Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity

A new scheme for a calibration-free diode laser absorption spectroscopy (DLAS) sensor for measuring the parameters of harsh zones is proposed. The key element of the scheme is a micro-prism retroreflector (MPRR). The MPRR facilitates an increase in the mechanical stability of the sensor and a decrea...

Descripción completa

Detalles Bibliográficos
Autores principales: Liger, Vladimir, Mironenko, Vladimir, Kuritsyn, Yury, Bolshov, Mikhail
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7662676/
https://www.ncbi.nlm.nih.gov/pubmed/33158251
http://dx.doi.org/10.3390/s20216286
_version_ 1783609451853381632
author Liger, Vladimir
Mironenko, Vladimir
Kuritsyn, Yury
Bolshov, Mikhail
author_facet Liger, Vladimir
Mironenko, Vladimir
Kuritsyn, Yury
Bolshov, Mikhail
author_sort Liger, Vladimir
collection PubMed
description A new scheme for a calibration-free diode laser absorption spectroscopy (DLAS) sensor for measuring the parameters of harsh zones is proposed. The key element of the scheme is a micro-prism retroreflector (MPRR). The MPRR facilitates an increase in the mechanical stability of the sensor and a decrease in the background thermal radiation in the hot areas of a tested zone. Reduction in the broadband thermal emission allowed the application of a differential logarithmic conversion (LC) technique for elimination of the residual amplitude modulation and other sources of non-selective attenuation of the probing laser beam. LC allows the use of a 1f-wavelength modulation spectroscopy (WMS) detection scheme. Combination of LC and a 1f-WMS algorithm provided a new modification of calibration-free DLAS, which could be particularly useful for probing harsh zones with pronounced strong turbulence and high levels of acoustic and electrical noise. The influence of the experimental parameters and characteristics of the main electronic components of the recording and processing system on the accuracy of the integral line intensity determination is investigated theoretically and experimentally. The proposed optical scheme of a DLAS sensor and algorithm for the data processing allowed the integral intensity of an absorption line to be obtained. The potential for the scheme was exemplified with a single water vapor absorption line at 7185.6 cm(−1). Simultaneous detection of several absorption lines and data processing using the developed algorithm provides the final goal of a DLAS sensor—determination of temperature and partial pressure of a test molecule in a probed gas volume. The developed scheme allows the spatial multiplexing of the radiation of different diode lasers (DLs), which can be used if various test molecules are to be detected, or absorption lines of a test molecule are detected over different wavelength intervals.
format Online
Article
Text
id pubmed-7662676
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76626762020-11-14 Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity Liger, Vladimir Mironenko, Vladimir Kuritsyn, Yury Bolshov, Mikhail Sensors (Basel) Article A new scheme for a calibration-free diode laser absorption spectroscopy (DLAS) sensor for measuring the parameters of harsh zones is proposed. The key element of the scheme is a micro-prism retroreflector (MPRR). The MPRR facilitates an increase in the mechanical stability of the sensor and a decrease in the background thermal radiation in the hot areas of a tested zone. Reduction in the broadband thermal emission allowed the application of a differential logarithmic conversion (LC) technique for elimination of the residual amplitude modulation and other sources of non-selective attenuation of the probing laser beam. LC allows the use of a 1f-wavelength modulation spectroscopy (WMS) detection scheme. Combination of LC and a 1f-WMS algorithm provided a new modification of calibration-free DLAS, which could be particularly useful for probing harsh zones with pronounced strong turbulence and high levels of acoustic and electrical noise. The influence of the experimental parameters and characteristics of the main electronic components of the recording and processing system on the accuracy of the integral line intensity determination is investigated theoretically and experimentally. The proposed optical scheme of a DLAS sensor and algorithm for the data processing allowed the integral intensity of an absorption line to be obtained. The potential for the scheme was exemplified with a single water vapor absorption line at 7185.6 cm(−1). Simultaneous detection of several absorption lines and data processing using the developed algorithm provides the final goal of a DLAS sensor—determination of temperature and partial pressure of a test molecule in a probed gas volume. The developed scheme allows the spatial multiplexing of the radiation of different diode lasers (DLs), which can be used if various test molecules are to be detected, or absorption lines of a test molecule are detected over different wavelength intervals. MDPI 2020-11-04 /pmc/articles/PMC7662676/ /pubmed/33158251 http://dx.doi.org/10.3390/s20216286 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liger, Vladimir
Mironenko, Vladimir
Kuritsyn, Yury
Bolshov, Mikhail
Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity
title Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity
title_full Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity
title_fullStr Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity
title_full_unstemmed Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity
title_short Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity
title_sort advanced fiber-coupled diode laser sensor for calibration-free 1f-wms determination of an absorption line intensity
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7662676/
https://www.ncbi.nlm.nih.gov/pubmed/33158251
http://dx.doi.org/10.3390/s20216286
work_keys_str_mv AT ligervladimir advancedfibercoupleddiodelasersensorforcalibrationfree1fwmsdeterminationofanabsorptionlineintensity
AT mironenkovladimir advancedfibercoupleddiodelasersensorforcalibrationfree1fwmsdeterminationofanabsorptionlineintensity
AT kuritsynyury advancedfibercoupleddiodelasersensorforcalibrationfree1fwmsdeterminationofanabsorptionlineintensity
AT bolshovmikhail advancedfibercoupleddiodelasersensorforcalibrationfree1fwmsdeterminationofanabsorptionlineintensity