Cargando…

Adherence to Antihypertensive Drugs Assessed by Hyphenated High‐Resolution Mass Spectrometry Analysis of Oral Fluids

BACKGROUND: It is currently unknown if antihypertensive drugs can be monitored in oral fluid (OF) using liquid chromatography coupled to high‐resolution mass spectrometry. METHODS AND RESULTS: We assessed adherence using liquid chromatography coupled to high‐resolution mass spectrometry in OF, plasm...

Descripción completa

Detalles Bibliográficos
Autores principales: Lauder, Lucas, Ewen, Sebastian, Kunz, Michael, Richter, Lilian H. J., Jacobs, Cathy M., Kindermann, Ingrid, Böhm, Michael, Meyer, Markus R., Mahfoud, Felix
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7660713/
https://www.ncbi.nlm.nih.gov/pubmed/32633188
http://dx.doi.org/10.1161/JAHA.119.014180
_version_ 1783609064122482688
author Lauder, Lucas
Ewen, Sebastian
Kunz, Michael
Richter, Lilian H. J.
Jacobs, Cathy M.
Kindermann, Ingrid
Böhm, Michael
Meyer, Markus R.
Mahfoud, Felix
author_facet Lauder, Lucas
Ewen, Sebastian
Kunz, Michael
Richter, Lilian H. J.
Jacobs, Cathy M.
Kindermann, Ingrid
Böhm, Michael
Meyer, Markus R.
Mahfoud, Felix
author_sort Lauder, Lucas
collection PubMed
description BACKGROUND: It is currently unknown if antihypertensive drugs can be monitored in oral fluid (OF) using liquid chromatography coupled to high‐resolution mass spectrometry. METHODS AND RESULTS: We assessed adherence using liquid chromatography coupled to high‐resolution mass spectrometry in OF, plasma, and urine of 56 consecutive patients with hypertension referred to a tertiary hypertension unit. Of these patients, 59% were completely adherent (all drugs detectable in urine), whereas 29% and 13% were partially adherent (1 drug not detectable in urine) or nonadherent (>1 drug not detectable in urine), respectively. Adherent patients were on fewer antihypertensive drugs (P=0.001), had fewer daily drug doses (P=0.012), and had lower 24‐hour ambulatory systolic (P=0.012) and diastolic (P=0.009) blood pressures than nonadherent or partially adherent patients. Most drugs were detected in urine compared with plasma and OF (181 versus 119 versus 88; P=0.001). Compared with urine and plasma, detection rates of angiotensin‐converting enzyme inhibitors, angiotensin II receptor blockers, and diuretics were lower in OF. There was no difference in the frequency of detecting β blockers (P=1.0) and calcium channel blockers (P=0.063) when comparing OF with urine. There was no difference in the number of calcium channel blockers (P=0.727), β blockers (P=1.000), thiazide diuretics (P=0.125), and α‐2 agonists (P=0.125) identified between OF and plasma. CONCLUSIONS: This study shows the feasibility of drug adherence testing for several antihypertensive drugs, especially those without acidic components, in OF, with a similar recovery compared with plasma. Therefore, drug adherence testing in OF should be further explored as a noninvasive approach, which can easily be performed in an “out‐of‐office” setting.
format Online
Article
Text
id pubmed-7660713
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-76607132020-11-17 Adherence to Antihypertensive Drugs Assessed by Hyphenated High‐Resolution Mass Spectrometry Analysis of Oral Fluids Lauder, Lucas Ewen, Sebastian Kunz, Michael Richter, Lilian H. J. Jacobs, Cathy M. Kindermann, Ingrid Böhm, Michael Meyer, Markus R. Mahfoud, Felix J Am Heart Assoc Original Research BACKGROUND: It is currently unknown if antihypertensive drugs can be monitored in oral fluid (OF) using liquid chromatography coupled to high‐resolution mass spectrometry. METHODS AND RESULTS: We assessed adherence using liquid chromatography coupled to high‐resolution mass spectrometry in OF, plasma, and urine of 56 consecutive patients with hypertension referred to a tertiary hypertension unit. Of these patients, 59% were completely adherent (all drugs detectable in urine), whereas 29% and 13% were partially adherent (1 drug not detectable in urine) or nonadherent (>1 drug not detectable in urine), respectively. Adherent patients were on fewer antihypertensive drugs (P=0.001), had fewer daily drug doses (P=0.012), and had lower 24‐hour ambulatory systolic (P=0.012) and diastolic (P=0.009) blood pressures than nonadherent or partially adherent patients. Most drugs were detected in urine compared with plasma and OF (181 versus 119 versus 88; P=0.001). Compared with urine and plasma, detection rates of angiotensin‐converting enzyme inhibitors, angiotensin II receptor blockers, and diuretics were lower in OF. There was no difference in the frequency of detecting β blockers (P=1.0) and calcium channel blockers (P=0.063) when comparing OF with urine. There was no difference in the number of calcium channel blockers (P=0.727), β blockers (P=1.000), thiazide diuretics (P=0.125), and α‐2 agonists (P=0.125) identified between OF and plasma. CONCLUSIONS: This study shows the feasibility of drug adherence testing for several antihypertensive drugs, especially those without acidic components, in OF, with a similar recovery compared with plasma. Therefore, drug adherence testing in OF should be further explored as a noninvasive approach, which can easily be performed in an “out‐of‐office” setting. John Wiley and Sons Inc. 2020-07-07 /pmc/articles/PMC7660713/ /pubmed/32633188 http://dx.doi.org/10.1161/JAHA.119.014180 Text en © 2020 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Research
Lauder, Lucas
Ewen, Sebastian
Kunz, Michael
Richter, Lilian H. J.
Jacobs, Cathy M.
Kindermann, Ingrid
Böhm, Michael
Meyer, Markus R.
Mahfoud, Felix
Adherence to Antihypertensive Drugs Assessed by Hyphenated High‐Resolution Mass Spectrometry Analysis of Oral Fluids
title Adherence to Antihypertensive Drugs Assessed by Hyphenated High‐Resolution Mass Spectrometry Analysis of Oral Fluids
title_full Adherence to Antihypertensive Drugs Assessed by Hyphenated High‐Resolution Mass Spectrometry Analysis of Oral Fluids
title_fullStr Adherence to Antihypertensive Drugs Assessed by Hyphenated High‐Resolution Mass Spectrometry Analysis of Oral Fluids
title_full_unstemmed Adherence to Antihypertensive Drugs Assessed by Hyphenated High‐Resolution Mass Spectrometry Analysis of Oral Fluids
title_short Adherence to Antihypertensive Drugs Assessed by Hyphenated High‐Resolution Mass Spectrometry Analysis of Oral Fluids
title_sort adherence to antihypertensive drugs assessed by hyphenated high‐resolution mass spectrometry analysis of oral fluids
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7660713/
https://www.ncbi.nlm.nih.gov/pubmed/32633188
http://dx.doi.org/10.1161/JAHA.119.014180
work_keys_str_mv AT lauderlucas adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids
AT ewensebastian adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids
AT kunzmichael adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids
AT richterlilianhj adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids
AT jacobscathym adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids
AT kindermanningrid adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids
AT bohmmichael adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids
AT meyermarkusr adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids
AT mahfoudfelix adherencetoantihypertensivedrugsassessedbyhyphenatedhighresolutionmassspectrometryanalysisoforalfluids