Cargando…

Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres

A simple and reliable HPLC method was developed and validated for determination of rofecoxib in bovine serum albumin microsphere. The analyses were performed on a C18 column (150 x 4.6 mm, 5 μm particle size) at room temperature with UV detection at 272 nm. The mobile phase was composed of acetonitr...

Descripción completa

Detalles Bibliográficos
Autores principales: DEMİRTÜRK, Esra, NEMUTLU, Emirhan, ŞAHİN, Selma, ÖNER, Levent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Scientific and Technological Research Council of Turkey 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671206/
https://www.ncbi.nlm.nih.gov/pubmed/33488183
http://dx.doi.org/10.3906/kim-1912-45
_version_ 1783610884457758720
author DEMİRTÜRK, Esra
NEMUTLU, Emirhan
ŞAHİN, Selma
ÖNER, Levent
author_facet DEMİRTÜRK, Esra
NEMUTLU, Emirhan
ŞAHİN, Selma
ÖNER, Levent
author_sort DEMİRTÜRK, Esra
collection PubMed
description A simple and reliable HPLC method was developed and validated for determination of rofecoxib in bovine serum albumin microsphere. The analyses were performed on a C18 column (150 x 4.6 mm, 5 μm particle size) at room temperature with UV detection at 272 nm. The mobile phase was composed of acetonitrile-0.1% o-phosphoric acid solution in water (1:1, v/v) mixture, and flow rate was set to 1 mL/min. The method was validated according to the international guidelines with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity, and robustness. The detection and quantification limit of the method were 1.0 μg/mL and 2.5 μg/mL, respectively. The method was linear in the range of 2.5–25 μg/mL with excellent determination coefficients (R2 >0.99). Intra-day and inter-day precision (<1.76% RSD) and accuracy (<0.55 % Bias) values of the method also fulfilled the required limits. It was concluded that the developed method was accurate, sensitive, precise, and reproducible according to the evaluation of the validation parameters. The applicability of the method was confirmed for in vitro quantification of rofecoxib in bovine serum albumin microspheres.
format Online
Article
Text
id pubmed-7671206
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Scientific and Technological Research Council of Turkey
record_format MEDLINE/PubMed
spelling pubmed-76712062021-01-22 Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres DEMİRTÜRK, Esra NEMUTLU, Emirhan ŞAHİN, Selma ÖNER, Levent Turk J Chem Article A simple and reliable HPLC method was developed and validated for determination of rofecoxib in bovine serum albumin microsphere. The analyses were performed on a C18 column (150 x 4.6 mm, 5 μm particle size) at room temperature with UV detection at 272 nm. The mobile phase was composed of acetonitrile-0.1% o-phosphoric acid solution in water (1:1, v/v) mixture, and flow rate was set to 1 mL/min. The method was validated according to the international guidelines with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity, and robustness. The detection and quantification limit of the method were 1.0 μg/mL and 2.5 μg/mL, respectively. The method was linear in the range of 2.5–25 μg/mL with excellent determination coefficients (R2 >0.99). Intra-day and inter-day precision (<1.76% RSD) and accuracy (<0.55 % Bias) values of the method also fulfilled the required limits. It was concluded that the developed method was accurate, sensitive, precise, and reproducible according to the evaluation of the validation parameters. The applicability of the method was confirmed for in vitro quantification of rofecoxib in bovine serum albumin microspheres. The Scientific and Technological Research Council of Turkey 2020-06-01 /pmc/articles/PMC7671206/ /pubmed/33488183 http://dx.doi.org/10.3906/kim-1912-45 Text en Copyright © 2020 The Author(s) This article is distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0/ ), which permits unrestricted use and redistribution provided that the original author and source are credited.
spellingShingle Article
DEMİRTÜRK, Esra
NEMUTLU, Emirhan
ŞAHİN, Selma
ÖNER, Levent
Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres
title Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres
title_full Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres
title_fullStr Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres
title_full_unstemmed Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres
title_short Development and validation of an HPLC method for determination of rofecoxib in bovine serum albumin microspheres
title_sort development and validation of an hplc method for determination of rofecoxib in bovine serum albumin microspheres
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671206/
https://www.ncbi.nlm.nih.gov/pubmed/33488183
http://dx.doi.org/10.3906/kim-1912-45
work_keys_str_mv AT demirturkesra developmentandvalidationofanhplcmethodfordeterminationofrofecoxibinbovineserumalbuminmicrospheres
AT nemutluemirhan developmentandvalidationofanhplcmethodfordeterminationofrofecoxibinbovineserumalbuminmicrospheres
AT sahinselma developmentandvalidationofanhplcmethodfordeterminationofrofecoxibinbovineserumalbuminmicrospheres
AT onerlevent developmentandvalidationofanhplcmethodfordeterminationofrofecoxibinbovineserumalbuminmicrospheres