Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
The scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear loa...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663735/ https://www.ncbi.nlm.nih.gov/pubmed/33153117 http://dx.doi.org/10.3390/ma13214938 |
_version_ | 1783609696493502464 |
---|---|
author | Grabski, Maciej Ambroziak, Andrzej |
author_facet | Grabski, Maciej Ambroziak, Andrzej |
author_sort | Grabski, Maciej |
collection | PubMed |
description | The scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear load capacity. The dimensions of the shear head should provide the punching shear resistance of the connection inside and outside the enhanced region. The process of selecting the size of the shear head is iterative. The parametric analysis of the ACI 318 code and EC2 standard has the objective of indicating which control perimeter (inside or outside the shear head) has a decisive impact on the punching shear capacity of the connection. Based on the analysis, the authors propose methods for selecting the dimensions of the shear head with practical application examples. The paper is intended to provide scientists, civil engineers, and designers with guidelines to design the process of the slab–column connections with the shear caps. |
format | Online Article Text |
id | pubmed-7663735 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76637352020-11-14 Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard Grabski, Maciej Ambroziak, Andrzej Materials (Basel) Article The scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear load capacity. The dimensions of the shear head should provide the punching shear resistance of the connection inside and outside the enhanced region. The process of selecting the size of the shear head is iterative. The parametric analysis of the ACI 318 code and EC2 standard has the objective of indicating which control perimeter (inside or outside the shear head) has a decisive impact on the punching shear capacity of the connection. Based on the analysis, the authors propose methods for selecting the dimensions of the shear head with practical application examples. The paper is intended to provide scientists, civil engineers, and designers with guidelines to design the process of the slab–column connections with the shear caps. MDPI 2020-11-03 /pmc/articles/PMC7663735/ /pubmed/33153117 http://dx.doi.org/10.3390/ma13214938 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Grabski, Maciej Ambroziak, Andrzej Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title | Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_full | Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_fullStr | Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_full_unstemmed | Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_short | Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_sort | shear cap size selection method based on parametric analysis of aci-318 code and eurocode 2 standard |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663735/ https://www.ncbi.nlm.nih.gov/pubmed/33153117 http://dx.doi.org/10.3390/ma13214938 |
work_keys_str_mv | AT grabskimaciej shearcapsizeselectionmethodbasedonparametricanalysisofaci318codeandeurocode2standard AT ambroziakandrzej shearcapsizeselectionmethodbasedonparametricanalysisofaci318codeandeurocode2standard |