Cargando…

Unconventional combination of left atrial appendage device occlusion in patients with atrial fibrillation who needed concomitant catheter interventions for underlying structural heart disease

OBJECTIVES: Left atrial appendage occlusion (LAAO) in non-valvar atrial fibrillation (AF) reduces cardioembolic strokes. Despite increased risk, trials exclude valvar AF in structural heart diseases where clots extend beyond appendage. METHODS: Patients with AF and relative risks for oral anticoagul...

Descripción completa

Detalles Bibliográficos
Autores principales: Raghuram, Palaparti, Pavithran, Sreeja, Sivakumar, Kothandam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7670275/
https://www.ncbi.nlm.nih.gov/pubmed/33189196
http://dx.doi.org/10.1016/j.ihj.2020.07.019
Descripción
Sumario:OBJECTIVES: Left atrial appendage occlusion (LAAO) in non-valvar atrial fibrillation (AF) reduces cardioembolic strokes. Despite increased risk, trials exclude valvar AF in structural heart diseases where clots extend beyond appendage. METHODS: Patients with AF and relative risks for oral anticoagulation (OAC) needing structural interventions underwent concomitant LAAO. After six months of OAC, aspirin was continued. Transesophageal echocardiogram was done three monthly till one year and yearly thereafter. The patient demographics, procedural details, post-procedural follow-up were analyzed. RESULTS: Nine patients aged 51.5 ± 6.3 years with AF underwent LAAO concomitantly with balloon mitral valvotomy in four patients, atrial septal defect device closure in four and periprosthetic mitral leak closure in one patient. Six patients had heart failure, four had prior embolic events, and two had documented LAA thrombus. The mean CHADS(2)VASc score was 2.44 ± 0.8 and mean HASBLED score was 3.0 ± 0.8. Devices included Amplatzer Cardiac Plug™ in six patients, LAmbre™ Lifetech device in two and Watchman™ device in one. All procedures were successful without acute complications. A patient developed pericardial effusion at six months requiring pericardiocentesis. Early device-associated thrombus in one patient resolved after OAC for six months. No embolic events occurred on follow-up. CONCLUSION: On a detailed literature search, this largest LAAO experience in structural heart diseases indicates its utility. OAC for six months followed by aspirin seems to prevent thrombus formation in these patients. The only incidence of early thrombus formation indicates immunity from clot formation after device endothelialisation. Larger multicenter trials combining LAAO with structural interventions in valvular AF are warranted in developing nations.