Cargando…
Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry
Extracellular vesicles (EVs) play a crucial role in the intercellular crosstalk. Mesenchymal stem cell-derived EVs (MSC-EVs), displaying promising therapeutic roles, contribute to the strong rationale for developing EVs as an alternative therapeutic option. EV analysis still represents one of the ma...
Autores principales: | , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7660682/ https://www.ncbi.nlm.nih.gov/pubmed/33114229 http://dx.doi.org/10.3390/ijms21217885 |
_version_ | 1783609056764624896 |
---|---|
author | Simeone, Pasquale Celia, Christian Bologna, Giuseppina Ercolino, Eva Pierdomenico, Laura Cilurzo, Felisa Grande, Rossella Diomede, Francesca Vespa, Simone Canonico, Barbara Guescini, Michele Stocchi, Vilberto Lotti, Lavinia Vittoria Guagnano, Maria Teresa Stellin, Luisa Papa, Stefano Trubiani, Oriana Marchisio, Marco Miscia, Sebastiano Lanuti, Paola |
author_facet | Simeone, Pasquale Celia, Christian Bologna, Giuseppina Ercolino, Eva Pierdomenico, Laura Cilurzo, Felisa Grande, Rossella Diomede, Francesca Vespa, Simone Canonico, Barbara Guescini, Michele Stocchi, Vilberto Lotti, Lavinia Vittoria Guagnano, Maria Teresa Stellin, Luisa Papa, Stefano Trubiani, Oriana Marchisio, Marco Miscia, Sebastiano Lanuti, Paola |
author_sort | Simeone, Pasquale |
collection | PubMed |
description | Extracellular vesicles (EVs) play a crucial role in the intercellular crosstalk. Mesenchymal stem cell-derived EVs (MSC-EVs), displaying promising therapeutic roles, contribute to the strong rationale for developing EVs as an alternative therapeutic option. EV analysis still represents one of the major issues to be solved in order to translate the use of MSC-EV detection in clinical settings. Even if flow cytometry (FC) has been largely applied for EV studies, the lack of consensus on protocols for FC detection of EVs generated controversy. Standard FC procedures, based on scatter measurements, only allows the detection of the “tip of the iceberg” of all EVs. We applied an alternative FC approach based on the use of a trigger threshold on a fluorescence channel. The EV numbers obtained by the application of the fluorescence triggering resulted significantly higher in respect to them obtained from the same samples acquired by placing the threshold on the side scatter (SSC) channel. The analysis of EV concentrations carried out by three different standardized flow cytometers allowed us to achieve a high level of reproducibility (CV < 20%). By applying the here-reported method highly reproducible results in terms of EV analysis and concentration measurements were obtained. |
format | Online Article Text |
id | pubmed-7660682 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76606822020-11-13 Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry Simeone, Pasquale Celia, Christian Bologna, Giuseppina Ercolino, Eva Pierdomenico, Laura Cilurzo, Felisa Grande, Rossella Diomede, Francesca Vespa, Simone Canonico, Barbara Guescini, Michele Stocchi, Vilberto Lotti, Lavinia Vittoria Guagnano, Maria Teresa Stellin, Luisa Papa, Stefano Trubiani, Oriana Marchisio, Marco Miscia, Sebastiano Lanuti, Paola Int J Mol Sci Article Extracellular vesicles (EVs) play a crucial role in the intercellular crosstalk. Mesenchymal stem cell-derived EVs (MSC-EVs), displaying promising therapeutic roles, contribute to the strong rationale for developing EVs as an alternative therapeutic option. EV analysis still represents one of the major issues to be solved in order to translate the use of MSC-EV detection in clinical settings. Even if flow cytometry (FC) has been largely applied for EV studies, the lack of consensus on protocols for FC detection of EVs generated controversy. Standard FC procedures, based on scatter measurements, only allows the detection of the “tip of the iceberg” of all EVs. We applied an alternative FC approach based on the use of a trigger threshold on a fluorescence channel. The EV numbers obtained by the application of the fluorescence triggering resulted significantly higher in respect to them obtained from the same samples acquired by placing the threshold on the side scatter (SSC) channel. The analysis of EV concentrations carried out by three different standardized flow cytometers allowed us to achieve a high level of reproducibility (CV < 20%). By applying the here-reported method highly reproducible results in terms of EV analysis and concentration measurements were obtained. MDPI 2020-10-23 /pmc/articles/PMC7660682/ /pubmed/33114229 http://dx.doi.org/10.3390/ijms21217885 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Simeone, Pasquale Celia, Christian Bologna, Giuseppina Ercolino, Eva Pierdomenico, Laura Cilurzo, Felisa Grande, Rossella Diomede, Francesca Vespa, Simone Canonico, Barbara Guescini, Michele Stocchi, Vilberto Lotti, Lavinia Vittoria Guagnano, Maria Teresa Stellin, Luisa Papa, Stefano Trubiani, Oriana Marchisio, Marco Miscia, Sebastiano Lanuti, Paola Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry |
title | Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry |
title_full | Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry |
title_fullStr | Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry |
title_full_unstemmed | Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry |
title_short | Diameters and Fluorescence Calibration for Extracellular Vesicle Analyses by Flow Cytometry |
title_sort | diameters and fluorescence calibration for extracellular vesicle analyses by flow cytometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7660682/ https://www.ncbi.nlm.nih.gov/pubmed/33114229 http://dx.doi.org/10.3390/ijms21217885 |
work_keys_str_mv | AT simeonepasquale diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT celiachristian diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT bolognagiuseppina diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT ercolinoeva diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT pierdomenicolaura diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT cilurzofelisa diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT granderossella diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT diomedefrancesca diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT vespasimone diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT canonicobarbara diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT guescinimichele diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT stocchivilberto diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT lottilaviniavittoria diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT guagnanomariateresa diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT stellinluisa diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT papastefano diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT trubianioriana diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT marchisiomarco diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT misciasebastiano diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry AT lanutipaola diametersandfluorescencecalibrationforextracellularvesicleanalysesbyflowcytometry |