Cargando…
Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial †
Background: Alternative cardiopulmonary resuscitation (CPR) algorithms, introduced to improve outcomes after cardiac arrest, have so far not been compared in randomized trials with established CPR guidelines. Methods: 286 physician teams were confronted with simulated cardiac arrests and randomly al...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7662801/ https://www.ncbi.nlm.nih.gov/pubmed/33138109 http://dx.doi.org/10.3390/ijerph17217946 |
_version_ | 1783609481015328768 |
---|---|
author | Rifai, Sami Sellmann, Timur Wetzchewald, Dietmar Schwager, Heidrun Tschan, Franziska Russo, Sebastian G. Marsch, Stephan |
author_facet | Rifai, Sami Sellmann, Timur Wetzchewald, Dietmar Schwager, Heidrun Tschan, Franziska Russo, Sebastian G. Marsch, Stephan |
author_sort | Rifai, Sami |
collection | PubMed |
description | Background: Alternative cardiopulmonary resuscitation (CPR) algorithms, introduced to improve outcomes after cardiac arrest, have so far not been compared in randomized trials with established CPR guidelines. Methods: 286 physician teams were confronted with simulated cardiac arrests and randomly allocated to one of three versions of a CPR algorithm: (1) current International Liaison Committee on Resuscitation (ILCOR) guidelines (“ILCOR”), (2) the cardiocerebral resuscitation (“CCR”) protocol (3 cycles of 200 uninterrupted chest compressions with no ventilation), or (3) a local interpretation of the current guidelines (“Arnsberg“, immediate insertion of a supraglottic airway and cycles of 200 uninterrupted chest compressions). The primary endpoint was percentage of hands-on time. Results: Median percentage of hands-on time was 88 (interquartile range (IQR) 6) in “ILCOR” teams, 90 (IQR 5) in “CCR” teams (p = 0.001 vs. “ILCOR”), and 89 (IQR 4) in “Arnsberg” teams (p = 0.032 vs. “ILCOR”; p = 0.10 vs. “CCR”). “ILCOR” teams delivered fewer chest compressions and deviated more from allocated targets than “CCR” and “Arnsberg” teams. “CCR” teams demonstrated the least within-team and between-team variance. Conclusions: Compared to current ILCOR guidelines, two alternative CPR algorithms advocating cycles of uninterrupted chest compressions resulted in very similar hands-on times, fewer deviations from targets, and less within-team and between-team variance in execution. |
format | Online Article Text |
id | pubmed-7662801 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76628012020-11-14 Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial † Rifai, Sami Sellmann, Timur Wetzchewald, Dietmar Schwager, Heidrun Tschan, Franziska Russo, Sebastian G. Marsch, Stephan Int J Environ Res Public Health Article Background: Alternative cardiopulmonary resuscitation (CPR) algorithms, introduced to improve outcomes after cardiac arrest, have so far not been compared in randomized trials with established CPR guidelines. Methods: 286 physician teams were confronted with simulated cardiac arrests and randomly allocated to one of three versions of a CPR algorithm: (1) current International Liaison Committee on Resuscitation (ILCOR) guidelines (“ILCOR”), (2) the cardiocerebral resuscitation (“CCR”) protocol (3 cycles of 200 uninterrupted chest compressions with no ventilation), or (3) a local interpretation of the current guidelines (“Arnsberg“, immediate insertion of a supraglottic airway and cycles of 200 uninterrupted chest compressions). The primary endpoint was percentage of hands-on time. Results: Median percentage of hands-on time was 88 (interquartile range (IQR) 6) in “ILCOR” teams, 90 (IQR 5) in “CCR” teams (p = 0.001 vs. “ILCOR”), and 89 (IQR 4) in “Arnsberg” teams (p = 0.032 vs. “ILCOR”; p = 0.10 vs. “CCR”). “ILCOR” teams delivered fewer chest compressions and deviated more from allocated targets than “CCR” and “Arnsberg” teams. “CCR” teams demonstrated the least within-team and between-team variance. Conclusions: Compared to current ILCOR guidelines, two alternative CPR algorithms advocating cycles of uninterrupted chest compressions resulted in very similar hands-on times, fewer deviations from targets, and less within-team and between-team variance in execution. MDPI 2020-10-29 2020-11 /pmc/articles/PMC7662801/ /pubmed/33138109 http://dx.doi.org/10.3390/ijerph17217946 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rifai, Sami Sellmann, Timur Wetzchewald, Dietmar Schwager, Heidrun Tschan, Franziska Russo, Sebastian G. Marsch, Stephan Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial † |
title | Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial † |
title_full | Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial † |
title_fullStr | Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial † |
title_full_unstemmed | Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial † |
title_short | Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial † |
title_sort | hands-on times, adherence to recommendations and variance in execution among three different cpr algorithms: a prospective randomized single-blind simulator-based trial † |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7662801/ https://www.ncbi.nlm.nih.gov/pubmed/33138109 http://dx.doi.org/10.3390/ijerph17217946 |
work_keys_str_mv | AT rifaisami handsontimesadherencetorecommendationsandvarianceinexecutionamongthreedifferentcpralgorithmsaprospectiverandomizedsingleblindsimulatorbasedtrial AT sellmanntimur handsontimesadherencetorecommendationsandvarianceinexecutionamongthreedifferentcpralgorithmsaprospectiverandomizedsingleblindsimulatorbasedtrial AT wetzchewalddietmar handsontimesadherencetorecommendationsandvarianceinexecutionamongthreedifferentcpralgorithmsaprospectiverandomizedsingleblindsimulatorbasedtrial AT schwagerheidrun handsontimesadherencetorecommendationsandvarianceinexecutionamongthreedifferentcpralgorithmsaprospectiverandomizedsingleblindsimulatorbasedtrial AT tschanfranziska handsontimesadherencetorecommendationsandvarianceinexecutionamongthreedifferentcpralgorithmsaprospectiverandomizedsingleblindsimulatorbasedtrial AT russosebastiang handsontimesadherencetorecommendationsandvarianceinexecutionamongthreedifferentcpralgorithmsaprospectiverandomizedsingleblindsimulatorbasedtrial AT marschstephan handsontimesadherencetorecommendationsandvarianceinexecutionamongthreedifferentcpralgorithmsaprospectiverandomizedsingleblindsimulatorbasedtrial |