Cargando…

Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T

OBJECTIVES: To propose and validate a novel imaging sequence that uses a single breath-hold whole-heart 3D T1 saturation recovery compressed SENSE rapid acquisition (SACORA) at 3T. METHODS: The proposed sequence combines flexible saturation time sampling, compressed SENSE, and sharing of saturation...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferreira da Silva, Tiago, Galan-Arriola, Carlos, Montesinos, Paula, López-Martín, Gonzalo Javier, Desco, Manuel, Fuster, Valentín, Ibáñez, Borja, Sanchez-Gonzalez, Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669807/
https://www.ncbi.nlm.nih.gov/pubmed/32410103
http://dx.doi.org/10.1007/s10334-020-00848-2
_version_ 1783610612647985152
author Ferreira da Silva, Tiago
Galan-Arriola, Carlos
Montesinos, Paula
López-Martín, Gonzalo Javier
Desco, Manuel
Fuster, Valentín
Ibáñez, Borja
Sanchez-Gonzalez, Javier
author_facet Ferreira da Silva, Tiago
Galan-Arriola, Carlos
Montesinos, Paula
López-Martín, Gonzalo Javier
Desco, Manuel
Fuster, Valentín
Ibáñez, Borja
Sanchez-Gonzalez, Javier
author_sort Ferreira da Silva, Tiago
collection PubMed
description OBJECTIVES: To propose and validate a novel imaging sequence that uses a single breath-hold whole-heart 3D T1 saturation recovery compressed SENSE rapid acquisition (SACORA) at 3T. METHODS: The proposed sequence combines flexible saturation time sampling, compressed SENSE, and sharing of saturation pulses between two readouts acquired at different RR intervals. The sequence was compared with a 3D saturation recovery single-shot acquisition (SASHA) implementation with phantom and in vivo experiments (pre and post contrast; 7 pigs) and was validated against the reference inversion recovery spin echo (IR-SE) sequence in phantom experiments. RESULTS: Phantom experiments showed that the T1 maps acquired by 3D SACORA and 3D SASHA agree well with IR-SE. In vivo experiments showed that the pre-contrast and post-contrast T1 maps acquired by 3D SACORA are comparable to the corresponding 3D SASHA maps, despite the shorter acquisition time (15s vs. 188s, for a heart rate of 60 bpm). Mean septal pre-contrast T1 was 1453 ± 44 ms with 3D SACORA and 1460 ± 60 ms with 3D SASHA. Mean septal post-contrast T1 was 824 ± 66 ms and 824 ± 60 ms. CONCLUSION: 3D SACORA acquires 3D T1 maps in 15 heart beats (heart rate, 60 bpm) at 3T. In addition to its short acquisition time, the sequence achieves good T1 estimation precision and accuracy. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10334-020-00848-2) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7669807
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-76698072020-11-17 Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T Ferreira da Silva, Tiago Galan-Arriola, Carlos Montesinos, Paula López-Martín, Gonzalo Javier Desco, Manuel Fuster, Valentín Ibáñez, Borja Sanchez-Gonzalez, Javier MAGMA Research Article OBJECTIVES: To propose and validate a novel imaging sequence that uses a single breath-hold whole-heart 3D T1 saturation recovery compressed SENSE rapid acquisition (SACORA) at 3T. METHODS: The proposed sequence combines flexible saturation time sampling, compressed SENSE, and sharing of saturation pulses between two readouts acquired at different RR intervals. The sequence was compared with a 3D saturation recovery single-shot acquisition (SASHA) implementation with phantom and in vivo experiments (pre and post contrast; 7 pigs) and was validated against the reference inversion recovery spin echo (IR-SE) sequence in phantom experiments. RESULTS: Phantom experiments showed that the T1 maps acquired by 3D SACORA and 3D SASHA agree well with IR-SE. In vivo experiments showed that the pre-contrast and post-contrast T1 maps acquired by 3D SACORA are comparable to the corresponding 3D SASHA maps, despite the shorter acquisition time (15s vs. 188s, for a heart rate of 60 bpm). Mean septal pre-contrast T1 was 1453 ± 44 ms with 3D SACORA and 1460 ± 60 ms with 3D SASHA. Mean septal post-contrast T1 was 824 ± 66 ms and 824 ± 60 ms. CONCLUSION: 3D SACORA acquires 3D T1 maps in 15 heart beats (heart rate, 60 bpm) at 3T. In addition to its short acquisition time, the sequence achieves good T1 estimation precision and accuracy. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10334-020-00848-2) contains supplementary material, which is available to authorized users. Springer International Publishing 2020-05-14 2020 /pmc/articles/PMC7669807/ /pubmed/32410103 http://dx.doi.org/10.1007/s10334-020-00848-2 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Research Article
Ferreira da Silva, Tiago
Galan-Arriola, Carlos
Montesinos, Paula
López-Martín, Gonzalo Javier
Desco, Manuel
Fuster, Valentín
Ibáñez, Borja
Sanchez-Gonzalez, Javier
Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
title Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
title_full Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
title_fullStr Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
title_full_unstemmed Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
title_short Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
title_sort single breath-hold saturation recovery 3d cardiac t1 mapping via compressed sense at 3t
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669807/
https://www.ncbi.nlm.nih.gov/pubmed/32410103
http://dx.doi.org/10.1007/s10334-020-00848-2
work_keys_str_mv AT ferreiradasilvatiago singlebreathholdsaturationrecovery3dcardiact1mappingviacompressedsenseat3t
AT galanarriolacarlos singlebreathholdsaturationrecovery3dcardiact1mappingviacompressedsenseat3t
AT montesinospaula singlebreathholdsaturationrecovery3dcardiact1mappingviacompressedsenseat3t
AT lopezmartingonzalojavier singlebreathholdsaturationrecovery3dcardiact1mappingviacompressedsenseat3t
AT descomanuel singlebreathholdsaturationrecovery3dcardiact1mappingviacompressedsenseat3t
AT fustervalentin singlebreathholdsaturationrecovery3dcardiact1mappingviacompressedsenseat3t
AT ibanezborja singlebreathholdsaturationrecovery3dcardiact1mappingviacompressedsenseat3t
AT sanchezgonzalezjavier singlebreathholdsaturationrecovery3dcardiact1mappingviacompressedsenseat3t