Cargando…

Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry

PURPOSE: This multicenter, prospective registry evaluated the comparative safety and efficacy of left atrial appendage occlusion (LAAO) using the Watchman device (WD) and the Amplatzer Cardiac Plug (ACP) in patients with nonvalvular atrial fibrillation (NVAF) in real-world clinical practice in Russi...

Descripción completa

Detalles Bibliográficos
Autores principales: Davtyan, Karapet, Simonyan, Georgiy, Topchyan, Arpi, Kalemberg, Andrey, Romanov, Alexander, Shabanov, Vitaliy, Lebedev, Dmitriy, Gureev, Sergey, Miller, Yulia, Merkulov, Evgeniy, Pevzner, Dmitry, Mozgovoy, Pavel, Ufimtsev, Vladimir, Boytsov, Sergey, Drapkina, Oksana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669348/
https://www.ncbi.nlm.nih.gov/pubmed/33224976
http://dx.doi.org/10.1155/2020/2352648
_version_ 1783610550181167104
author Davtyan, Karapet
Simonyan, Georgiy
Topchyan, Arpi
Kalemberg, Andrey
Romanov, Alexander
Shabanov, Vitaliy
Lebedev, Dmitriy
Gureev, Sergey
Miller, Yulia
Merkulov, Evgeniy
Pevzner, Dmitry
Mozgovoy, Pavel
Ufimtsev, Vladimir
Boytsov, Sergey
Drapkina, Oksana
author_facet Davtyan, Karapet
Simonyan, Georgiy
Topchyan, Arpi
Kalemberg, Andrey
Romanov, Alexander
Shabanov, Vitaliy
Lebedev, Dmitriy
Gureev, Sergey
Miller, Yulia
Merkulov, Evgeniy
Pevzner, Dmitry
Mozgovoy, Pavel
Ufimtsev, Vladimir
Boytsov, Sergey
Drapkina, Oksana
author_sort Davtyan, Karapet
collection PubMed
description PURPOSE: This multicenter, prospective registry evaluated the comparative safety and efficacy of left atrial appendage occlusion (LAAO) using the Watchman device (WD) and the Amplatzer Cardiac Plug (ACP) in patients with nonvalvular atrial fibrillation (NVAF) in real-world clinical practice in Russia. METHODS: The study included data from 200 consecutive NVAF patients (66.8 ± 7.8 years, 44.5% female, median CHA2DS2VASc 4, median HAS-BLED 3) who had undergone LAAO implantation using WD (n = 108) or ACP (n = 92) from September 2015 to December 2017 in 5 medical centers in Russia. The primary safety endpoint was the procedure-related major adverse events, and the primary efficacy endpoint was the composite of thromboembolic events, device thrombosis, hemorrhagic events, and unexplained death during the 12-month follow-up. RESULTS: Successful LAAO was performed in all 92 (100%) patients with ACP and 105 (97.2%) with WD (p = 0.053). At 12 months, primary safety endpoint occurred in 6.5% of patients in the ACP group with no events in the WD group (6.5% vs. 0%, p = 0.008). During the 12-month follow-up, the primary efficacy endpoint has occurred in 8.3% of patients in the WD group (n = 9) and 1.1% of patients in the ACP group (n = 1) (p = 0.016). CONCLUSIONS: In this multicenter prospective registry, LAA closure with the WD was associated with significantly higher thromboembolic events rate in NVAF patients. Patients, receiving the ACP, had more procedure-related major adverse events. However, further multicenter studies are necessary to evaluate these findings.
format Online
Article
Text
id pubmed-7669348
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-76693482020-11-19 Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry Davtyan, Karapet Simonyan, Georgiy Topchyan, Arpi Kalemberg, Andrey Romanov, Alexander Shabanov, Vitaliy Lebedev, Dmitriy Gureev, Sergey Miller, Yulia Merkulov, Evgeniy Pevzner, Dmitry Mozgovoy, Pavel Ufimtsev, Vladimir Boytsov, Sergey Drapkina, Oksana Biomed Res Int Research Article PURPOSE: This multicenter, prospective registry evaluated the comparative safety and efficacy of left atrial appendage occlusion (LAAO) using the Watchman device (WD) and the Amplatzer Cardiac Plug (ACP) in patients with nonvalvular atrial fibrillation (NVAF) in real-world clinical practice in Russia. METHODS: The study included data from 200 consecutive NVAF patients (66.8 ± 7.8 years, 44.5% female, median CHA2DS2VASc 4, median HAS-BLED 3) who had undergone LAAO implantation using WD (n = 108) or ACP (n = 92) from September 2015 to December 2017 in 5 medical centers in Russia. The primary safety endpoint was the procedure-related major adverse events, and the primary efficacy endpoint was the composite of thromboembolic events, device thrombosis, hemorrhagic events, and unexplained death during the 12-month follow-up. RESULTS: Successful LAAO was performed in all 92 (100%) patients with ACP and 105 (97.2%) with WD (p = 0.053). At 12 months, primary safety endpoint occurred in 6.5% of patients in the ACP group with no events in the WD group (6.5% vs. 0%, p = 0.008). During the 12-month follow-up, the primary efficacy endpoint has occurred in 8.3% of patients in the WD group (n = 9) and 1.1% of patients in the ACP group (n = 1) (p = 0.016). CONCLUSIONS: In this multicenter prospective registry, LAA closure with the WD was associated with significantly higher thromboembolic events rate in NVAF patients. Patients, receiving the ACP, had more procedure-related major adverse events. However, further multicenter studies are necessary to evaluate these findings. Hindawi 2020-11-07 /pmc/articles/PMC7669348/ /pubmed/33224976 http://dx.doi.org/10.1155/2020/2352648 Text en Copyright © 2020 Karapet Davtyan et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Davtyan, Karapet
Simonyan, Georgiy
Topchyan, Arpi
Kalemberg, Andrey
Romanov, Alexander
Shabanov, Vitaliy
Lebedev, Dmitriy
Gureev, Sergey
Miller, Yulia
Merkulov, Evgeniy
Pevzner, Dmitry
Mozgovoy, Pavel
Ufimtsev, Vladimir
Boytsov, Sergey
Drapkina, Oksana
Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry
title Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry
title_full Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry
title_fullStr Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry
title_full_unstemmed Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry
title_short Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry
title_sort comparative safety and efficacy of left atrial appendage occlusion with the watchman device and amplatzer cardiac plug: results of the russian national registry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669348/
https://www.ncbi.nlm.nih.gov/pubmed/33224976
http://dx.doi.org/10.1155/2020/2352648
work_keys_str_mv AT davtyankarapet comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT simonyangeorgiy comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT topchyanarpi comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT kalembergandrey comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT romanovalexander comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT shabanovvitaliy comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT lebedevdmitriy comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT gureevsergey comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT milleryulia comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT merkulovevgeniy comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT pevznerdmitry comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT mozgovoypavel comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT ufimtsevvladimir comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT boytsovsergey comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry
AT drapkinaoksana comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry