Cargando…

In silico Accuracy and Energy Efficiency of Two Steering Paradigms in Directional Deep Brain Stimulation

Background: In Deep Brain Stimulation (DBS), stimulation field steering is used to achieve stimulation spatial specificity, which is critical to obtain clinical benefits and avoid side effects. Multiple Independent Current Control (MICC) and Interleaving/Multi Stim Set (Interleaving/MSS) are two sti...

Descripción completa

Detalles Bibliográficos
Autor principal: Juárez-Paz, León Mauricio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7661934/
https://www.ncbi.nlm.nih.gov/pubmed/33193061
http://dx.doi.org/10.3389/fneur.2020.593798
_version_ 1783609301325053952
author Juárez-Paz, León Mauricio
author_facet Juárez-Paz, León Mauricio
author_sort Juárez-Paz, León Mauricio
collection PubMed
description Background: In Deep Brain Stimulation (DBS), stimulation field steering is used to achieve stimulation spatial specificity, which is critical to obtain clinical benefits and avoid side effects. Multiple Independent Current Control (MICC) and Interleaving/Multi Stim Set (Interleaving/MSS) are two stimulation field steering paradigms in commercially available DBS systems. This work investigates the stimulation field steering accuracy and energy efficiency of these two paradigms in directional DBS. Methods: Volumes of Tissue Activated (VTAs) were generated in silico using pulse widths of 60 μs and five pulse amplitude fractionalizations intended to steer the VTAs radially in 12° steps. For each fractionalization, VTAs were generated with nine pre-defined target radii. Stimulation field steering accuracy was assessed based on the VTAs rotation angle. Energy efficiency was inferred from current draw from battery values, which were calculated based on the pulse amplitudes needed to generate and steer the VTAs, as well as electrode impedance measurements of clinically implanted directional leads. Results: For radial steering, MICC needed a single VTA. In contrast, Interleaving/MSS required the generation of two VTAs, whose union and intersection created an Interleaving/MSS VTA and an Intersection VTA, respectively. MICC VTAs were 6.8 (−3.2–11.8)% larger than Interleaving/MSS VTAs. The Intersection VTAs accounted for 26.2 (16.0–32.8)% of Interleaving/MSS VTAs and were exposed to a higher stimulation frequency. For all VTA radius-fractionalization combinations, steering accuracy was 7.0 (4.5–10.5)° for MICC and 24.0 (9.0–25.3)° for Interleaving/MSS. Pulse amplitudes were 16.1 (9.2–28.6)% lower for MICC than for Interleaving/MSS, leading to a 45.9 (18.8–72.6)% lower current draw from battery for MICC. Conclusions: The results of this work show that in silico, MICC achieves a significantly better stimulation field steering accuracy and has a significantly higher energy efficiency than Interleaving/MSS. Although direct evidence still needs to be generated to translate the results of this work to clinical practice, clinical outcomes may profit from the better stimulation field steering accuracy of MICC and longevity of DBS systems may profit from its higher energy efficiency.
format Online
Article
Text
id pubmed-7661934
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-76619342020-11-13 In silico Accuracy and Energy Efficiency of Two Steering Paradigms in Directional Deep Brain Stimulation Juárez-Paz, León Mauricio Front Neurol Neurology Background: In Deep Brain Stimulation (DBS), stimulation field steering is used to achieve stimulation spatial specificity, which is critical to obtain clinical benefits and avoid side effects. Multiple Independent Current Control (MICC) and Interleaving/Multi Stim Set (Interleaving/MSS) are two stimulation field steering paradigms in commercially available DBS systems. This work investigates the stimulation field steering accuracy and energy efficiency of these two paradigms in directional DBS. Methods: Volumes of Tissue Activated (VTAs) were generated in silico using pulse widths of 60 μs and five pulse amplitude fractionalizations intended to steer the VTAs radially in 12° steps. For each fractionalization, VTAs were generated with nine pre-defined target radii. Stimulation field steering accuracy was assessed based on the VTAs rotation angle. Energy efficiency was inferred from current draw from battery values, which were calculated based on the pulse amplitudes needed to generate and steer the VTAs, as well as electrode impedance measurements of clinically implanted directional leads. Results: For radial steering, MICC needed a single VTA. In contrast, Interleaving/MSS required the generation of two VTAs, whose union and intersection created an Interleaving/MSS VTA and an Intersection VTA, respectively. MICC VTAs were 6.8 (−3.2–11.8)% larger than Interleaving/MSS VTAs. The Intersection VTAs accounted for 26.2 (16.0–32.8)% of Interleaving/MSS VTAs and were exposed to a higher stimulation frequency. For all VTA radius-fractionalization combinations, steering accuracy was 7.0 (4.5–10.5)° for MICC and 24.0 (9.0–25.3)° for Interleaving/MSS. Pulse amplitudes were 16.1 (9.2–28.6)% lower for MICC than for Interleaving/MSS, leading to a 45.9 (18.8–72.6)% lower current draw from battery for MICC. Conclusions: The results of this work show that in silico, MICC achieves a significantly better stimulation field steering accuracy and has a significantly higher energy efficiency than Interleaving/MSS. Although direct evidence still needs to be generated to translate the results of this work to clinical practice, clinical outcomes may profit from the better stimulation field steering accuracy of MICC and longevity of DBS systems may profit from its higher energy efficiency. Frontiers Media S.A. 2020-10-30 /pmc/articles/PMC7661934/ /pubmed/33193061 http://dx.doi.org/10.3389/fneur.2020.593798 Text en Copyright © 2020 Juárez-Paz. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Juárez-Paz, León Mauricio
In silico Accuracy and Energy Efficiency of Two Steering Paradigms in Directional Deep Brain Stimulation
title In silico Accuracy and Energy Efficiency of Two Steering Paradigms in Directional Deep Brain Stimulation
title_full In silico Accuracy and Energy Efficiency of Two Steering Paradigms in Directional Deep Brain Stimulation
title_fullStr In silico Accuracy and Energy Efficiency of Two Steering Paradigms in Directional Deep Brain Stimulation
title_full_unstemmed In silico Accuracy and Energy Efficiency of Two Steering Paradigms in Directional Deep Brain Stimulation
title_short In silico Accuracy and Energy Efficiency of Two Steering Paradigms in Directional Deep Brain Stimulation
title_sort in silico accuracy and energy efficiency of two steering paradigms in directional deep brain stimulation
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7661934/
https://www.ncbi.nlm.nih.gov/pubmed/33193061
http://dx.doi.org/10.3389/fneur.2020.593798
work_keys_str_mv AT juarezpazleonmauricio insilicoaccuracyandenergyefficiencyoftwosteeringparadigmsindirectionaldeepbrainstimulation