Cargando…

Performance of Xpert® MTB/RIF in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy

BACKGROUND: Etiological diagnosis of tuberculous pleuritis is challenging, owing to a paucity of Mycobacterium tuberculosis (MTB) in the affected region. Moreover, currently available methods, such as the detection of acid-fast bacilli and microbiological culture, are not always conducive to timely...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Chengjun, Liu, Chang, Sun, Bingqi, Zhang, Wei, Wang, Yang, Sun, Jiao, Ma, Fang, Chen, Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663888/
https://www.ncbi.nlm.nih.gov/pubmed/33183269
http://dx.doi.org/10.1186/s12879-020-05578-3
_version_ 1783609730679177216
author Li, Chengjun
Liu, Chang
Sun, Bingqi
Zhang, Wei
Wang, Yang
Sun, Jiao
Ma, Fang
Chen, Yu
author_facet Li, Chengjun
Liu, Chang
Sun, Bingqi
Zhang, Wei
Wang, Yang
Sun, Jiao
Ma, Fang
Chen, Yu
author_sort Li, Chengjun
collection PubMed
description BACKGROUND: Etiological diagnosis of tuberculous pleuritis is challenging, owing to a paucity of Mycobacterium tuberculosis (MTB) in the affected region. Moreover, currently available methods, such as the detection of acid-fast bacilli and microbiological culture, are not always conducive to timely diagnosis and treatment. In this study, we evaluated the performance of Xpert® MTB/RIF assay (hereinafter referred to as “Xpert”) in detecting MTB in difficult-to-diagnose patients using suspensions of pleural biopsy tissue specimens obtained under direct thoracoscopic guidance. METHODS: One hundred and sixty patients with an unexplained pleural effusion were included from the Shenyang Tenth People’s Hospital and Shenyang Chest Hospital, China, between 2017 and 2018. The included patients underwent thoracoscopy under local anesthesia, with an intercostal incision of approximately 1.0 cm for biopsy. The biopsy specimens were used for pathological and etiological examinations. The Xpert test was evaluated for its sensitivity and specificity, as well as positive and negative predictive values (PPV and NPV, respectively), against data obtained using standards: the BACTEC™ MGIT™ 960 liquid culture system and a composite reference standard (CRS). RESULTS: The sensitivity and specificity of Xpert were 68.8 and 64.6%, respectively, against the MGIT 960 culture data. The PPV and NPV of Xpert were 56.4 and 75.6%, respectively. The sensitivity of Xpert was 69.0% against the CRS data, which was significantly higher than that of MGIT 960 culture (56.6%). The PPV and NPV of Xpert against the CRS data were 100.0 and 57.3%, respectively. CONCLUSIONS: Xpert is a good rule-in test but has limited value as a rule-out test for the diagnosis of tuberculosis pleuritis.
format Online
Article
Text
id pubmed-7663888
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-76638882020-11-13 Performance of Xpert® MTB/RIF in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy Li, Chengjun Liu, Chang Sun, Bingqi Zhang, Wei Wang, Yang Sun, Jiao Ma, Fang Chen, Yu BMC Infect Dis Research Article BACKGROUND: Etiological diagnosis of tuberculous pleuritis is challenging, owing to a paucity of Mycobacterium tuberculosis (MTB) in the affected region. Moreover, currently available methods, such as the detection of acid-fast bacilli and microbiological culture, are not always conducive to timely diagnosis and treatment. In this study, we evaluated the performance of Xpert® MTB/RIF assay (hereinafter referred to as “Xpert”) in detecting MTB in difficult-to-diagnose patients using suspensions of pleural biopsy tissue specimens obtained under direct thoracoscopic guidance. METHODS: One hundred and sixty patients with an unexplained pleural effusion were included from the Shenyang Tenth People’s Hospital and Shenyang Chest Hospital, China, between 2017 and 2018. The included patients underwent thoracoscopy under local anesthesia, with an intercostal incision of approximately 1.0 cm for biopsy. The biopsy specimens were used for pathological and etiological examinations. The Xpert test was evaluated for its sensitivity and specificity, as well as positive and negative predictive values (PPV and NPV, respectively), against data obtained using standards: the BACTEC™ MGIT™ 960 liquid culture system and a composite reference standard (CRS). RESULTS: The sensitivity and specificity of Xpert were 68.8 and 64.6%, respectively, against the MGIT 960 culture data. The PPV and NPV of Xpert were 56.4 and 75.6%, respectively. The sensitivity of Xpert was 69.0% against the CRS data, which was significantly higher than that of MGIT 960 culture (56.6%). The PPV and NPV of Xpert against the CRS data were 100.0 and 57.3%, respectively. CONCLUSIONS: Xpert is a good rule-in test but has limited value as a rule-out test for the diagnosis of tuberculosis pleuritis. BioMed Central 2020-11-12 /pmc/articles/PMC7663888/ /pubmed/33183269 http://dx.doi.org/10.1186/s12879-020-05578-3 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Li, Chengjun
Liu, Chang
Sun, Bingqi
Zhang, Wei
Wang, Yang
Sun, Jiao
Ma, Fang
Chen, Yu
Performance of Xpert® MTB/RIF in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy
title Performance of Xpert® MTB/RIF in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy
title_full Performance of Xpert® MTB/RIF in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy
title_fullStr Performance of Xpert® MTB/RIF in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy
title_full_unstemmed Performance of Xpert® MTB/RIF in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy
title_short Performance of Xpert® MTB/RIF in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy
title_sort performance of xpert® mtb/rif in diagnosing tuberculous pleuritis using thoracoscopic pleural biopsy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7663888/
https://www.ncbi.nlm.nih.gov/pubmed/33183269
http://dx.doi.org/10.1186/s12879-020-05578-3
work_keys_str_mv AT lichengjun performanceofxpertmtbrifindiagnosingtuberculouspleuritisusingthoracoscopicpleuralbiopsy
AT liuchang performanceofxpertmtbrifindiagnosingtuberculouspleuritisusingthoracoscopicpleuralbiopsy
AT sunbingqi performanceofxpertmtbrifindiagnosingtuberculouspleuritisusingthoracoscopicpleuralbiopsy
AT zhangwei performanceofxpertmtbrifindiagnosingtuberculouspleuritisusingthoracoscopicpleuralbiopsy
AT wangyang performanceofxpertmtbrifindiagnosingtuberculouspleuritisusingthoracoscopicpleuralbiopsy
AT sunjiao performanceofxpertmtbrifindiagnosingtuberculouspleuritisusingthoracoscopicpleuralbiopsy
AT mafang performanceofxpertmtbrifindiagnosingtuberculouspleuritisusingthoracoscopicpleuralbiopsy
AT chenyu performanceofxpertmtbrifindiagnosingtuberculouspleuritisusingthoracoscopicpleuralbiopsy