Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms

Current standard EN 50463-2 indicates the tests and the requirements to be satisfied for an energy measurement system of a traction unit for railway applications. Some of these tests are to be done with several harmonics superposed on the rated voltage, respectively current. However, no calibration...

Descripción completa

Detalles Bibliográficos
Autores principales: Istrate, Daniela, Khamlichi, Abderrahim, Soccalingame, Soureche, Rovira, Jorge, Fortune, Dominique, Sira, Martin, Simon, Pascual, Garnacho, Fernando
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7664214/
https://www.ncbi.nlm.nih.gov/pubmed/33167602
http://dx.doi.org/10.3390/s20216301
Descripción
Sumario:Current standard EN 50463-2 indicates the tests and the requirements to be satisfied for an energy measurement system of a traction unit for railway applications. Some of these tests are to be done with several harmonics superposed on the rated voltage, respectively current. However, no calibration systems satisfying the standard requirements were available few years ago. The work performed in the EURAMET project “MyRailS” leads to the development of fictive power sources and reference measurement systems described in this paper. Therefore, it is possible to generate distorted 25 kV-50 Hz voltages with harmonics up to 5 kHz and 90° phase-fired currents up to 500 A with harmonics up to 5 kHz. The generated power is measured by developed traceable reference systems with accuracy better than 0.5%.