Cargando…
A novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum
An inexpensive, simple, highly sensitive, and rapid fluorimetric method was developed for the analysis of pseudoephedrine hydrochloride at trace levels. The method is based on the recovery of fluorescence of Rh6G dye due to the interaction of pseudoephedrine hydrochloride with Rh6G-Au NPs complex, w...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Scientific and Technological Research Council of Turkey
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671220/ https://www.ncbi.nlm.nih.gov/pubmed/33488184 http://dx.doi.org/10.3906/kim-1912-6 |
_version_ | 1783610887767064576 |
---|---|
author | FARAJZADEH, Nazli RANJBAR NADER, Nasrin |
author_facet | FARAJZADEH, Nazli RANJBAR NADER, Nasrin |
author_sort | FARAJZADEH, Nazli |
collection | PubMed |
description | An inexpensive, simple, highly sensitive, and rapid fluorimetric method was developed for the analysis of pseudoephedrine hydrochloride at trace levels. The method is based on the recovery of fluorescence of Rh6G dye due to the interaction of pseudoephedrine hydrochloride with Rh6G-Au NPs complex, which results in the release of Rh6G from the complex and halting fluorescence resonance energy transfer between Rh6G and Au NPs. The intensity of fluorescence was directly proportional to the concentration of the analyte, which was used for its determination. Experimental factors were optimized by response-surface methodology. Under optimum conditions, the calibration curve was linear over the range of 15–150 ng mL(-1) and the limit of detection (LOD) was 10 ng mL(-1). Percent relative standard deviation (n= 5) for determination of 50 ng mL(-1) pseudoephedrine hydrochloride was 3.74%. The method was successfully used for determining the analyte in human blood serum and in pharmaceutical formulations. The possible mechanistic description of the analytical reaction was proposed on the basis of TEM, FT-IR, and fluorescence spectra analysis. |
format | Online Article Text |
id | pubmed-7671220 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Scientific and Technological Research Council of Turkey |
record_format | MEDLINE/PubMed |
spelling | pubmed-76712202021-01-22 A novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum FARAJZADEH, Nazli RANJBAR NADER, Nasrin Turk J Chem Article An inexpensive, simple, highly sensitive, and rapid fluorimetric method was developed for the analysis of pseudoephedrine hydrochloride at trace levels. The method is based on the recovery of fluorescence of Rh6G dye due to the interaction of pseudoephedrine hydrochloride with Rh6G-Au NPs complex, which results in the release of Rh6G from the complex and halting fluorescence resonance energy transfer between Rh6G and Au NPs. The intensity of fluorescence was directly proportional to the concentration of the analyte, which was used for its determination. Experimental factors were optimized by response-surface methodology. Under optimum conditions, the calibration curve was linear over the range of 15–150 ng mL(-1) and the limit of detection (LOD) was 10 ng mL(-1). Percent relative standard deviation (n= 5) for determination of 50 ng mL(-1) pseudoephedrine hydrochloride was 3.74%. The method was successfully used for determining the analyte in human blood serum and in pharmaceutical formulations. The possible mechanistic description of the analytical reaction was proposed on the basis of TEM, FT-IR, and fluorescence spectra analysis. The Scientific and Technological Research Council of Turkey 2020-06-01 /pmc/articles/PMC7671220/ /pubmed/33488184 http://dx.doi.org/10.3906/kim-1912-6 Text en Copyright © 2020 The Author(s) This article is distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0/ ), which permits unrestricted use and redistribution provided that the original author and source are credited. |
spellingShingle | Article FARAJZADEH, Nazli RANJBAR NADER, Nasrin A novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum |
title | A novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum |
title_full | A novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum |
title_fullStr | A novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum |
title_full_unstemmed | A novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum |
title_short | A novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum |
title_sort | novel fluorimetric method for determination of pseudoephedrine hydrochloride in pharmaceutical formulations and blood serum |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671220/ https://www.ncbi.nlm.nih.gov/pubmed/33488184 http://dx.doi.org/10.3906/kim-1912-6 |
work_keys_str_mv | AT farajzadehnazli anovelfluorimetricmethodfordeterminationofpseudoephedrinehydrochlorideinpharmaceuticalformulationsandbloodserum AT ranjbarnadernasrin anovelfluorimetricmethodfordeterminationofpseudoephedrinehydrochlorideinpharmaceuticalformulationsandbloodserum AT farajzadehnazli novelfluorimetricmethodfordeterminationofpseudoephedrinehydrochlorideinpharmaceuticalformulationsandbloodserum AT ranjbarnadernasrin novelfluorimetricmethodfordeterminationofpseudoephedrinehydrochlorideinpharmaceuticalformulationsandbloodserum |