A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile
Background: Orthodontic mini-implant failure is a debatable subject in clinical practice. However, the most important parameter to evaluate the success rate of mini-implant is the primary stability, which is mainly influenced by cortical bone thickness (CBT) and insertion angle. Materials and method...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663474/ https://www.ncbi.nlm.nih.gov/pubmed/33120951 http://dx.doi.org/10.3390/ma13214789 |
_version_ | 1783609635072114688 |
---|---|
author | Popa, Adelina Dehelean, Cristina Calniceanu, Horia Watz, Claudia Brad, Silviu Sinescu, Cosmin Marcu, Olivia A. Popa, Casiana Simina Avram, Stefana Nicolov, Mirela Szuhanek, Camelia A. |
author_facet | Popa, Adelina Dehelean, Cristina Calniceanu, Horia Watz, Claudia Brad, Silviu Sinescu, Cosmin Marcu, Olivia A. Popa, Casiana Simina Avram, Stefana Nicolov, Mirela Szuhanek, Camelia A. |
author_sort | Popa, Adelina |
collection | PubMed |
description | Background: Orthodontic mini-implant failure is a debatable subject in clinical practice. However, the most important parameter to evaluate the success rate of mini-implant is the primary stability, which is mainly influenced by cortical bone thickness (CBT) and insertion angle. Materials and methods: Three-dimensional finite element models of the maxilla were created and a custom-made, self-drilling, tapered mini-implant was designed. For the pull-out test, 12 simulations were performed, sequentially increasing the thickness of the cortical bone (1, 1.5 and 2 mm) and the insertion angle (30°, 60°, 90°, 120°). For the force analysis, 24 simulations were performed using an experimental orthodontic traction force of 2 N both in the horizontal and vertical axis. Results: Insertion angle and CBT have significant impact on force reaction values (p < 0.05). Cortical bone stress had the lowest value when the mini-implant had a 30° insertion angle and the highest value when the implant had a 120° insertion angle, while the CBT was 1 mm. Cortical bone stress had the lowest value with an insertion angle of 90° and the highest value when the implant was inserted at an angle of 30°, while the CBT was 2 mm independent of the force direction. Regarding the biosafety profile of the mini-implant alloy, the present results reveal that the custom-made mini-implant presents good biocompatibility. Conclusions: When the CBT is reduced, we recommend inclined insertion while, when the CBT is appropriate, perpendicular insertion is advised. |
format | Online Article Text |
id | pubmed-7663474 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76634742020-11-14 A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile Popa, Adelina Dehelean, Cristina Calniceanu, Horia Watz, Claudia Brad, Silviu Sinescu, Cosmin Marcu, Olivia A. Popa, Casiana Simina Avram, Stefana Nicolov, Mirela Szuhanek, Camelia A. Materials (Basel) Article Background: Orthodontic mini-implant failure is a debatable subject in clinical practice. However, the most important parameter to evaluate the success rate of mini-implant is the primary stability, which is mainly influenced by cortical bone thickness (CBT) and insertion angle. Materials and methods: Three-dimensional finite element models of the maxilla were created and a custom-made, self-drilling, tapered mini-implant was designed. For the pull-out test, 12 simulations were performed, sequentially increasing the thickness of the cortical bone (1, 1.5 and 2 mm) and the insertion angle (30°, 60°, 90°, 120°). For the force analysis, 24 simulations were performed using an experimental orthodontic traction force of 2 N both in the horizontal and vertical axis. Results: Insertion angle and CBT have significant impact on force reaction values (p < 0.05). Cortical bone stress had the lowest value when the mini-implant had a 30° insertion angle and the highest value when the implant had a 120° insertion angle, while the CBT was 1 mm. Cortical bone stress had the lowest value with an insertion angle of 90° and the highest value when the implant was inserted at an angle of 30°, while the CBT was 2 mm independent of the force direction. Regarding the biosafety profile of the mini-implant alloy, the present results reveal that the custom-made mini-implant presents good biocompatibility. Conclusions: When the CBT is reduced, we recommend inclined insertion while, when the CBT is appropriate, perpendicular insertion is advised. MDPI 2020-10-27 /pmc/articles/PMC7663474/ /pubmed/33120951 http://dx.doi.org/10.3390/ma13214789 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Popa, Adelina Dehelean, Cristina Calniceanu, Horia Watz, Claudia Brad, Silviu Sinescu, Cosmin Marcu, Olivia A. Popa, Casiana Simina Avram, Stefana Nicolov, Mirela Szuhanek, Camelia A. A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile |
title | A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile |
title_full | A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile |
title_fullStr | A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile |
title_full_unstemmed | A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile |
title_short | A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile |
title_sort | custom-made orthodontic mini-implant—effect of insertion angle and cortical bone thickness on stress distribution with a complex in vitro and in vivo biosafety profile |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663474/ https://www.ncbi.nlm.nih.gov/pubmed/33120951 http://dx.doi.org/10.3390/ma13214789 |
work_keys_str_mv | AT popaadelina acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT deheleancristina acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT calniceanuhoria acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT watzclaudia acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT bradsilviu acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT sinescucosmin acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT marcuoliviaa acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT popacasianasimina acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT avramstefana acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT nicolovmirela acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT szuhanekcameliaa acustommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT popaadelina custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT deheleancristina custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT calniceanuhoria custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT watzclaudia custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT bradsilviu custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT sinescucosmin custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT marcuoliviaa custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT popacasianasimina custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT avramstefana custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT nicolovmirela custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile AT szuhanekcameliaa custommadeorthodonticminiimplanteffectofinsertionangleandcorticalbonethicknessonstressdistributionwithacomplexinvitroandinvivobiosafetyprofile |