lateral Ligament Repair Using a Knotless Suture Anchor
title_short A Novel Technique of Arthroscopic Ankle Lateral Ligament Repair Using a Knotless Suture Anchor
title_sort novel technique of arthroscopic ankle lateral ligament repair using a knotless suture anchor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7658529/
https://www.ncbi.nlm.nih.gov/pubmed/33225007
http://dx.doi.org/10.1177/2325967120962079
work_keys_str_mv AT kanzakinoriyuki anoveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT chinzeinobuaki anoveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT yamashitatakahiro anoveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT kumaitsukasa anoveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT kurodaryosuke anoveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT kanzakinoriyuki noveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT chinzeinobuaki noveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT yamashitatakahiro noveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT kumaitsukasa noveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor
AT kurodaryosuke noveltechniqueofarthroscopicanklelateralligamentrepairusingaknotlesssutureanchor