Cargando…
Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres
A simple and reliable HPLC method was developed and validated for determination of rofecoxib in bovine serum albumin microsphere. The analyses were performed on a C18 column (150 x 4.6 mm, 5 μm particle size) at room temperature with UV detection at 272 nm. The mobile phase was composed of acetonitr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Scientific and Technological Research Council of Turkey
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671206/ https://www.ncbi.nlm.nih.gov/pubmed/33488183 http://dx.doi.org/10.3906/kim-1912-45 |
_version_ | 1783610884457758720 |
---|---|
author | DEMİRTÜRK, Esra NEMUTLU, Emirhan ŞAHİN, Selma ÖNER, Levent |
author_facet | DEMİRTÜRK, Esra NEMUTLU, Emirhan ŞAHİN, Selma ÖNER, Levent |
author_sort | DEMİRTÜRK, Esra |
collection | PubMed |
description | A simple and reliable HPLC method was developed and validated for determination of rofecoxib in bovine serum albumin microsphere. The analyses were performed on a C18 column (150 x 4.6 mm, 5 μm particle size) at room temperature with UV detection at 272 nm. The mobile phase was composed of acetonitrile-0.1% o-phosphoric acid solution in water (1:1, v/v) mixture, and flow rate was set to 1 mL/min. The method was validated according to the international guidelines with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity, and robustness. The detection and quantification limit of the method were 1.0 μg/mL and 2.5 μg/mL, respectively. The method was linear in the range of 2.5–25 μg/mL with excellent determination coefficients (R2 >0.99). Intra-day and inter-day precision (<1.76% RSD) and accuracy (<0.55 % Bias) values of the method also fulfilled the required limits. It was concluded that the developed method was accurate, sensitive, precise, and reproducible according to the evaluation of the validation parameters. The applicability of the method was confirmed for in vitro quantification of rofecoxib in bovine serum albumin microspheres. |
format | Online Article Text |
id | pubmed-7671206 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Scientific and Technological Research Council of Turkey |
record_format | MEDLINE/PubMed |
spelling | pubmed-76712062021-01-22 Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres DEMİRTÜRK, Esra NEMUTLU, Emirhan ŞAHİN, Selma ÖNER, Levent Turk J Chem Article A simple and reliable HPLC method was developed and validated for determination of rofecoxib in bovine serum albumin microsphere. The analyses were performed on a C18 column (150 x 4.6 mm, 5 μm particle size) at room temperature with UV detection at 272 nm. The mobile phase was composed of acetonitrile-0.1% o-phosphoric acid solution in water (1:1, v/v) mixture, and flow rate was set to 1 mL/min. The method was validated according to the international guidelines with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity, and robustness. The detection and quantification limit of the method were 1.0 μg/mL and 2.5 μg/mL, respectively. The method was linear in the range of 2.5–25 μg/mL with excellent determination coefficients (R2 >0.99). Intra-day and inter-day precision (<1.76% RSD) and accuracy (<0.55 % Bias) values of the method also fulfilled the required limits. It was concluded that the developed method was accurate, sensitive, precise, and reproducible according to the evaluation of the validation parameters. The applicability of the method was confirmed for in vitro quantification of rofecoxib in bovine serum albumin microspheres. The Scientific and Technological Research Council of Turkey 2020-06-01 /pmc/articles/PMC7671206/ /pubmed/33488183 http://dx.doi.org/10.3906/kim-1912-45 Text en Copyright © 2020 The Author(s) This article is distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0/ ), which permits unrestricted use and redistribution provided that the original author and source are credited. |
spellingShingle | Article DEMİRTÜRK, Esra NEMUTLU, Emirhan ŞAHİN, Selma ÖNER, Levent Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres |
title | Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres |
title_full | Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres |
title_fullStr | Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres |
title_full_unstemmed | Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres |
title_short | Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres |
title_sort | development and validation of an hplc method for determination of rofecoxib in bovine serum albumin microspheres |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671206/ https://www.ncbi.nlm.nih.gov/pubmed/33488183 http://dx.doi.org/10.3906/kim-1912-45 |
work_keys_str_mv | AT demirturkesra developmentandvalidationofanhplcmethodfordeterminationofrofecoxibinbovineserumalbuminmicrospheres AT nemutluemirhan developmentandvalidationofanhplcmethodfordeterminationofrofecoxibinbovineserumalbuminmicrospheres AT sahinselma developmentandvalidationofanhplcmethodfordeterminationofrofecoxibinbovineserumalbuminmicrospheres AT onerlevent developmentandvalidationofanhplcmethodfordeterminationofrofecoxibinbovineserumalbuminmicrospheres |