Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes

PURPOSE: To describe the reliability and the limits of bursa premacularis (BPM) evaluation using a swept source optical coherence tomography (SS-OCT) device with enface and 16 mm-high definition (HD) longitudinal scans. METHODS: 60 eyes of 60 subjects were enrolled and imaged with SS-OCT system (PLE...

Descripción completa

Detalles Bibliográficos
Autores principales: Carpineto, Paolo, D'Aloisio, Rossella, Guarini, Daniele, Iafigliola, Carla, Cerino, Luca, Sciarroni, Elisabetta, Di Antonio, Luca, Clemente, Katia, Di Nicola, Marta, Di Martino, Giuseppe, Mastropasqua, Rodolfo, Toto, Lisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7665913/
https://www.ncbi.nlm.nih.gov/pubmed/33204714
http://dx.doi.org/10.1155/2020/7627128
_version_ 1783610050846130176
author Carpineto, Paolo
D'Aloisio, Rossella
Guarini, Daniele
Iafigliola, Carla
Cerino, Luca
Sciarroni, Elisabetta
Di Antonio, Luca
Clemente, Katia
Di Nicola, Marta
Di Martino, Giuseppe
Mastropasqua, Rodolfo
Toto, Lisa
author_facet Carpineto, Paolo
D'Aloisio, Rossella
Guarini, Daniele
Iafigliola, Carla
Cerino, Luca
Sciarroni, Elisabetta
Di Antonio, Luca
Clemente, Katia
Di Nicola, Marta
Di Martino, Giuseppe
Mastropasqua, Rodolfo
Toto, Lisa
author_sort Carpineto, Paolo
collection PubMed
description PURPOSE: To describe the reliability and the limits of bursa premacularis (BPM) evaluation using a swept source optical coherence tomography (SS-OCT) device with enface and 16 mm-high definition (HD) longitudinal scans. METHODS: 60 eyes of 60 subjects were enrolled and imaged with SS-OCT system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). BPM area was measured using enface scans imported to ImageJ. HD horizontal and vertical longitudinal scans centered at the fovea were used to detect width (W) and central thickness (CT) of BPM at baseline (T(0)) and after 30 minutes (T(30)) performed by two different observers. An enhanced vitreous visualization software provided by the manufacturer of the device was used to highlight vitreous structures. RESULTS: BPM was identifiable in 100% of eyes using both horizontal and vertical longitudinal scans. On horizontal scan, BPM was not entirely measurable in 21.7% and in 18.3% of cases at T(0) and T(30), respectively. On vertical scan, BPM was not entirely measurable in 75.0% and in 81.7% at T(0) and T(30), respectively. No statistically significant differences were found between the two different time measurements with an intraclass correlation coefficient above 70%. Median BPM area was 26.9 (Q(1)-Q(3): 19.5-40.5) mm(2). In en face imaging, the most frequent BPM shape was the boat one. CONCLUSION: SS-OCT is a reliable tool for a detailed quantification and mapping of BPM, and it is able to add useful details about the morphological BPM features in youth population. However, the enhanced visualization of the vitreous structures is still a challenge, also with the most forefront devices.
format Online
Article
Text
id pubmed-7665913
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-76659132020-11-16 Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes Carpineto, Paolo D'Aloisio, Rossella Guarini, Daniele Iafigliola, Carla Cerino, Luca Sciarroni, Elisabetta Di Antonio, Luca Clemente, Katia Di Nicola, Marta Di Martino, Giuseppe Mastropasqua, Rodolfo Toto, Lisa Biomed Res Int Research Article PURPOSE: To describe the reliability and the limits of bursa premacularis (BPM) evaluation using a swept source optical coherence tomography (SS-OCT) device with enface and 16 mm-high definition (HD) longitudinal scans. METHODS: 60 eyes of 60 subjects were enrolled and imaged with SS-OCT system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). BPM area was measured using enface scans imported to ImageJ. HD horizontal and vertical longitudinal scans centered at the fovea were used to detect width (W) and central thickness (CT) of BPM at baseline (T(0)) and after 30 minutes (T(30)) performed by two different observers. An enhanced vitreous visualization software provided by the manufacturer of the device was used to highlight vitreous structures. RESULTS: BPM was identifiable in 100% of eyes using both horizontal and vertical longitudinal scans. On horizontal scan, BPM was not entirely measurable in 21.7% and in 18.3% of cases at T(0) and T(30), respectively. On vertical scan, BPM was not entirely measurable in 75.0% and in 81.7% at T(0) and T(30), respectively. No statistically significant differences were found between the two different time measurements with an intraclass correlation coefficient above 70%. Median BPM area was 26.9 (Q(1)-Q(3): 19.5-40.5) mm(2). In en face imaging, the most frequent BPM shape was the boat one. CONCLUSION: SS-OCT is a reliable tool for a detailed quantification and mapping of BPM, and it is able to add useful details about the morphological BPM features in youth population. However, the enhanced visualization of the vitreous structures is still a challenge, also with the most forefront devices. Hindawi 2020-11-05 /pmc/articles/PMC7665913/ /pubmed/33204714 http://dx.doi.org/10.1155/2020/7627128 Text en Copyright © 2020 Paolo Carpineto et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Carpineto, Paolo
D'Aloisio, Rossella
Guarini, Daniele
Iafigliola, Carla
Cerino, Luca
Sciarroni, Elisabetta
Di Antonio, Luca
Clemente, Katia
Di Nicola, Marta
Di Martino, Giuseppe
Mastropasqua, Rodolfo
Toto, Lisa
Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes
title Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes
title_full Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes
title_fullStr Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes
title_full_unstemmed Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes
title_short Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes
title_sort swept source optical coherence tomography assessment of bursa premacularis in healthy eyes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7665913/
https://www.ncbi.nlm.nih.gov/pubmed/33204714
http://dx.doi.org/10.1155/2020/7627128
work_keys_str_mv AT carpinetopaolo sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT daloisiorossella sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT guarinidaniele sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT iafigliolacarla sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT cerinoluca sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT sciarronielisabetta sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT diantonioluca sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT clementekatia sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT dinicolamarta sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT dimartinogiuseppe sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT mastropasquarodolfo sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes
AT totolisa sweptsourceopticalcoherencetomographyassessmentofbursapremacularisinhealthyeyes