Effect of Compression on Musical Sound Quality in Cochlear Implant Users
Cochlear implant (CI) users frequently report poor sound quality while listening to music, although the specific parameters responsible for this loss of sound quality remain poorly understood. Audio compression, which reduces the dynamic range (DR) for a given sound, is a ubiquitous component of sig...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Williams And Wilkins
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7664712/ https://www.ncbi.nlm.nih.gov/pubmed/30946137 http://dx.doi.org/10.1097/AUD.0000000000000715 |
_version_ | 1783609890057486336 |
---|---|
author | Gilbert, Melanie Jiradejvong, Patpong Limb, Charles |
author_facet | Gilbert, Melanie Jiradejvong, Patpong Limb, Charles |
author_sort | Gilbert, Melanie |
collection | PubMed |
description | Cochlear implant (CI) users frequently report poor sound quality while listening to music, although the specific parameters responsible for this loss of sound quality remain poorly understood. Audio compression, which reduces the dynamic range (DR) for a given sound, is a ubiquitous component of signal processing used by both CI and hearing aid technology. However, the relative impact of compression for acoustic and electric hearing on music perception has not been well studied, an important consideration especially given that most compression algorithms in CIs were developed to optimize speech perception. The authors hypothesized that normal-hearing (NH) listeners would detect increased levels of compression more easily than CI users, but that both groups would perceive a loss of sound quality with increasing compression levels. DESIGN: The present study utilizes the Cochlear Implant-MUltiple Stimulus with Hidden Reference and Anchor to evaluate the listener sensitivity to increasing levels of compression applied to music stimuli. The Cochlear Implant-MUltiple Stimulus with Hidden Reference and Anchor is a tool used to assess relative changes in the perceived sound quality of music across increasingly degraded listening conditions, in both CI and NH subjects. In this study, the authors applied multiple iterations of an aggressive compression algorithm to the music clips using Adobe Audition. The test conditions included 1, 3, 5, and 20 iterations sound tokens, with the 20-iteration samples serving as the Anchor stimuli. The compressed excerpts were 5 sec in length, with five clips for each of the five common musical genres (i.e., Classical, Jazz, Country, Rock, and Hip-Hop). Subjects were also presented with a Reference excerpt, which was the original music clip without any additional compression applied. CI recipients (n = 7, 11 ears) and NH listeners (n = 10) were asked to rate the sound quality of additionally compressed music as compared to the Reference. RESULTS: Although both NH and CI groups could detect sound quality differences as a function of compression level, the discriminatory ability of the CI group was blunted compared to the NH group. The CI group had less variability in their responses and overall demonstrated reduced sensitivity to deterioration caused by excessive levels of compression. On average, the CI group rated the Anchor condition as only “Slightly worse” than the Reference. The music clips that were most affected by the compression were from Jazz and Hip-Hop genres and less so for Rock and Country clips. Corollary to this was a small but statistically significant impact of DR of the music clips on sound quality ratings, with narrower DR showing an association with poorer ratings. CONCLUSIONS: These results indicate that CI users exhibit less sensitivity to sound quality changes in music attributable to high levels of compression. These findings may account for another contributing factor to the generally poor music perception observed in CI users, particularly when listening to commercially recorded music. |
format | Online Article Text |
id | pubmed-7664712 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Williams And Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-76647122020-11-16 Effect of Compression on Musical Sound Quality in Cochlear Implant Users Gilbert, Melanie Jiradejvong, Patpong Limb, Charles Ear Hear Research Articles Cochlear implant (CI) users frequently report poor sound quality while listening to music, although the specific parameters responsible for this loss of sound quality remain poorly understood. Audio compression, which reduces the dynamic range (DR) for a given sound, is a ubiquitous component of signal processing used by both CI and hearing aid technology. However, the relative impact of compression for acoustic and electric hearing on music perception has not been well studied, an important consideration especially given that most compression algorithms in CIs were developed to optimize speech perception. The authors hypothesized that normal-hearing (NH) listeners would detect increased levels of compression more easily than CI users, but that both groups would perceive a loss of sound quality with increasing compression levels. DESIGN: The present study utilizes the Cochlear Implant-MUltiple Stimulus with Hidden Reference and Anchor to evaluate the listener sensitivity to increasing levels of compression applied to music stimuli. The Cochlear Implant-MUltiple Stimulus with Hidden Reference and Anchor is a tool used to assess relative changes in the perceived sound quality of music across increasingly degraded listening conditions, in both CI and NH subjects. In this study, the authors applied multiple iterations of an aggressive compression algorithm to the music clips using Adobe Audition. The test conditions included 1, 3, 5, and 20 iterations sound tokens, with the 20-iteration samples serving as the Anchor stimuli. The compressed excerpts were 5 sec in length, with five clips for each of the five common musical genres (i.e., Classical, Jazz, Country, Rock, and Hip-Hop). Subjects were also presented with a Reference excerpt, which was the original music clip without any additional compression applied. CI recipients (n = 7, 11 ears) and NH listeners (n = 10) were asked to rate the sound quality of additionally compressed music as compared to the Reference. RESULTS: Although both NH and CI groups could detect sound quality differences as a function of compression level, the discriminatory ability of the CI group was blunted compared to the NH group. The CI group had less variability in their responses and overall demonstrated reduced sensitivity to deterioration caused by excessive levels of compression. On average, the CI group rated the Anchor condition as only “Slightly worse” than the Reference. The music clips that were most affected by the compression were from Jazz and Hip-Hop genres and less so for Rock and Country clips. Corollary to this was a small but statistically significant impact of DR of the music clips on sound quality ratings, with narrower DR showing an association with poorer ratings. CONCLUSIONS: These results indicate that CI users exhibit less sensitivity to sound quality changes in music attributable to high levels of compression. These findings may account for another contributing factor to the generally poor music perception observed in CI users, particularly when listening to commercially recorded music. Williams And Wilkins 2019-10-25 /pmc/articles/PMC7664712/ /pubmed/30946137 http://dx.doi.org/10.1097/AUD.0000000000000715 Text en Copyright © 2019 The Authors. Ear & Hearing is published on behalf of the American Auditory Society, by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Research Articles Gilbert, Melanie Jiradejvong, Patpong Limb, Charles Effect of Compression on Musical Sound Quality in Cochlear Implant Users |
title | Effect of Compression on Musical Sound Quality in Cochlear Implant Users |
title_full | Effect of Compression on Musical Sound Quality in Cochlear Implant Users |
title_fullStr | Effect of Compression on Musical Sound Quality in Cochlear Implant Users |
title_full_unstemmed | Effect of Compression on Musical Sound Quality in Cochlear Implant Users |
title_short | Effect of Compression on Musical Sound Quality in Cochlear Implant Users |
title_sort | effect of compression on musical sound quality in cochlear implant users |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7664712/ https://www.ncbi.nlm.nih.gov/pubmed/30946137 http://dx.doi.org/10.1097/AUD.0000000000000715 |
work_keys_str_mv | AT gilbertmelanie effectofcompressiononmusicalsoundqualityincochlearimplantusers AT jiradejvongpatpong effectofcompressiononmusicalsoundqualityincochlearimplantusers AT limbcharles effectofcompressiononmusicalsoundqualityincochlearimplantusers |