Cargando…
“Purse-String” Capsular Closure for Decreasing Dislocation Rates in Proximal Femur Replacements
Hip joint dislocation is the most common complication after a proximal femur replacement. As the utilization of proximal femur replacements continues to increase, it becomes imperative for surgeons to find the optimal method to decrease postoperative dislocation and its sequelae. These cases often i...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7665252/ https://www.ncbi.nlm.nih.gov/pubmed/33986206 http://dx.doi.org/10.5435/JAAOSGlobal-D-20-00086 |
_version_ | 1783609983889309696 |
---|---|
author | Novack, Thomas A. Patel, Jay N. Hoskins, Tyler Long, Charles Mazzei, Christopher Goyette, David Wittig, James C. |
author_facet | Novack, Thomas A. Patel, Jay N. Hoskins, Tyler Long, Charles Mazzei, Christopher Goyette, David Wittig, James C. |
author_sort | Novack, Thomas A. |
collection | PubMed |
description | Hip joint dislocation is the most common complication after a proximal femur replacement. As the utilization of proximal femur replacements continues to increase, it becomes imperative for surgeons to find the optimal method to decrease postoperative dislocation and its sequelae. These cases often involve extensive soft-tissue deficits that require reconstruction to provide postoperative strength and stability. Patients report good functional outcomes; however, dislocation remains a concern. Although “described” previously in the literature, the authors illustrate the “purse-string” hip joint capsular closure technique to help other surgeons understand it and apply to their practice as deemed necessary. We also present the senior author's results with using a modified version of the “purse-string” hip joint capsular closure technique. |
format | Online Article Text |
id | pubmed-7665252 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer |
record_format | MEDLINE/PubMed |
spelling | pubmed-76652522020-11-16 “Purse-String” Capsular Closure for Decreasing Dislocation Rates in Proximal Femur Replacements Novack, Thomas A. Patel, Jay N. Hoskins, Tyler Long, Charles Mazzei, Christopher Goyette, David Wittig, James C. J Am Acad Orthop Surg Glob Res Rev Surgical Techniques Hip joint dislocation is the most common complication after a proximal femur replacement. As the utilization of proximal femur replacements continues to increase, it becomes imperative for surgeons to find the optimal method to decrease postoperative dislocation and its sequelae. These cases often involve extensive soft-tissue deficits that require reconstruction to provide postoperative strength and stability. Patients report good functional outcomes; however, dislocation remains a concern. Although “described” previously in the literature, the authors illustrate the “purse-string” hip joint capsular closure technique to help other surgeons understand it and apply to their practice as deemed necessary. We also present the senior author's results with using a modified version of the “purse-string” hip joint capsular closure technique. Wolters Kluwer 2020-11-10 /pmc/articles/PMC7665252/ /pubmed/33986206 http://dx.doi.org/10.5435/JAAOSGlobal-D-20-00086 Text en Copyright © 2020 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Orthopaedic Surgeons. This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Surgical Techniques Novack, Thomas A. Patel, Jay N. Hoskins, Tyler Long, Charles Mazzei, Christopher Goyette, David Wittig, James C. “Purse-String” Capsular Closure for Decreasing Dislocation Rates in Proximal Femur Replacements |
title | “Purse-String” Capsular Closure for Decreasing Dislocation Rates in Proximal Femur Replacements |
title_full | “Purse-String” Capsular Closure for Decreasing Dislocation Rates in Proximal Femur Replacements |
title_fullStr | “Purse-String” Capsular Closure for Decreasing Dislocation Rates in Proximal Femur Replacements |
title_full_unstemmed | “Purse-String” Capsular Closure for Decreasing Dislocation Rates in Proximal Femur Replacements |
title_short | “Purse-String” Capsular Closure for Decreasing Dislocation Rates in Proximal Femur Replacements |
title_sort | “purse-string” capsular closure for decreasing dislocation rates in proximal femur replacements |
topic | Surgical Techniques |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7665252/ https://www.ncbi.nlm.nih.gov/pubmed/33986206 http://dx.doi.org/10.5435/JAAOSGlobal-D-20-00086 |
work_keys_str_mv | AT novackthomasa pursestringcapsularclosurefordecreasingdislocationratesinproximalfemurreplacements AT pateljayn pursestringcapsularclosurefordecreasingdislocationratesinproximalfemurreplacements AT hoskinstyler pursestringcapsularclosurefordecreasingdislocationratesinproximalfemurreplacements AT longcharles pursestringcapsularclosurefordecreasingdislocationratesinproximalfemurreplacements AT mazzeichristopher pursestringcapsularclosurefordecreasingdislocationratesinproximalfemurreplacements AT goyettedavid pursestringcapsularclosurefordecreasingdislocationratesinproximalfemurreplacements AT wittigjamesc pursestringcapsularclosurefordecreasingdislocationratesinproximalfemurreplacements |