Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring

Long-term electrocardiography (ECG) monitoring is very essential for the early detection and treatment of cardiovascular disorders. However, commercially used silver/silver chloride (Ag/AgCl) electrodes have drawbacks, and these become more obvious during long-term signal monitoring, making them inc...

Descripción completa

Detalles Bibliográficos
Autores principales: Nigusse, Abreha Bayrau, Malengier, Benny, Mengistie, Desalegn Alemu, Tseghai, Granch Berhe, Van Langenhove, Lieva
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663435/
https://www.ncbi.nlm.nih.gov/pubmed/33142899
http://dx.doi.org/10.3390/s20216233
_version_ 1783609626412974080
author Nigusse, Abreha Bayrau
Malengier, Benny
Mengistie, Desalegn Alemu
Tseghai, Granch Berhe
Van Langenhove, Lieva
author_facet Nigusse, Abreha Bayrau
Malengier, Benny
Mengistie, Desalegn Alemu
Tseghai, Granch Berhe
Van Langenhove, Lieva
author_sort Nigusse, Abreha Bayrau
collection PubMed
description Long-term electrocardiography (ECG) monitoring is very essential for the early detection and treatment of cardiovascular disorders. However, commercially used silver/silver chloride (Ag/AgCl) electrodes have drawbacks, and these become more obvious during long-term signal monitoring, making them inconvenient for this use. In this study, we developed silver printed textile electrodes from knitted cotton and polyester fabric for ECG monitoring. The surface resistance of printed electrodes was 1.64 Ω/sq for cotton and 1.78 Ω/sq for polyester electrodes. The ECG detection performance of the electrodes was studied by placing three electrodes around the wrist where the electrodes were embedded on an elastic strap with Velcro. The ECG signals collected using textile electrodes had a comparable waveform to those acquired using standard Ag/AgCl electrodes with a signal to noise ratio (SNR) of 33.10, 30.17, and 33.52 dB for signals collected from cotton, polyester, and Ag/AgCl electrodes, respectively. The signal quality increased as the tightness of the elastic strap increased. Signals acquired at 15 mmHg pressure level with the textile electrodes provided a similar quality to those acquired using standard electrodes. Interestingly, the textile electrodes gave acceptable signal quality even after ten washing cycles.
format Online
Article
Text
id pubmed-7663435
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76634352020-11-14 Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring Nigusse, Abreha Bayrau Malengier, Benny Mengistie, Desalegn Alemu Tseghai, Granch Berhe Van Langenhove, Lieva Sensors (Basel) Article Long-term electrocardiography (ECG) monitoring is very essential for the early detection and treatment of cardiovascular disorders. However, commercially used silver/silver chloride (Ag/AgCl) electrodes have drawbacks, and these become more obvious during long-term signal monitoring, making them inconvenient for this use. In this study, we developed silver printed textile electrodes from knitted cotton and polyester fabric for ECG monitoring. The surface resistance of printed electrodes was 1.64 Ω/sq for cotton and 1.78 Ω/sq for polyester electrodes. The ECG detection performance of the electrodes was studied by placing three electrodes around the wrist where the electrodes were embedded on an elastic strap with Velcro. The ECG signals collected using textile electrodes had a comparable waveform to those acquired using standard Ag/AgCl electrodes with a signal to noise ratio (SNR) of 33.10, 30.17, and 33.52 dB for signals collected from cotton, polyester, and Ag/AgCl electrodes, respectively. The signal quality increased as the tightness of the elastic strap increased. Signals acquired at 15 mmHg pressure level with the textile electrodes provided a similar quality to those acquired using standard electrodes. Interestingly, the textile electrodes gave acceptable signal quality even after ten washing cycles. MDPI 2020-10-31 /pmc/articles/PMC7663435/ /pubmed/33142899 http://dx.doi.org/10.3390/s20216233 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nigusse, Abreha Bayrau
Malengier, Benny
Mengistie, Desalegn Alemu
Tseghai, Granch Berhe
Van Langenhove, Lieva
Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring
title Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring
title_full Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring
title_fullStr Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring
title_full_unstemmed Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring
title_short Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring
title_sort development of washable silver printed textile electrodes for long-term ecg monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663435/
https://www.ncbi.nlm.nih.gov/pubmed/33142899
http://dx.doi.org/10.3390/s20216233
work_keys_str_mv AT nigusseabrehabayrau developmentofwashablesilverprintedtextileelectrodesforlongtermecgmonitoring
AT malengierbenny developmentofwashablesilverprintedtextileelectrodesforlongtermecgmonitoring
AT mengistiedesalegnalemu developmentofwashablesilverprintedtextileelectrodesforlongtermecgmonitoring
AT tseghaigranchberhe developmentofwashablesilverprintedtextileelectrodesforlongtermecgmonitoring
AT vanlangenhovelieva developmentofwashablesilverprintedtextileelectrodesforlongtermecgmonitoring