Cargando…

Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms

Current standard EN 50463-2 indicates the tests and the requirements to be satisfied for an energy measurement system of a traction unit for railway applications. Some of these tests are to be done with several harmonics superposed on the rated voltage, respectively current. However, no calibration...

Descripción completa

Detalles Bibliográficos
Autores principales: Istrate, Daniela, Khamlichi, Abderrahim, Soccalingame, Soureche, Rovira, Jorge, Fortune, Dominique, Sira, Martin, Simon, Pascual, Garnacho, Fernando
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7664214/
https://www.ncbi.nlm.nih.gov/pubmed/33167602
http://dx.doi.org/10.3390/s20216301
_version_ 1783609798002999296
author Istrate, Daniela
Khamlichi, Abderrahim
Soccalingame, Soureche
Rovira, Jorge
Fortune, Dominique
Sira, Martin
Simon, Pascual
Garnacho, Fernando
author_facet Istrate, Daniela
Khamlichi, Abderrahim
Soccalingame, Soureche
Rovira, Jorge
Fortune, Dominique
Sira, Martin
Simon, Pascual
Garnacho, Fernando
author_sort Istrate, Daniela
collection PubMed
description Current standard EN 50463-2 indicates the tests and the requirements to be satisfied for an energy measurement system of a traction unit for railway applications. Some of these tests are to be done with several harmonics superposed on the rated voltage, respectively current. However, no calibration systems satisfying the standard requirements were available few years ago. The work performed in the EURAMET project “MyRailS” leads to the development of fictive power sources and reference measurement systems described in this paper. Therefore, it is possible to generate distorted 25 kV-50 Hz voltages with harmonics up to 5 kHz and 90° phase-fired currents up to 500 A with harmonics up to 5 kHz. The generated power is measured by developed traceable reference systems with accuracy better than 0.5%.
format Online
Article
Text
id pubmed-7664214
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76642142020-11-14 Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms Istrate, Daniela Khamlichi, Abderrahim Soccalingame, Soureche Rovira, Jorge Fortune, Dominique Sira, Martin Simon, Pascual Garnacho, Fernando Sensors (Basel) Article Current standard EN 50463-2 indicates the tests and the requirements to be satisfied for an energy measurement system of a traction unit for railway applications. Some of these tests are to be done with several harmonics superposed on the rated voltage, respectively current. However, no calibration systems satisfying the standard requirements were available few years ago. The work performed in the EURAMET project “MyRailS” leads to the development of fictive power sources and reference measurement systems described in this paper. Therefore, it is possible to generate distorted 25 kV-50 Hz voltages with harmonics up to 5 kHz and 90° phase-fired currents up to 500 A with harmonics up to 5 kHz. The generated power is measured by developed traceable reference systems with accuracy better than 0.5%. MDPI 2020-11-05 /pmc/articles/PMC7664214/ /pubmed/33167602 http://dx.doi.org/10.3390/s20216301 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Istrate, Daniela
Khamlichi, Abderrahim
Soccalingame, Soureche
Rovira, Jorge
Fortune, Dominique
Sira, Martin
Simon, Pascual
Garnacho, Fernando
Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms
title Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms
title_full Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms
title_fullStr Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms
title_full_unstemmed Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms
title_short Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms
title_sort laboratory calibration of energy measurement systems (ems) under ac distorted waveforms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7664214/
https://www.ncbi.nlm.nih.gov/pubmed/33167602
http://dx.doi.org/10.3390/s20216301
work_keys_str_mv AT istratedaniela laboratorycalibrationofenergymeasurementsystemsemsunderacdistortedwaveforms
AT khamlichiabderrahim laboratorycalibrationofenergymeasurementsystemsemsunderacdistortedwaveforms
AT soccalingamesoureche laboratorycalibrationofenergymeasurementsystemsemsunderacdistortedwaveforms
AT rovirajorge laboratorycalibrationofenergymeasurementsystemsemsunderacdistortedwaveforms
AT fortunedominique laboratorycalibrationofenergymeasurementsystemsemsunderacdistortedwaveforms
AT siramartin laboratorycalibrationofenergymeasurementsystemsemsunderacdistortedwaveforms
AT simonpascual laboratorycalibrationofenergymeasurementsystemsemsunderacdistortedwaveforms
AT garnachofernando laboratorycalibrationofenergymeasurementsystemsemsunderacdistortedwaveforms