A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty

There is increasing evidence that pelvic mobility is a critical factor to consider in implant alignment during total hip arthroplasty (THA). Here, we test the feasibility of using an inertial sensor fitted across the sacrum to measure change in pelvic tilt, and hence screen for patients with high pe...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Xueyang, Qureshi, Arham, Vepa, Abhinav, Rahman, Usama, Palit, Arnab, Williams, Mark A., King, Richard, Elliott, Mark T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663251/
https://www.ncbi.nlm.nih.gov/pubmed/33143034
http://dx.doi.org/10.3390/s20216182
_version_ 1783609584313696256
author Wang, Xueyang
Qureshi, Arham
Vepa, Abhinav
Rahman, Usama
Palit, Arnab
Williams, Mark A.
King, Richard
Elliott, Mark T.
author_facet Wang, Xueyang
Qureshi, Arham
Vepa, Abhinav
Rahman, Usama
Palit, Arnab
Williams, Mark A.
King, Richard
Elliott, Mark T.
author_sort Wang, Xueyang
collection PubMed
description There is increasing evidence that pelvic mobility is a critical factor to consider in implant alignment during total hip arthroplasty (THA). Here, we test the feasibility of using an inertial sensor fitted across the sacrum to measure change in pelvic tilt, and hence screen for patients with high pelvic mobility. Patients (n = 32, mean age: 57.4 years) due to receive THA surgery participated in the study. Measures of pelvic tilt were captured simultaneously using the device and radiograph in three functional positions: Standing, flexed-seated, and step-up. We found a strong correlation between the device and radiograph measures for the change in pelvic tilt measure from standing to flexed-seated position (R(2) = 0.911); 75% of absolute errors were under 5 degrees. We demonstrated that the device can be used as a screening tool to rapidly identify patients who would benefit from more detailed surgical planning of implant positioning to reduce future risks of impingement and dislocation.
format Online
Article
Text
id pubmed-7663251
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76632512020-11-14 A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty Wang, Xueyang Qureshi, Arham Vepa, Abhinav Rahman, Usama Palit, Arnab Williams, Mark A. King, Richard Elliott, Mark T. Sensors (Basel) Article There is increasing evidence that pelvic mobility is a critical factor to consider in implant alignment during total hip arthroplasty (THA). Here, we test the feasibility of using an inertial sensor fitted across the sacrum to measure change in pelvic tilt, and hence screen for patients with high pelvic mobility. Patients (n = 32, mean age: 57.4 years) due to receive THA surgery participated in the study. Measures of pelvic tilt were captured simultaneously using the device and radiograph in three functional positions: Standing, flexed-seated, and step-up. We found a strong correlation between the device and radiograph measures for the change in pelvic tilt measure from standing to flexed-seated position (R(2) = 0.911); 75% of absolute errors were under 5 degrees. We demonstrated that the device can be used as a screening tool to rapidly identify patients who would benefit from more detailed surgical planning of implant positioning to reduce future risks of impingement and dislocation. MDPI 2020-10-30 /pmc/articles/PMC7663251/ /pubmed/33143034 http://dx.doi.org/10.3390/s20216182 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Xueyang
Qureshi, Arham
Vepa, Abhinav
Rahman, Usama
Palit, Arnab
Williams, Mark A.
King, Richard
Elliott, Mark T.
A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty
title A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty
title_full A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty
title_fullStr A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty
title_full_unstemmed A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty
title_short A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty
title_sort sensor-based screening tool for identifying high pelvic mobility in patients due to undergo total hip arthroplasty
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663251/
https://www.ncbi.nlm.nih.gov/pubmed/33143034
http://dx.doi.org/10.3390/s20216182
work_keys_str_mv AT wangxueyang asensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT qureshiarham asensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT vepaabhinav asensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT rahmanusama asensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT palitarnab asensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT williamsmarka asensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT kingrichard asensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT elliottmarkt asensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT wangxueyang sensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT qureshiarham sensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT vepaabhinav sensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT rahmanusama sensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT palitarnab sensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT williamsmarka sensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT kingrichard sensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty
AT elliottmarkt sensorbasedscreeningtoolforidentifyinghighpelvicmobilityinpatientsduetoundergototalhiparthroplasty