Cargando…
New Procedure for the Kinematic and Power Analysis of Cyclists in Indoor Training
In this research, the performance and movements of amateur and professional cyclists were analyzed. For this, reflective markers have been used on different parts of the body of the participants in conjunction with sports cameras and a mobile power meter. The trajectories of the markers have been ob...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663547/ https://www.ncbi.nlm.nih.gov/pubmed/33126665 http://dx.doi.org/10.3390/s20216135 |
_version_ | 1783609652210040832 |
---|---|
author | Calvo, José Antonio Álvarez-Caldas, Carolina San Román, José Luis Gutiérrez-Moizant, Ramón |
author_facet | Calvo, José Antonio Álvarez-Caldas, Carolina San Román, José Luis Gutiérrez-Moizant, Ramón |
author_sort | Calvo, José Antonio |
collection | PubMed |
description | In this research, the performance and movements of amateur and professional cyclists were analyzed. For this, reflective markers have been used on different parts of the body of the participants in conjunction with sports cameras and a mobile power meter. The trajectories of the markers have been obtained with the software Kinovea and subsequently analyzed using error ellipses. It is demonstrated that the error ellipses help determine movement patterns in the knees, back, and hip. The covariance of the error ellipses can be indicative of the alignment and symmetry of the frontal movement of the knees. In addition, it allows verifying the alignment of the spine and the symmetry of the hip. Finally, it is shown that it is necessary to consider the uncertainty of the power devices since it considerably affects the evaluation of the cyclists’ performance. Devices with high uncertainty will demand a greater effort from the cyclist to meet the power required in the endurance test developed. The statistical magnitudes considered help to analyze power and evaluate the cyclists’ performance. |
format | Online Article Text |
id | pubmed-7663547 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76635472020-11-14 New Procedure for the Kinematic and Power Analysis of Cyclists in Indoor Training Calvo, José Antonio Álvarez-Caldas, Carolina San Román, José Luis Gutiérrez-Moizant, Ramón Sensors (Basel) Article In this research, the performance and movements of amateur and professional cyclists were analyzed. For this, reflective markers have been used on different parts of the body of the participants in conjunction with sports cameras and a mobile power meter. The trajectories of the markers have been obtained with the software Kinovea and subsequently analyzed using error ellipses. It is demonstrated that the error ellipses help determine movement patterns in the knees, back, and hip. The covariance of the error ellipses can be indicative of the alignment and symmetry of the frontal movement of the knees. In addition, it allows verifying the alignment of the spine and the symmetry of the hip. Finally, it is shown that it is necessary to consider the uncertainty of the power devices since it considerably affects the evaluation of the cyclists’ performance. Devices with high uncertainty will demand a greater effort from the cyclist to meet the power required in the endurance test developed. The statistical magnitudes considered help to analyze power and evaluate the cyclists’ performance. MDPI 2020-10-28 /pmc/articles/PMC7663547/ /pubmed/33126665 http://dx.doi.org/10.3390/s20216135 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Calvo, José Antonio Álvarez-Caldas, Carolina San Román, José Luis Gutiérrez-Moizant, Ramón New Procedure for the Kinematic and Power Analysis of Cyclists in Indoor Training |
title | New Procedure for the Kinematic and Power Analysis of Cyclists in Indoor Training |
title_full | New Procedure for the Kinematic and Power Analysis of Cyclists in Indoor Training |
title_fullStr | New Procedure for the Kinematic and Power Analysis of Cyclists in Indoor Training |
title_full_unstemmed | New Procedure for the Kinematic and Power Analysis of Cyclists in Indoor Training |
title_short | New Procedure for the Kinematic and Power Analysis of Cyclists in Indoor Training |
title_sort | new procedure for the kinematic and power analysis of cyclists in indoor training |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663547/ https://www.ncbi.nlm.nih.gov/pubmed/33126665 http://dx.doi.org/10.3390/s20216135 |
work_keys_str_mv | AT calvojoseantonio newprocedureforthekinematicandpoweranalysisofcyclistsinindoortraining AT alvarezcaldascarolina newprocedureforthekinematicandpoweranalysisofcyclistsinindoortraining AT sanromanjoseluis newprocedureforthekinematicandpoweranalysisofcyclistsinindoortraining AT gutierrezmoizantramon newprocedureforthekinematicandpoweranalysisofcyclistsinindoortraining |