The technique of 3D reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (ICG) clearance test to assess the liver reserve function

BACKGROUND: The indocyanine green (ICG) clearance test is the main method of evaluating the liver reserve function before hepatectomy. However, some patients may be allergic to ICG or the equipment of ICG clearance test was lack, leading to be difficult to evaluate liver reserve function. We aim to...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Jinli, Xie, Wei, Huang, Yang, Zhu, Yunfeng, Jiang, Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7664104/
https://www.ncbi.nlm.nih.gov/pubmed/33183305
http://dx.doi.org/10.1186/s12893-020-00952-z
_version_ 1783609777761288192
author Zheng, Jinli
Xie, Wei
Huang, Yang
Zhu, Yunfeng
Jiang, Li
author_facet Zheng, Jinli
Xie, Wei
Huang, Yang
Zhu, Yunfeng
Jiang, Li
author_sort Zheng, Jinli
collection PubMed
description BACKGROUND: The indocyanine green (ICG) clearance test is the main method of evaluating the liver reserve function before hepatectomy. However, some patients may be allergic to ICG or the equipment of ICG clearance test was lack, leading to be difficult to evaluate liver reserve function. We aim to find an alternative tool to assist the clinicians to evaluate the liver reserve function for those who were allergic to the ICG or lack of equipment before hepatectomy. METHODS: We retrospected 300 patients to investigate the risk factors affecting the liver reserve function and to build an equivalent formula to predict ICG 15 min retention rate (ICG-R15) value. RESULTS: We found that the independent risk factors affecting ICG clearance test were total bilirubin, albumin, and spleen-to-non-neoplastic liver volume ratio (SNLR). The equivalent formula of the serological index combining with SNLR was: ICG-R15 = 0.36 × TB (umol/L) − 0.78 × ALB(g/L) + 7.783 × SNLR + 0.794 × PT (s) − 0.016 × PLT(/10(9)) − 0.039 × ALT (IU/L) + 0.043 × AST (IU/L) + 23.846. The equivalent formula of serum index was: ICG-R15(2) = 24.665 + 0.382 × TB (umol/L) − 0.799 × ALB(g/L) − 0.025 × PLT(/10(9)) + 0.048 × AST(IU/L) − 0.045 × ALT(IU/L). And the area under the ROC curve (AUC) of predicting ICG-R15 ≥ 10% was 0.861 and 0.857, respectively. CONCLUSION: We found that SNLR was an independent risk factor affecting liver reserve function. Combining with SNLR to evaluate the liver reserve function was better than just basing on serology.
format Online
Article
Text
id pubmed-7664104
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-76641042020-11-13 The technique of 3D reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (ICG) clearance test to assess the liver reserve function Zheng, Jinli Xie, Wei Huang, Yang Zhu, Yunfeng Jiang, Li BMC Surg Research Article BACKGROUND: The indocyanine green (ICG) clearance test is the main method of evaluating the liver reserve function before hepatectomy. However, some patients may be allergic to ICG or the equipment of ICG clearance test was lack, leading to be difficult to evaluate liver reserve function. We aim to find an alternative tool to assist the clinicians to evaluate the liver reserve function for those who were allergic to the ICG or lack of equipment before hepatectomy. METHODS: We retrospected 300 patients to investigate the risk factors affecting the liver reserve function and to build an equivalent formula to predict ICG 15 min retention rate (ICG-R15) value. RESULTS: We found that the independent risk factors affecting ICG clearance test were total bilirubin, albumin, and spleen-to-non-neoplastic liver volume ratio (SNLR). The equivalent formula of the serological index combining with SNLR was: ICG-R15 = 0.36 × TB (umol/L) − 0.78 × ALB(g/L) + 7.783 × SNLR + 0.794 × PT (s) − 0.016 × PLT(/10(9)) − 0.039 × ALT (IU/L) + 0.043 × AST (IU/L) + 23.846. The equivalent formula of serum index was: ICG-R15(2) = 24.665 + 0.382 × TB (umol/L) − 0.799 × ALB(g/L) − 0.025 × PLT(/10(9)) + 0.048 × AST(IU/L) − 0.045 × ALT(IU/L). And the area under the ROC curve (AUC) of predicting ICG-R15 ≥ 10% was 0.861 and 0.857, respectively. CONCLUSION: We found that SNLR was an independent risk factor affecting liver reserve function. Combining with SNLR to evaluate the liver reserve function was better than just basing on serology. BioMed Central 2020-11-12 /pmc/articles/PMC7664104/ /pubmed/33183305 http://dx.doi.org/10.1186/s12893-020-00952-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Zheng, Jinli
Xie, Wei
Huang, Yang
Zhu, Yunfeng
Jiang, Li
The technique of 3D reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (ICG) clearance test to assess the liver reserve function
title The technique of 3D reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (ICG) clearance test to assess the liver reserve function
title_full The technique of 3D reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (ICG) clearance test to assess the liver reserve function
title_fullStr The technique of 3D reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (ICG) clearance test to assess the liver reserve function
title_full_unstemmed The technique of 3D reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (ICG) clearance test to assess the liver reserve function
title_short The technique of 3D reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (ICG) clearance test to assess the liver reserve function
title_sort technique of 3d reconstruction combining with biochemistry to build an equivalent formula of indocyanine green (icg) clearance test to assess the liver reserve function
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7664104/
https://www.ncbi.nlm.nih.gov/pubmed/33183305
http://dx.doi.org/10.1186/s12893-020-00952-z
work_keys_str_mv AT zhengjinli thetechniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT xiewei thetechniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT huangyang thetechniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT zhuyunfeng thetechniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT jiangli thetechniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT zhengjinli techniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT xiewei techniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT huangyang techniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT zhuyunfeng techniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction
AT jiangli techniqueof3dreconstructioncombiningwithbiochemistrytobuildanequivalentformulaofindocyaninegreenicgclearancetesttoassesstheliverreservefunction