Cargando…

Simultaneous X-ray Video-Fluoroscopy and Pulsed Ultrasound Velocimetry Analyses of the Pharyngeal Phase of Swallowing of Boluses with Different Rheological Properties

The Ultrasound Velocity Profiling (UVP) technique allows real-time, non-invasive flow mapping of a fluid along a 1D-measuring line. This study explores the possibility of using the UVP technique and X-ray video-fluoroscopy (XVF) to elucidate the deglutition process with the focus on bolus rheology....

Descripción completa

Detalles Bibliográficos
Autores principales: Qazi, Waqas M., Ekberg, Olle, Wiklund, Johan, Mansoor, Rashid, Stading, Mats
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669789/
https://www.ncbi.nlm.nih.gov/pubmed/32048021
http://dx.doi.org/10.1007/s00455-020-10092-4
_version_ 1783610608398106624
author Qazi, Waqas M.
Ekberg, Olle
Wiklund, Johan
Mansoor, Rashid
Stading, Mats
author_facet Qazi, Waqas M.
Ekberg, Olle
Wiklund, Johan
Mansoor, Rashid
Stading, Mats
author_sort Qazi, Waqas M.
collection PubMed
description The Ultrasound Velocity Profiling (UVP) technique allows real-time, non-invasive flow mapping of a fluid along a 1D-measuring line. This study explores the possibility of using the UVP technique and X-ray video-fluoroscopy (XVF) to elucidate the deglutition process with the focus on bolus rheology. By positioning the UVP probe so that the pulsed ultrasonic beam passes behind the air-filled trachea, the bolus flow in the pharynx can be measured. Healthy subjects in a clinical study swallowed fluids with different rheological properties: Newtonian (constant shear viscosity and non-elastic); Boger (constant shear viscosity and elastic); and shear thinning (shear rate-dependent shear viscosity and elastic). The results from both the UVP and XVF reveal higher velocities for the shear thinning fluid, followed by the Boger and the Newtonian fluids, demonstrating that the UVP method has equivalent sensitivities for detecting the velocities of fluids with different rheological properties. The velocity of the contraction wave that clears the pharynx was measured in the UVP and found to be independent of bolus rheology. The results show that UVP not only assesses accurately the fluid velocity in a bolus flow, but it can also monitor the structural changes that take place in response to a bolus flow, with the added advantage of being a completely non-invasive technique that does not require the introduction of contrast media. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00455-020-10092-4) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7669789
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-76697892020-11-17 Simultaneous X-ray Video-Fluoroscopy and Pulsed Ultrasound Velocimetry Analyses of the Pharyngeal Phase of Swallowing of Boluses with Different Rheological Properties Qazi, Waqas M. Ekberg, Olle Wiklund, Johan Mansoor, Rashid Stading, Mats Dysphagia Review The Ultrasound Velocity Profiling (UVP) technique allows real-time, non-invasive flow mapping of a fluid along a 1D-measuring line. This study explores the possibility of using the UVP technique and X-ray video-fluoroscopy (XVF) to elucidate the deglutition process with the focus on bolus rheology. By positioning the UVP probe so that the pulsed ultrasonic beam passes behind the air-filled trachea, the bolus flow in the pharynx can be measured. Healthy subjects in a clinical study swallowed fluids with different rheological properties: Newtonian (constant shear viscosity and non-elastic); Boger (constant shear viscosity and elastic); and shear thinning (shear rate-dependent shear viscosity and elastic). The results from both the UVP and XVF reveal higher velocities for the shear thinning fluid, followed by the Boger and the Newtonian fluids, demonstrating that the UVP method has equivalent sensitivities for detecting the velocities of fluids with different rheological properties. The velocity of the contraction wave that clears the pharynx was measured in the UVP and found to be independent of bolus rheology. The results show that UVP not only assesses accurately the fluid velocity in a bolus flow, but it can also monitor the structural changes that take place in response to a bolus flow, with the added advantage of being a completely non-invasive technique that does not require the introduction of contrast media. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00455-020-10092-4) contains supplementary material, which is available to authorized users. Springer US 2020-02-11 2020 /pmc/articles/PMC7669789/ /pubmed/32048021 http://dx.doi.org/10.1007/s00455-020-10092-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Review
Qazi, Waqas M.
Ekberg, Olle
Wiklund, Johan
Mansoor, Rashid
Stading, Mats
Simultaneous X-ray Video-Fluoroscopy and Pulsed Ultrasound Velocimetry Analyses of the Pharyngeal Phase of Swallowing of Boluses with Different Rheological Properties
title Simultaneous X-ray Video-Fluoroscopy and Pulsed Ultrasound Velocimetry Analyses of the Pharyngeal Phase of Swallowing of Boluses with Different Rheological Properties
title_full Simultaneous X-ray Video-Fluoroscopy and Pulsed Ultrasound Velocimetry Analyses of the Pharyngeal Phase of Swallowing of Boluses with Different Rheological Properties
title_fullStr Simultaneous X-ray Video-Fluoroscopy and Pulsed Ultrasound Velocimetry Analyses of the Pharyngeal Phase of Swallowing of Boluses with Different Rheological Properties
title_full_unstemmed Simultaneous X-ray Video-Fluoroscopy and Pulsed Ultrasound Velocimetry Analyses of the Pharyngeal Phase of Swallowing of Boluses with Different Rheological Properties
title_short Simultaneous X-ray Video-Fluoroscopy and Pulsed Ultrasound Velocimetry Analyses of the Pharyngeal Phase of Swallowing of Boluses with Different Rheological Properties
title_sort simultaneous x-ray video-fluoroscopy and pulsed ultrasound velocimetry analyses of the pharyngeal phase of swallowing of boluses with different rheological properties
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669789/
https://www.ncbi.nlm.nih.gov/pubmed/32048021
http://dx.doi.org/10.1007/s00455-020-10092-4
work_keys_str_mv AT qaziwaqasm simultaneousxrayvideofluoroscopyandpulsedultrasoundvelocimetryanalysesofthepharyngealphaseofswallowingofboluseswithdifferentrheologicalproperties
AT ekbergolle simultaneousxrayvideofluoroscopyandpulsedultrasoundvelocimetryanalysesofthepharyngealphaseofswallowingofboluseswithdifferentrheologicalproperties
AT wiklundjohan simultaneousxrayvideofluoroscopyandpulsedultrasoundvelocimetryanalysesofthepharyngealphaseofswallowingofboluseswithdifferentrheologicalproperties
AT mansoorrashid simultaneousxrayvideofluoroscopyandpulsedultrasoundvelocimetryanalysesofthepharyngealphaseofswallowingofboluseswithdifferentrheologicalproperties
AT stadingmats simultaneousxrayvideofluoroscopyandpulsedultrasoundvelocimetryanalysesofthepharyngealphaseofswallowingofboluseswithdifferentrheologicalproperties