Cargando…

Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study

BACKGROUND: We studied the characteristics and regularity of appropriate insertion points for percutaneous pedicle screw placement in the lumbar spine using C-arm X-ray fluoroscopy. The purpose of this study was to improve the accuracy of percutaneous pedicle screw placement and reduce the incidence...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Wei-Xing, Ding, Wei-Guo, Xu, Bin, Hu, Tian-Hong, Sheng, Hong-Feng, Zhu, Jia-Fu, Zhu, Xiao-Long
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7666764/
https://www.ncbi.nlm.nih.gov/pubmed/33189133
http://dx.doi.org/10.1186/s12891-020-03751-y
_version_ 1783610194582831104
author Xu, Wei-Xing
Ding, Wei-Guo
Xu, Bin
Hu, Tian-Hong
Sheng, Hong-Feng
Zhu, Jia-Fu
Zhu, Xiao-Long
author_facet Xu, Wei-Xing
Ding, Wei-Guo
Xu, Bin
Hu, Tian-Hong
Sheng, Hong-Feng
Zhu, Jia-Fu
Zhu, Xiao-Long
author_sort Xu, Wei-Xing
collection PubMed
description BACKGROUND: We studied the characteristics and regularity of appropriate insertion points for percutaneous pedicle screw placement in the lumbar spine using C-arm X-ray fluoroscopy. The purpose of this study was to improve the accuracy of percutaneous pedicle screw placement and reduce the incidence of superior-level facet joint violation. METHODS: Six normal spinal specimens were included. Three different methods for placing percutaneous pedicle screws in the lumbar spine were applied, including the Roy-Camille method, Magerl method and Weinstein method. The relationships among the insertion point, pedicle projection and proximal facet joint on C-arm X-ray films were studied. The projection morphology of the vertebral pedicle in different segments of the lumbar spine was observed. The relationship between the outer edge of the pedicle projection and the outer edge of the cranial articular process was also studied. The distance between the insertion point and the facet joint (M1), the distance between the insertion point and outer edge of the cranial articular process (M2), and the distance between the insertion point and the projection center of the pedicle (M) were measured. RESULTS: In this study, we found that the projection shape of the vertebral pedicle differed across segments of the lumbar spine: the shape for L1-L3 was oval, and that for L4-L5 was round. The radiographic study showed that the outer edge of the cranial articular process was located on the lateral side of the outer edge of the pedicle projection and did not overlap with the pedicle projection. M for the Weinstein group was larger than that for the Roy-Camille group (P <  0.05). M1 for the Weinstein group was larger than that for the Roy-Camille and Magerl groups (P <  0.05). M2 for the Roy-Camille group was negative, M2 for the Magerl group was 0, and M2 for the Weinstein group was positive. CONCLUSION: Under C-arm X-ray fluoroscopy, we were able to accurately identify the characteristics and regularity of the appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine, which was important for improving the accuracy of percutaneous pedicle screw placement and reducing the incidence of superior-level facet joint violation.
format Online
Article
Text
id pubmed-7666764
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-76667642020-11-16 Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study Xu, Wei-Xing Ding, Wei-Guo Xu, Bin Hu, Tian-Hong Sheng, Hong-Feng Zhu, Jia-Fu Zhu, Xiao-Long BMC Musculoskelet Disord Research Article BACKGROUND: We studied the characteristics and regularity of appropriate insertion points for percutaneous pedicle screw placement in the lumbar spine using C-arm X-ray fluoroscopy. The purpose of this study was to improve the accuracy of percutaneous pedicle screw placement and reduce the incidence of superior-level facet joint violation. METHODS: Six normal spinal specimens were included. Three different methods for placing percutaneous pedicle screws in the lumbar spine were applied, including the Roy-Camille method, Magerl method and Weinstein method. The relationships among the insertion point, pedicle projection and proximal facet joint on C-arm X-ray films were studied. The projection morphology of the vertebral pedicle in different segments of the lumbar spine was observed. The relationship between the outer edge of the pedicle projection and the outer edge of the cranial articular process was also studied. The distance between the insertion point and the facet joint (M1), the distance between the insertion point and outer edge of the cranial articular process (M2), and the distance between the insertion point and the projection center of the pedicle (M) were measured. RESULTS: In this study, we found that the projection shape of the vertebral pedicle differed across segments of the lumbar spine: the shape for L1-L3 was oval, and that for L4-L5 was round. The radiographic study showed that the outer edge of the cranial articular process was located on the lateral side of the outer edge of the pedicle projection and did not overlap with the pedicle projection. M for the Weinstein group was larger than that for the Roy-Camille group (P <  0.05). M1 for the Weinstein group was larger than that for the Roy-Camille and Magerl groups (P <  0.05). M2 for the Roy-Camille group was negative, M2 for the Magerl group was 0, and M2 for the Weinstein group was positive. CONCLUSION: Under C-arm X-ray fluoroscopy, we were able to accurately identify the characteristics and regularity of the appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine, which was important for improving the accuracy of percutaneous pedicle screw placement and reducing the incidence of superior-level facet joint violation. BioMed Central 2020-11-14 /pmc/articles/PMC7666764/ /pubmed/33189133 http://dx.doi.org/10.1186/s12891-020-03751-y Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Xu, Wei-Xing
Ding, Wei-Guo
Xu, Bin
Hu, Tian-Hong
Sheng, Hong-Feng
Zhu, Jia-Fu
Zhu, Xiao-Long
Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
title Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
title_full Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
title_fullStr Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
title_full_unstemmed Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
title_short Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
title_sort appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7666764/
https://www.ncbi.nlm.nih.gov/pubmed/33189133
http://dx.doi.org/10.1186/s12891-020-03751-y
work_keys_str_mv AT xuweixing appropriateinsertionpointforpercutaneouspediclescrewplacementinthelumbarspineusingcarmfluoroscopyacadavericstudy
AT dingweiguo appropriateinsertionpointforpercutaneouspediclescrewplacementinthelumbarspineusingcarmfluoroscopyacadavericstudy
AT xubin appropriateinsertionpointforpercutaneouspediclescrewplacementinthelumbarspineusingcarmfluoroscopyacadavericstudy
AT hutianhong appropriateinsertionpointforpercutaneouspediclescrewplacementinthelumbarspineusingcarmfluoroscopyacadavericstudy
AT shenghongfeng appropriateinsertionpointforpercutaneouspediclescrewplacementinthelumbarspineusingcarmfluoroscopyacadavericstudy
AT zhujiafu appropriateinsertionpointforpercutaneouspediclescrewplacementinthelumbarspineusingcarmfluoroscopyacadavericstudy
AT zhuxiaolong appropriateinsertionpointforpercutaneouspediclescrewplacementinthelumbarspineusingcarmfluoroscopyacadavericstudy