Cargando…
The Universal Entry Point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis
PURPOSE: Stable slipped capital femoral epiphysis (SCFE) is often treated with in situ pinning, with the current gold standard being stabilization with a screw perpendicular to the physis. However, this can lead to impingement and a potentially unstable construct. In this study we model the biomecha...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Editorial Society of Bone & Joint Surgery
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7666795/ https://www.ncbi.nlm.nih.gov/pubmed/33204342 http://dx.doi.org/10.1302/1863-2548.14.190178 |
_version_ | 1783610201584173056 |
---|---|
author | Lee, Jillian Lillia, Jonathon A. Bellemore, Jeremy M. Little, David G. Cheng, Tegan L. |
author_facet | Lee, Jillian Lillia, Jonathon A. Bellemore, Jeremy M. Little, David G. Cheng, Tegan L. |
author_sort | Lee, Jillian |
collection | PubMed |
description | PURPOSE: Stable slipped capital femoral epiphysis (SCFE) is often treated with in situ pinning, with the current gold standard being stabilization with a screw perpendicular to the physis. However, this can lead to impingement and a potentially unstable construct. In this study we model the biomechanical effect of two screw positions used for SCFE fixation. We hypothesize that single screw fixation into the centre of the femoral head from the anterior intertrochanteric line (the Universal Entry Point or UEP) provides a more stable construct than single screw fixation perpendicular to the physis with an anterior starting point. METHODS: Sawbone models of moderate SCFE were used to mechanically test the two screw constructs and an unfixed control group. Models were loaded to failure with a shear load applied through the physis in an Instron mechanical tester. The primary outcomes were maximum load, stiffness and energy to failure. RESULTS: Screw fixation into the centre of the femoral head from the UEP resulted in a greater load to failure (+19%), stiffness (+13%) and energy to failure (+45%) than screw fixation perpendicular to the physis. CONCLUSIONS: In this sawbone construct, screw fixation into the centre of the femoral head from the UEP provides greater biomechanical stability than screw fixation perpendicular to the physis. This approach may also benefit by avoiding an intracapsular entry point in soft metaphyseal bone and subsequent risk of impingement and loss of position. |
format | Online Article Text |
id | pubmed-7666795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The British Editorial Society of Bone & Joint Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-76667952020-11-16 The Universal Entry Point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis Lee, Jillian Lillia, Jonathon A. Bellemore, Jeremy M. Little, David G. Cheng, Tegan L. J Child Orthop Basic Science PURPOSE: Stable slipped capital femoral epiphysis (SCFE) is often treated with in situ pinning, with the current gold standard being stabilization with a screw perpendicular to the physis. However, this can lead to impingement and a potentially unstable construct. In this study we model the biomechanical effect of two screw positions used for SCFE fixation. We hypothesize that single screw fixation into the centre of the femoral head from the anterior intertrochanteric line (the Universal Entry Point or UEP) provides a more stable construct than single screw fixation perpendicular to the physis with an anterior starting point. METHODS: Sawbone models of moderate SCFE were used to mechanically test the two screw constructs and an unfixed control group. Models were loaded to failure with a shear load applied through the physis in an Instron mechanical tester. The primary outcomes were maximum load, stiffness and energy to failure. RESULTS: Screw fixation into the centre of the femoral head from the UEP resulted in a greater load to failure (+19%), stiffness (+13%) and energy to failure (+45%) than screw fixation perpendicular to the physis. CONCLUSIONS: In this sawbone construct, screw fixation into the centre of the femoral head from the UEP provides greater biomechanical stability than screw fixation perpendicular to the physis. This approach may also benefit by avoiding an intracapsular entry point in soft metaphyseal bone and subsequent risk of impingement and loss of position. The British Editorial Society of Bone & Joint Surgery 2020-10-01 /pmc/articles/PMC7666795/ /pubmed/33204342 http://dx.doi.org/10.1302/1863-2548.14.190178 Text en Copyright © 2020, The author(s) http://creativecommons.org/licenses/by-nc/4.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution-Non Commercial 4.0 International (CC BY-NC 4.0) licence (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed. |
spellingShingle | Basic Science Lee, Jillian Lillia, Jonathon A. Bellemore, Jeremy M. Little, David G. Cheng, Tegan L. The Universal Entry Point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis |
title | The Universal Entry Point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis |
title_full | The Universal Entry Point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis |
title_fullStr | The Universal Entry Point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis |
title_full_unstemmed | The Universal Entry Point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis |
title_short | The Universal Entry Point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis |
title_sort | universal entry point with oblique screw is superior to fixation perpendicular to the physis in moderate slipped capital femoral epiphysis |
topic | Basic Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7666795/ https://www.ncbi.nlm.nih.gov/pubmed/33204342 http://dx.doi.org/10.1302/1863-2548.14.190178 |
work_keys_str_mv | AT leejillian theuniversalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT lilliajonathona theuniversalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT bellemorejeremym theuniversalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT littledavidg theuniversalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT chengteganl theuniversalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT leejillian universalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT lilliajonathona universalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT bellemorejeremym universalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT littledavidg universalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis AT chengteganl universalentrypointwithobliquescrewissuperiortofixationperpendiculartothephysisinmoderateslippedcapitalfemoralepiphysis |