Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement

BACKGROUND: In the era of an expanding use of transcatheter aortic valve replacement (TAVR), conduction disturbances and the requirement for permanent pacemaker (PPM) implantation remains a clinical concern. HYPOTHESIS: Using a single‐center experience, we sought to identify predictors of ventricula...

Descripción completa

Detalles Bibliográficos
Autores principales: Elzeneini, Mohammed, Assaf, Yazan, Aalaei‐Andabili, Seyed Hossein, Mahmoud, Ahmad, Hamburger, Robert, Goel, Ramil, Bavry, Anthony A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wiley Periodicals, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7661645/
https://www.ncbi.nlm.nih.gov/pubmed/32886389
http://dx.doi.org/10.1002/clc.23447
_version_ 1783609240702681088
author Elzeneini, Mohammed
Assaf, Yazan
Aalaei‐Andabili, Seyed Hossein
Mahmoud, Ahmad
Hamburger, Robert
Goel, Ramil
Bavry, Anthony A
author_facet Elzeneini, Mohammed
Assaf, Yazan
Aalaei‐Andabili, Seyed Hossein
Mahmoud, Ahmad
Hamburger, Robert
Goel, Ramil
Bavry, Anthony A
author_sort Elzeneini, Mohammed
collection PubMed
description BACKGROUND: In the era of an expanding use of transcatheter aortic valve replacement (TAVR), conduction disturbances and the requirement for permanent pacemaker (PPM) implantation remains a clinical concern. HYPOTHESIS: Using a single‐center experience, we sought to identify predictors of ventricular pacing burden after TAVR in patients who required PPM implantation. METHODS: We conducted a retrospective study of 359 consecutive patients with symptomatic severe aortic valve stenosis who underwent TAVR at our institution between September 2013 and July 2019. Thirty patients (8.4%) required a PPM within 30 days after TAVR. Pre and post‐TAVR electrocardiograms, pre‐TAVR echocardiograms and computed tomography (CT), TAVR procedural details and post‐TAVR device interrogation records at 1, 3, and 6 months were reviewed. RESULTS: Mean percentage of ventricular pacing (VP%) at 1, 3, and 6 months was 58%, 59%, and 56% respectively. Using univariate logistic regression analysis, patients who had low VP% < 5% at 6 months were more likely to have a prosthesis/echocardiography‐derived left ventricular outflow tract (LVOT) diameter ratio < 1.3 (OR 7.00, P‐value .048), prosthesis/CT‐derived aortic annulus diameter ratio < 1.02 (OR 7.11, P‐value .047), post‐TAVR new‐onset LBBB (OR 16.80, P‐value .019), time to PPM implantation greater than 2 days post‐TAVR (OR 9.38, P‐value .026) and pre‐TAVR use of a beta blocker (OR 9.40, P‐value .026). CONCLUSIONS: In patients who required a PPM implantation post‐TAVR, a lower TAVR prosthesis/LVOT or aortic annulus diameter ratio, post‐TAVR new‐onset LBBB and later time of PPM implantation showed a trend toward predicting a low VP% at 6 months.
format Online
Article
Text
id pubmed-7661645
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wiley Periodicals, Inc.
record_format MEDLINE/PubMed
spelling pubmed-76616452020-11-17 Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement Elzeneini, Mohammed Assaf, Yazan Aalaei‐Andabili, Seyed Hossein Mahmoud, Ahmad Hamburger, Robert Goel, Ramil Bavry, Anthony A Clin Cardiol Clinical Investigations BACKGROUND: In the era of an expanding use of transcatheter aortic valve replacement (TAVR), conduction disturbances and the requirement for permanent pacemaker (PPM) implantation remains a clinical concern. HYPOTHESIS: Using a single‐center experience, we sought to identify predictors of ventricular pacing burden after TAVR in patients who required PPM implantation. METHODS: We conducted a retrospective study of 359 consecutive patients with symptomatic severe aortic valve stenosis who underwent TAVR at our institution between September 2013 and July 2019. Thirty patients (8.4%) required a PPM within 30 days after TAVR. Pre and post‐TAVR electrocardiograms, pre‐TAVR echocardiograms and computed tomography (CT), TAVR procedural details and post‐TAVR device interrogation records at 1, 3, and 6 months were reviewed. RESULTS: Mean percentage of ventricular pacing (VP%) at 1, 3, and 6 months was 58%, 59%, and 56% respectively. Using univariate logistic regression analysis, patients who had low VP% < 5% at 6 months were more likely to have a prosthesis/echocardiography‐derived left ventricular outflow tract (LVOT) diameter ratio < 1.3 (OR 7.00, P‐value .048), prosthesis/CT‐derived aortic annulus diameter ratio < 1.02 (OR 7.11, P‐value .047), post‐TAVR new‐onset LBBB (OR 16.80, P‐value .019), time to PPM implantation greater than 2 days post‐TAVR (OR 9.38, P‐value .026) and pre‐TAVR use of a beta blocker (OR 9.40, P‐value .026). CONCLUSIONS: In patients who required a PPM implantation post‐TAVR, a lower TAVR prosthesis/LVOT or aortic annulus diameter ratio, post‐TAVR new‐onset LBBB and later time of PPM implantation showed a trend toward predicting a low VP% at 6 months. Wiley Periodicals, Inc. 2020-09-04 /pmc/articles/PMC7661645/ /pubmed/32886389 http://dx.doi.org/10.1002/clc.23447 Text en © 2020 The Authors. Clinical Cardiology published by Wiley Periodicals LLC.. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Investigations
Elzeneini, Mohammed
Assaf, Yazan
Aalaei‐Andabili, Seyed Hossein
Mahmoud, Ahmad
Hamburger, Robert
Goel, Ramil
Bavry, Anthony A
Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
title Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
title_full Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
title_fullStr Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
title_full_unstemmed Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
title_short Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
title_sort predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
topic Clinical Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7661645/
https://www.ncbi.nlm.nih.gov/pubmed/32886389
http://dx.doi.org/10.1002/clc.23447
work_keys_str_mv AT elzeneinimohammed predictorsofventricularpacingburdenafterpermanentpacemakerimplantationfollowingtranscatheteraorticvalvereplacement
AT assafyazan predictorsofventricularpacingburdenafterpermanentpacemakerimplantationfollowingtranscatheteraorticvalvereplacement
AT aalaeiandabiliseyedhossein predictorsofventricularpacingburdenafterpermanentpacemakerimplantationfollowingtranscatheteraorticvalvereplacement
AT mahmoudahmad predictorsofventricularpacingburdenafterpermanentpacemakerimplantationfollowingtranscatheteraorticvalvereplacement
AT hamburgerrobert predictorsofventricularpacingburdenafterpermanentpacemakerimplantationfollowingtranscatheteraorticvalvereplacement
AT goelramil predictorsofventricularpacingburdenafterpermanentpacemakerimplantationfollowingtranscatheteraorticvalvereplacement
AT bavryanthonya predictorsofventricularpacingburdenafterpermanentpacemakerimplantationfollowingtranscatheteraorticvalvereplacement