Cargando…
Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography
BACKGROUND: Assessment of the interatrial septum (IAS) has become an attractive area of interest for a variety of important interventional procedures. Newer imaging modalities like multi-slice computed tomography (MSCT) and cardiac MRI (CMR) can provide higher resolution and wider field of view than...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7661592/ https://www.ncbi.nlm.nih.gov/pubmed/33180202 http://dx.doi.org/10.1186/s43044-020-00109-6 |
_version_ | 1783609236239941632 |
---|---|
author | Elagha, Abdalla Othman, Yaseen Darweesh, Reham Awadein, Ghada Hashad, Assem |
author_facet | Elagha, Abdalla Othman, Yaseen Darweesh, Reham Awadein, Ghada Hashad, Assem |
author_sort | Elagha, Abdalla |
collection | PubMed |
description | BACKGROUND: Assessment of the interatrial septum (IAS) has become an attractive area of interest for a variety of important interventional procedures. Newer imaging modalities like multi-slice computed tomography (MSCT) and cardiac MRI (CMR) can provide higher resolution and wider field of view than echocardiography. Moreover, high-field (3-Tesla) CMR can even enhance spatial and temporal resolution. The characteristics of the interatrial septum were retrospectively studied in 371 consecutive subjects (201 men, 31–73 years old) in whom MSCT was performed primarily for non-invasive evaluation of the coronary arteries. All subjects underwent both MSCT and MRI scans within 0–30 day’s interval. A 3D volume covering the whole heart was acquired across the heart with and without contrast enhancement. Also, patients underwent cardiac MSCT examinations using 64-row MSCT scanners. RESULTS: The mean scan time of MSCT was 10.4 ± 2.8 s and 9.7 ± 2.9 min for CMR. The mean length of IAS by CMR and CT was 39.65 ± 4.6 mm and 39.28 ± 4.7 mm, respectively. The mean maximal thickness of IAS by CMR and CT was 3.1 ± 0.97 mm and 3.15 ± 0.95 mm, respectively. The mean thickness of fossa ovalis by CMR and CT was 1.04 ± 0.36 mm and 1.04 ± 0.44 mm, respectively. The mean length of fossa ovalis by CMR and CT was 12.8 ± 3.7 mm and 12.8 ± 3.5 mm, respectively. Finally, the mean angle of IAS by CMR and CT was identical (155 ± 9.2°). Measurements of various morphological features of IAS showed no statistically significant difference between CMR and CT, with an excellent correlation and close relationship regarding IAS length, maximal IAS thickness, fossa ovalis thickness, fossa ovalis length, and IAS angle (r = 0.98, 0.98, 0.95, 0.96, and 0.92, respectively). CONCLUSION: Whole-heart 3D acquisition at 3-T MRI using a free-breathing technique provides a valuable non-invasive imaging tool for excellent assessment of the interatrial septum—as compared to MSCT—that may have significant clinical implication for diagnostic purposes and therapeutic interventional procedures, as it may facilitate planning, improve outcome, and shorten its duration. |
format | Online Article Text |
id | pubmed-7661592 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-76615922020-11-20 Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography Elagha, Abdalla Othman, Yaseen Darweesh, Reham Awadein, Ghada Hashad, Assem Egypt Heart J Research BACKGROUND: Assessment of the interatrial septum (IAS) has become an attractive area of interest for a variety of important interventional procedures. Newer imaging modalities like multi-slice computed tomography (MSCT) and cardiac MRI (CMR) can provide higher resolution and wider field of view than echocardiography. Moreover, high-field (3-Tesla) CMR can even enhance spatial and temporal resolution. The characteristics of the interatrial septum were retrospectively studied in 371 consecutive subjects (201 men, 31–73 years old) in whom MSCT was performed primarily for non-invasive evaluation of the coronary arteries. All subjects underwent both MSCT and MRI scans within 0–30 day’s interval. A 3D volume covering the whole heart was acquired across the heart with and without contrast enhancement. Also, patients underwent cardiac MSCT examinations using 64-row MSCT scanners. RESULTS: The mean scan time of MSCT was 10.4 ± 2.8 s and 9.7 ± 2.9 min for CMR. The mean length of IAS by CMR and CT was 39.65 ± 4.6 mm and 39.28 ± 4.7 mm, respectively. The mean maximal thickness of IAS by CMR and CT was 3.1 ± 0.97 mm and 3.15 ± 0.95 mm, respectively. The mean thickness of fossa ovalis by CMR and CT was 1.04 ± 0.36 mm and 1.04 ± 0.44 mm, respectively. The mean length of fossa ovalis by CMR and CT was 12.8 ± 3.7 mm and 12.8 ± 3.5 mm, respectively. Finally, the mean angle of IAS by CMR and CT was identical (155 ± 9.2°). Measurements of various morphological features of IAS showed no statistically significant difference between CMR and CT, with an excellent correlation and close relationship regarding IAS length, maximal IAS thickness, fossa ovalis thickness, fossa ovalis length, and IAS angle (r = 0.98, 0.98, 0.95, 0.96, and 0.92, respectively). CONCLUSION: Whole-heart 3D acquisition at 3-T MRI using a free-breathing technique provides a valuable non-invasive imaging tool for excellent assessment of the interatrial septum—as compared to MSCT—that may have significant clinical implication for diagnostic purposes and therapeutic interventional procedures, as it may facilitate planning, improve outcome, and shorten its duration. Springer Berlin Heidelberg 2020-11-12 /pmc/articles/PMC7661592/ /pubmed/33180202 http://dx.doi.org/10.1186/s43044-020-00109-6 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Research Elagha, Abdalla Othman, Yaseen Darweesh, Reham Awadein, Ghada Hashad, Assem Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography |
title | Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography |
title_full | Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography |
title_fullStr | Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography |
title_full_unstemmed | Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography |
title_short | Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography |
title_sort | characterization of the interatrial septum by high-field cardiac mri: a comparison with multi-slice computed tomography |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7661592/ https://www.ncbi.nlm.nih.gov/pubmed/33180202 http://dx.doi.org/10.1186/s43044-020-00109-6 |
work_keys_str_mv | AT elaghaabdalla characterizationoftheinteratrialseptumbyhighfieldcardiacmriacomparisonwithmultislicecomputedtomography AT othmanyaseen characterizationoftheinteratrialseptumbyhighfieldcardiacmriacomparisonwithmultislicecomputedtomography AT darweeshreham characterizationoftheinteratrialseptumbyhighfieldcardiacmriacomparisonwithmultislicecomputedtomography AT awadeinghada characterizationoftheinteratrialseptumbyhighfieldcardiacmriacomparisonwithmultislicecomputedtomography AT hashadassem characterizationoftheinteratrialseptumbyhighfieldcardiacmriacomparisonwithmultislicecomputedtomography |