Cargando…
Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry
PURPOSE: This multicenter, prospective registry evaluated the comparative safety and efficacy of left atrial appendage occlusion (LAAO) using the Watchman device (WD) and the Amplatzer Cardiac Plug (ACP) in patients with nonvalvular atrial fibrillation (NVAF) in real-world clinical practice in Russi...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669348/ https://www.ncbi.nlm.nih.gov/pubmed/33224976 http://dx.doi.org/10.1155/2020/2352648 |
_version_ | 1783610550181167104 |
---|---|
author | Davtyan, Karapet Simonyan, Georgiy Topchyan, Arpi Kalemberg, Andrey Romanov, Alexander Shabanov, Vitaliy Lebedev, Dmitriy Gureev, Sergey Miller, Yulia Merkulov, Evgeniy Pevzner, Dmitry Mozgovoy, Pavel Ufimtsev, Vladimir Boytsov, Sergey Drapkina, Oksana |
author_facet | Davtyan, Karapet Simonyan, Georgiy Topchyan, Arpi Kalemberg, Andrey Romanov, Alexander Shabanov, Vitaliy Lebedev, Dmitriy Gureev, Sergey Miller, Yulia Merkulov, Evgeniy Pevzner, Dmitry Mozgovoy, Pavel Ufimtsev, Vladimir Boytsov, Sergey Drapkina, Oksana |
author_sort | Davtyan, Karapet |
collection | PubMed |
description | PURPOSE: This multicenter, prospective registry evaluated the comparative safety and efficacy of left atrial appendage occlusion (LAAO) using the Watchman device (WD) and the Amplatzer Cardiac Plug (ACP) in patients with nonvalvular atrial fibrillation (NVAF) in real-world clinical practice in Russia. METHODS: The study included data from 200 consecutive NVAF patients (66.8 ± 7.8 years, 44.5% female, median CHA2DS2VASc 4, median HAS-BLED 3) who had undergone LAAO implantation using WD (n = 108) or ACP (n = 92) from September 2015 to December 2017 in 5 medical centers in Russia. The primary safety endpoint was the procedure-related major adverse events, and the primary efficacy endpoint was the composite of thromboembolic events, device thrombosis, hemorrhagic events, and unexplained death during the 12-month follow-up. RESULTS: Successful LAAO was performed in all 92 (100%) patients with ACP and 105 (97.2%) with WD (p = 0.053). At 12 months, primary safety endpoint occurred in 6.5% of patients in the ACP group with no events in the WD group (6.5% vs. 0%, p = 0.008). During the 12-month follow-up, the primary efficacy endpoint has occurred in 8.3% of patients in the WD group (n = 9) and 1.1% of patients in the ACP group (n = 1) (p = 0.016). CONCLUSIONS: In this multicenter prospective registry, LAA closure with the WD was associated with significantly higher thromboembolic events rate in NVAF patients. Patients, receiving the ACP, had more procedure-related major adverse events. However, further multicenter studies are necessary to evaluate these findings. |
format | Online Article Text |
id | pubmed-7669348 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-76693482020-11-19 Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry Davtyan, Karapet Simonyan, Georgiy Topchyan, Arpi Kalemberg, Andrey Romanov, Alexander Shabanov, Vitaliy Lebedev, Dmitriy Gureev, Sergey Miller, Yulia Merkulov, Evgeniy Pevzner, Dmitry Mozgovoy, Pavel Ufimtsev, Vladimir Boytsov, Sergey Drapkina, Oksana Biomed Res Int Research Article PURPOSE: This multicenter, prospective registry evaluated the comparative safety and efficacy of left atrial appendage occlusion (LAAO) using the Watchman device (WD) and the Amplatzer Cardiac Plug (ACP) in patients with nonvalvular atrial fibrillation (NVAF) in real-world clinical practice in Russia. METHODS: The study included data from 200 consecutive NVAF patients (66.8 ± 7.8 years, 44.5% female, median CHA2DS2VASc 4, median HAS-BLED 3) who had undergone LAAO implantation using WD (n = 108) or ACP (n = 92) from September 2015 to December 2017 in 5 medical centers in Russia. The primary safety endpoint was the procedure-related major adverse events, and the primary efficacy endpoint was the composite of thromboembolic events, device thrombosis, hemorrhagic events, and unexplained death during the 12-month follow-up. RESULTS: Successful LAAO was performed in all 92 (100%) patients with ACP and 105 (97.2%) with WD (p = 0.053). At 12 months, primary safety endpoint occurred in 6.5% of patients in the ACP group with no events in the WD group (6.5% vs. 0%, p = 0.008). During the 12-month follow-up, the primary efficacy endpoint has occurred in 8.3% of patients in the WD group (n = 9) and 1.1% of patients in the ACP group (n = 1) (p = 0.016). CONCLUSIONS: In this multicenter prospective registry, LAA closure with the WD was associated with significantly higher thromboembolic events rate in NVAF patients. Patients, receiving the ACP, had more procedure-related major adverse events. However, further multicenter studies are necessary to evaluate these findings. Hindawi 2020-11-07 /pmc/articles/PMC7669348/ /pubmed/33224976 http://dx.doi.org/10.1155/2020/2352648 Text en Copyright © 2020 Karapet Davtyan et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Davtyan, Karapet Simonyan, Georgiy Topchyan, Arpi Kalemberg, Andrey Romanov, Alexander Shabanov, Vitaliy Lebedev, Dmitriy Gureev, Sergey Miller, Yulia Merkulov, Evgeniy Pevzner, Dmitry Mozgovoy, Pavel Ufimtsev, Vladimir Boytsov, Sergey Drapkina, Oksana Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry |
title | Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry |
title_full | Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry |
title_fullStr | Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry |
title_full_unstemmed | Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry |
title_short | Comparative Safety and Efficacy of Left Atrial Appendage Occlusion with the Watchman Device and Amplatzer Cardiac Plug: Results of the Russian National Registry |
title_sort | comparative safety and efficacy of left atrial appendage occlusion with the watchman device and amplatzer cardiac plug: results of the russian national registry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669348/ https://www.ncbi.nlm.nih.gov/pubmed/33224976 http://dx.doi.org/10.1155/2020/2352648 |
work_keys_str_mv | AT davtyankarapet comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT simonyangeorgiy comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT topchyanarpi comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT kalembergandrey comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT romanovalexander comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT shabanovvitaliy comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT lebedevdmitriy comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT gureevsergey comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT milleryulia comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT merkulovevgeniy comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT pevznerdmitry comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT mozgovoypavel comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT ufimtsevvladimir comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT boytsovsergey comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry AT drapkinaoksana comparativesafetyandefficacyofleftatrialappendageocclusionwiththewatchmandeviceandamplatzercardiacplugresultsoftherussiannationalregistry |