Cargando…

Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial

BACKGROUND: Myoglobin clearance in acute kidney injury requiring renal replacement therapy is important because myoglobin has direct renal toxic effects. Clinical data comparing different modalities of renal replacement therapy addressing myoglobin clearance are limited. This study aimed to compare...

Descripción completa

Detalles Bibliográficos
Autores principales: Weidhase, Lorenz, de Fallois, Jonathan, Haußig, Elena, Kaiser, Thorsten, Mende, Meinhard, Petros, Sirak
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7659077/
https://www.ncbi.nlm.nih.gov/pubmed/33176824
http://dx.doi.org/10.1186/s13054-020-03366-8
_version_ 1783608785101651968
author Weidhase, Lorenz
de Fallois, Jonathan
Haußig, Elena
Kaiser, Thorsten
Mende, Meinhard
Petros, Sirak
author_facet Weidhase, Lorenz
de Fallois, Jonathan
Haußig, Elena
Kaiser, Thorsten
Mende, Meinhard
Petros, Sirak
author_sort Weidhase, Lorenz
collection PubMed
description BACKGROUND: Myoglobin clearance in acute kidney injury requiring renal replacement therapy is important because myoglobin has direct renal toxic effects. Clinical data comparing different modalities of renal replacement therapy addressing myoglobin clearance are limited. This study aimed to compare two renal replacement modalities regarding myoglobin clearance. METHODS: In this prospective, randomized, single-blinded, single-center trial, 70 critically ill patients requiring renal replacement therapy were randomized 1:1 into an intervention arm using continuous veno-venous hemodialysis with high cutoff dialyzer and a control arm using continuous veno-venous hemodiafiltration postdilution with high-flux dialyzer. Regional citrate anticoagulation was used in both groups to maintain the extracorporeal circuit. The concentrations of myoglobin, urea, creatinine, β2-microglobulin, interleukin-6 and albumin were measured before and after the dialyzer at 1 h, 6 h, 12 h, 24 h and 48 h after initiating continuous renal replacement therapy. RESULTS: Thirty-three patients were allocated to the control arm (CVVHDF with high-flux dialyzer) and 35 patients to the intervention arm (CVVHD with high cutoff dialyzer). Myoglobin clearance, as a primary endpoint, was significantly better in the intervention arm than in the control arm throughout the whole study period. The clearance values for urea and creatinine were higher in the control arm. There was no measurable albumin clearance in both arms. The clearance data for β(2)-microglobulin and interleukin-6 were non-inferior in the intervention arm compared to those for the control arm. Dialyzer lifespan was 57.0 [38.0, 72.0] hours in the control arm and 70.0 [56.75, 72.0] hours in the intervention arm (p = 0.029). CONCLUSIONS: Myoglobin clearance using continuous veno-venous hemodialysis with high cutoff dialyzer and regional citrate anticoagulation is better than that with continuous veno-venous hemodiafiltration with regional citrate anticoagulation. TRIAL REGISTRATION: German Clinical Trials Registry (DRKS00012407); date of registration 23/05/2017. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00012407.
format Online
Article
Text
id pubmed-7659077
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-76590772020-11-13 Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial Weidhase, Lorenz de Fallois, Jonathan Haußig, Elena Kaiser, Thorsten Mende, Meinhard Petros, Sirak Crit Care Research BACKGROUND: Myoglobin clearance in acute kidney injury requiring renal replacement therapy is important because myoglobin has direct renal toxic effects. Clinical data comparing different modalities of renal replacement therapy addressing myoglobin clearance are limited. This study aimed to compare two renal replacement modalities regarding myoglobin clearance. METHODS: In this prospective, randomized, single-blinded, single-center trial, 70 critically ill patients requiring renal replacement therapy were randomized 1:1 into an intervention arm using continuous veno-venous hemodialysis with high cutoff dialyzer and a control arm using continuous veno-venous hemodiafiltration postdilution with high-flux dialyzer. Regional citrate anticoagulation was used in both groups to maintain the extracorporeal circuit. The concentrations of myoglobin, urea, creatinine, β2-microglobulin, interleukin-6 and albumin were measured before and after the dialyzer at 1 h, 6 h, 12 h, 24 h and 48 h after initiating continuous renal replacement therapy. RESULTS: Thirty-three patients were allocated to the control arm (CVVHDF with high-flux dialyzer) and 35 patients to the intervention arm (CVVHD with high cutoff dialyzer). Myoglobin clearance, as a primary endpoint, was significantly better in the intervention arm than in the control arm throughout the whole study period. The clearance values for urea and creatinine were higher in the control arm. There was no measurable albumin clearance in both arms. The clearance data for β(2)-microglobulin and interleukin-6 were non-inferior in the intervention arm compared to those for the control arm. Dialyzer lifespan was 57.0 [38.0, 72.0] hours in the control arm and 70.0 [56.75, 72.0] hours in the intervention arm (p = 0.029). CONCLUSIONS: Myoglobin clearance using continuous veno-venous hemodialysis with high cutoff dialyzer and regional citrate anticoagulation is better than that with continuous veno-venous hemodiafiltration with regional citrate anticoagulation. TRIAL REGISTRATION: German Clinical Trials Registry (DRKS00012407); date of registration 23/05/2017. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00012407. BioMed Central 2020-11-11 /pmc/articles/PMC7659077/ /pubmed/33176824 http://dx.doi.org/10.1186/s13054-020-03366-8 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Weidhase, Lorenz
de Fallois, Jonathan
Haußig, Elena
Kaiser, Thorsten
Mende, Meinhard
Petros, Sirak
Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial
title Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial
title_full Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial
title_fullStr Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial
title_full_unstemmed Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial
title_short Myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial
title_sort myoglobin clearance with continuous veno-venous hemodialysis using high cutoff dialyzer versus continuous veno-venous hemodiafiltration using high-flux dialyzer: a prospective randomized controlled trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7659077/
https://www.ncbi.nlm.nih.gov/pubmed/33176824
http://dx.doi.org/10.1186/s13054-020-03366-8
work_keys_str_mv AT weidhaselorenz myoglobinclearancewithcontinuousvenovenoushemodialysisusinghighcutoffdialyzerversuscontinuousvenovenoushemodiafiltrationusinghighfluxdialyzeraprospectiverandomizedcontrolledtrial
AT defalloisjonathan myoglobinclearancewithcontinuousvenovenoushemodialysisusinghighcutoffdialyzerversuscontinuousvenovenoushemodiafiltrationusinghighfluxdialyzeraprospectiverandomizedcontrolledtrial
AT haußigelena myoglobinclearancewithcontinuousvenovenoushemodialysisusinghighcutoffdialyzerversuscontinuousvenovenoushemodiafiltrationusinghighfluxdialyzeraprospectiverandomizedcontrolledtrial
AT kaiserthorsten myoglobinclearancewithcontinuousvenovenoushemodialysisusinghighcutoffdialyzerversuscontinuousvenovenoushemodiafiltrationusinghighfluxdialyzeraprospectiverandomizedcontrolledtrial
AT mendemeinhard myoglobinclearancewithcontinuousvenovenoushemodialysisusinghighcutoffdialyzerversuscontinuousvenovenoushemodiafiltrationusinghighfluxdialyzeraprospectiverandomizedcontrolledtrial
AT petrossirak myoglobinclearancewithcontinuousvenovenoushemodialysisusinghighcutoffdialyzerversuscontinuousvenovenoushemodiafiltrationusinghighfluxdialyzeraprospectiverandomizedcontrolledtrial