Cargando…

Pravastatin Transdermal Patches: Effect of The Formulation and Two Different Lengths of Microneedles on In-vitro Percutaneous Absorption Studies

Transdermal patches loaded with pravastatin was previously characterized in another published study by Serrano-Castañeda et al; 2015. These transdermal patches (TP) were generated by the plate casting technique, the in-vitro percutaneous absorption studies of TP were evaluated for three different fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Castañeda, Pablo Serrano, Escobar-Chávez, José Juan, Vázquez, Johana Arroyo, Cruz, Isabel Marlen Rodríguez, Contreras, Luz María Melgoza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shaheed Beheshti University of Medical Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7667542/
https://www.ncbi.nlm.nih.gov/pubmed/33224217
http://dx.doi.org/10.22037/ijpr.2019.1100914
Descripción
Sumario:Transdermal patches loaded with pravastatin was previously characterized in another published study by Serrano-Castañeda et al; 2015. These transdermal patches (TP) were generated by the plate casting technique, the in-vitro percutaneous absorption studies of TP were evaluated for three different formulations with different quantities of Pluronic F-127 (PF-127): i) without PF-127 (TP W), ii) 1% of PF-127 (TP 1%), and iii) 3% of PF-127 (TP 3%) using solid microneedles as a penetration enhancer with two different lengths: i) 0.25 mm and ii) 2.25 mm and iii) in-vitro permeation studies by passive diffusion. The fluxes (F), time lag (t(Lag)) and permeability constants (Kp) for each formulation were: TP W (F:38.5µg/cm(2)*h, t(Lag):18.97h and Kp:5.9x10(-3) cm/h), TP W with microneedles of 0.25 mm (F:103.3 µg/cm(2)*h, t(Lag): 20.76 h and Kp: 0.0158 cm/h), TP W and microneedles of 2.25 mm (F:105.2µg/cm(2)*h, t(Lag): 21.16 h and Kp: 0.0159cm/h), TP 1% (F:90 µg/cm(2)*h, t(Lag): 19.48 h and Kp: 0.0137 cm/h), TP 1% with microneedles of 0.25 mm (F:111.4µg/cm(2)*h, t(Lag):19.11h and Kp:0.017cm/h), and TP 1% with microneedles of 2.25 mm (F:115.2µg/cm(2)*h, t(Lag):16.73h and Kp:0.017cm/h), TP 3% (F:40.9µg/cm(2)*h, t(Lag):20.45h and Kp:0.0062 cm/h), TP 3% with microneedles of 0.25 mm (F:67.1 µg/cm(2)*h, t(Lag): 21.79h and Kp:0.0102cm/h) and TP 3% with microneedles of 2.25 (F:70.5 µg/cm(2)*h, t(Lag):20.44h and Kp:0.0107cm/h). Results show that the formulation of TP affects the pravastatina flux and Kp parameters, however the length of microneedles only has important effect on t(Lag).