Cargando…

An Energy-Based Method for Orientation Correction of EMG Bracelet Sensors in Hand Gesture Recognition Systems

Hand gesture recognition (HGR) systems using electromyography (EMG) bracelet-type sensors are currently largely used over other HGR technologies. However, bracelets are susceptible to electrode rotation, causing a decrease in HGR performance. In this work, HGR systems with an algorithm for orientati...

Descripción completa

Detalles Bibliográficos
Autores principales: López, Lorena Isabel Barona, Caraguay, Ángel Leonardo Valdivieso, Vimos, Victor H., Zea, Jonathan A., Vásconez, Juan P., Álvarez, Marcelo, Benalcázar, Marco E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7665113/
https://www.ncbi.nlm.nih.gov/pubmed/33171967
http://dx.doi.org/10.3390/s20216327
_version_ 1783609955287302144
author López, Lorena Isabel Barona
Caraguay, Ángel Leonardo Valdivieso
Vimos, Victor H.
Zea, Jonathan A.
Vásconez, Juan P.
Álvarez, Marcelo
Benalcázar, Marco E.
author_facet López, Lorena Isabel Barona
Caraguay, Ángel Leonardo Valdivieso
Vimos, Victor H.
Zea, Jonathan A.
Vásconez, Juan P.
Álvarez, Marcelo
Benalcázar, Marco E.
author_sort López, Lorena Isabel Barona
collection PubMed
description Hand gesture recognition (HGR) systems using electromyography (EMG) bracelet-type sensors are currently largely used over other HGR technologies. However, bracelets are susceptible to electrode rotation, causing a decrease in HGR performance. In this work, HGR systems with an algorithm for orientation correction are proposed. The proposed orientation correction method is based on the computation of the maximum energy channel using a synchronization gesture. Then, the channels of the EMG are rearranged in a new sequence which starts with the maximum energy channel. This new sequence of channels is used for both training and testing. After the EMG channels are rearranged, this signal passes through the following stages: pre-processing, feature extraction, classification, and post-processing. We implemented user-specific and user-general HGR models based on a common architecture which is robust to rotations of the EMG bracelet. Four experiments were performed, taking into account two different metrics which are the classification and recognition accuracy for both models implemented in this work, where each model was evaluated with and without rotation of the bracelet. The classification accuracy measures how well a model predicted which gesture is contained somewhere in a given EMG, whereas recognition accuracy measures how well a model predicted when it occurred, how long it lasted, and which gesture is contained in a given EMG. The results of the experiments (without and with orientation correction) executed show an increase in performance from 44.5% to 81.2% for classification and from 43.3% to 81.3% for recognition in user-general models, while in user-specific models, the results show an increase in performance from 39.8% to 94.9% for classification and from 38.8% to 94.2% for recognition. The results obtained in this work evidence that the proposed method for orientation correction makes the performance of an HGR robust to rotations of the EMG bracelet.
format Online
Article
Text
id pubmed-7665113
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76651132020-11-14 An Energy-Based Method for Orientation Correction of EMG Bracelet Sensors in Hand Gesture Recognition Systems López, Lorena Isabel Barona Caraguay, Ángel Leonardo Valdivieso Vimos, Victor H. Zea, Jonathan A. Vásconez, Juan P. Álvarez, Marcelo Benalcázar, Marco E. Sensors (Basel) Article Hand gesture recognition (HGR) systems using electromyography (EMG) bracelet-type sensors are currently largely used over other HGR technologies. However, bracelets are susceptible to electrode rotation, causing a decrease in HGR performance. In this work, HGR systems with an algorithm for orientation correction are proposed. The proposed orientation correction method is based on the computation of the maximum energy channel using a synchronization gesture. Then, the channels of the EMG are rearranged in a new sequence which starts with the maximum energy channel. This new sequence of channels is used for both training and testing. After the EMG channels are rearranged, this signal passes through the following stages: pre-processing, feature extraction, classification, and post-processing. We implemented user-specific and user-general HGR models based on a common architecture which is robust to rotations of the EMG bracelet. Four experiments were performed, taking into account two different metrics which are the classification and recognition accuracy for both models implemented in this work, where each model was evaluated with and without rotation of the bracelet. The classification accuracy measures how well a model predicted which gesture is contained somewhere in a given EMG, whereas recognition accuracy measures how well a model predicted when it occurred, how long it lasted, and which gesture is contained in a given EMG. The results of the experiments (without and with orientation correction) executed show an increase in performance from 44.5% to 81.2% for classification and from 43.3% to 81.3% for recognition in user-general models, while in user-specific models, the results show an increase in performance from 39.8% to 94.9% for classification and from 38.8% to 94.2% for recognition. The results obtained in this work evidence that the proposed method for orientation correction makes the performance of an HGR robust to rotations of the EMG bracelet. MDPI 2020-11-06 /pmc/articles/PMC7665113/ /pubmed/33171967 http://dx.doi.org/10.3390/s20216327 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
López, Lorena Isabel Barona
Caraguay, Ángel Leonardo Valdivieso
Vimos, Victor H.
Zea, Jonathan A.
Vásconez, Juan P.
Álvarez, Marcelo
Benalcázar, Marco E.
An Energy-Based Method for Orientation Correction of EMG Bracelet Sensors in Hand Gesture Recognition Systems
title An Energy-Based Method for Orientation Correction of EMG Bracelet Sensors in Hand Gesture Recognition Systems
title_full An Energy-Based Method for Orientation Correction of EMG Bracelet Sensors in Hand Gesture Recognition Systems
title_fullStr An Energy-Based Method for Orientation Correction of EMG Bracelet Sensors in Hand Gesture Recognition Systems
title_full_unstemmed An Energy-Based Method for Orientation Correction of EMG Bracelet Sensors in Hand Gesture Recognition Systems
title_short An Energy-Based Method for Orientation Correction of EMG Bracelet Sensors in Hand Gesture Recognition Systems
title_sort energy-based method for orientation correction of emg bracelet sensors in hand gesture recognition systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7665113/
https://www.ncbi.nlm.nih.gov/pubmed/33171967
http://dx.doi.org/10.3390/s20216327
work_keys_str_mv AT lopezlorenaisabelbarona anenergybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT caraguayangelleonardovaldivieso anenergybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT vimosvictorh anenergybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT zeajonathana anenergybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT vasconezjuanp anenergybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT alvarezmarcelo anenergybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT benalcazarmarcoe anenergybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT lopezlorenaisabelbarona energybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT caraguayangelleonardovaldivieso energybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT vimosvictorh energybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT zeajonathana energybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT vasconezjuanp energybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT alvarezmarcelo energybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems
AT benalcazarmarcoe energybasedmethodfororientationcorrectionofemgbraceletsensorsinhandgesturerecognitionsystems