Cargando…

The photopic negative response (PhNR): measurement approaches and utility in glaucoma

PURPOSE: Visual electrophysiological testing continues to generate interest among glaucoma experts because of its potential help in clarifying disease pathophysiology and promoting early detection of glaucomatous damage. The photopic negative response (PhNR) is a slow negative component of the full-...

Descripción completa

Detalles Bibliográficos
Autores principales: Prencipe, Matteo, Perossini, Tommaso, Brancoli, Giampaolo, Perossini, Mario
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669808/
https://www.ncbi.nlm.nih.gov/pubmed/32737731
http://dx.doi.org/10.1007/s10792-020-01515-0
_version_ 1783610612879720448
author Prencipe, Matteo
Perossini, Tommaso
Brancoli, Giampaolo
Perossini, Mario
author_facet Prencipe, Matteo
Perossini, Tommaso
Brancoli, Giampaolo
Perossini, Mario
author_sort Prencipe, Matteo
collection PubMed
description PURPOSE: Visual electrophysiological testing continues to generate interest among glaucoma experts because of its potential help in clarifying disease pathophysiology and promoting early detection of glaucomatous damage. The photopic negative response (PhNR) is a slow negative component of the full-field electroretinogram that has been shown to provide specific information about retinal ganglion cells (RGCs) activity. The purpose of this article is to review the literature to explore the currently available measurement methods and the utility of PhNR in glaucoma diagnostic process. METHODS: We gathered publications related to the origins, types of stimuli used, measurements methods and applications of the PhNR of ERG in animal models and humans through a search of the literature cited in PubMed. Search terms were: “PhNR”, “photopic negative response”, “glaucoma”, “glaucomatous optic neuropathy”, “ERG”, “electroretinogram”. RESULTS: The most reliable PhNR measurements are obtained using a red stimulus on a blue background, without requiring refractive correction, fixation monitoring, or ocular media transparency. Given its direct correlation with RGCs response, the PhNR measured as baseline-to-trough (BT) represents the most reliable parameter of evaluation. Glaucoma patients with evident perimetric defects show pathologic PhNR values. Even though the PhNR is promising in detecting early RGCs impairment, distinguishing between healthy subjects and suspect patients at risk of developing glaucomatous damage still remains challenging. CONCLUSION: The PhNR is a useful additional tool to explore disorders that affect the innermost retina, including glaucoma and other forms of optic neuropathy. In particular, comparing reports of the standard examinations (optic disc assessment, OCT RNFL measurement, standard automated perimetry) with the results of electrophysiological tests may be helpful in solving clinical diagnostic and management dilemmas. On the one hand, the PhNR of the ERG can examine the parvocellular pathways; on the other hand, the steady-state pattern ERG optimized for glaucoma screening (PERGLA) can explore the magnocellular pathways. This could give ophthalmologists a useful feedback to identify early RGCs alterations suggestive of glaucoma, stratify the risk and potentially monitor disease progression.
format Online
Article
Text
id pubmed-7669808
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-76698082020-11-17 The photopic negative response (PhNR): measurement approaches and utility in glaucoma Prencipe, Matteo Perossini, Tommaso Brancoli, Giampaolo Perossini, Mario Int Ophthalmol Review PURPOSE: Visual electrophysiological testing continues to generate interest among glaucoma experts because of its potential help in clarifying disease pathophysiology and promoting early detection of glaucomatous damage. The photopic negative response (PhNR) is a slow negative component of the full-field electroretinogram that has been shown to provide specific information about retinal ganglion cells (RGCs) activity. The purpose of this article is to review the literature to explore the currently available measurement methods and the utility of PhNR in glaucoma diagnostic process. METHODS: We gathered publications related to the origins, types of stimuli used, measurements methods and applications of the PhNR of ERG in animal models and humans through a search of the literature cited in PubMed. Search terms were: “PhNR”, “photopic negative response”, “glaucoma”, “glaucomatous optic neuropathy”, “ERG”, “electroretinogram”. RESULTS: The most reliable PhNR measurements are obtained using a red stimulus on a blue background, without requiring refractive correction, fixation monitoring, or ocular media transparency. Given its direct correlation with RGCs response, the PhNR measured as baseline-to-trough (BT) represents the most reliable parameter of evaluation. Glaucoma patients with evident perimetric defects show pathologic PhNR values. Even though the PhNR is promising in detecting early RGCs impairment, distinguishing between healthy subjects and suspect patients at risk of developing glaucomatous damage still remains challenging. CONCLUSION: The PhNR is a useful additional tool to explore disorders that affect the innermost retina, including glaucoma and other forms of optic neuropathy. In particular, comparing reports of the standard examinations (optic disc assessment, OCT RNFL measurement, standard automated perimetry) with the results of electrophysiological tests may be helpful in solving clinical diagnostic and management dilemmas. On the one hand, the PhNR of the ERG can examine the parvocellular pathways; on the other hand, the steady-state pattern ERG optimized for glaucoma screening (PERGLA) can explore the magnocellular pathways. This could give ophthalmologists a useful feedback to identify early RGCs alterations suggestive of glaucoma, stratify the risk and potentially monitor disease progression. Springer Netherlands 2020-07-31 2020 /pmc/articles/PMC7669808/ /pubmed/32737731 http://dx.doi.org/10.1007/s10792-020-01515-0 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Review
Prencipe, Matteo
Perossini, Tommaso
Brancoli, Giampaolo
Perossini, Mario
The photopic negative response (PhNR): measurement approaches and utility in glaucoma
title The photopic negative response (PhNR): measurement approaches and utility in glaucoma
title_full The photopic negative response (PhNR): measurement approaches and utility in glaucoma
title_fullStr The photopic negative response (PhNR): measurement approaches and utility in glaucoma
title_full_unstemmed The photopic negative response (PhNR): measurement approaches and utility in glaucoma
title_short The photopic negative response (PhNR): measurement approaches and utility in glaucoma
title_sort photopic negative response (phnr): measurement approaches and utility in glaucoma
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7669808/
https://www.ncbi.nlm.nih.gov/pubmed/32737731
http://dx.doi.org/10.1007/s10792-020-01515-0
work_keys_str_mv AT prencipematteo thephotopicnegativeresponsephnrmeasurementapproachesandutilityinglaucoma
AT perossinitommaso thephotopicnegativeresponsephnrmeasurementapproachesandutilityinglaucoma
AT brancoligiampaolo thephotopicnegativeresponsephnrmeasurementapproachesandutilityinglaucoma
AT perossinimario thephotopicnegativeresponsephnrmeasurementapproachesandutilityinglaucoma
AT prencipematteo photopicnegativeresponsephnrmeasurementapproachesandutilityinglaucoma
AT perossinitommaso photopicnegativeresponsephnrmeasurementapproachesandutilityinglaucoma
AT brancoligiampaolo photopicnegativeresponsephnrmeasurementapproachesandutilityinglaucoma
AT perossinimario photopicnegativeresponsephnrmeasurementapproachesandutilityinglaucoma