Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants
BACKGROUND: Although silicone breast implants have been available for over 60 years, their safety and efficacy continue to be assessed via long-term clinical and vigilance studies. Complications often associated with breast implant surgery include but are not limited to capsular contracture and rupt...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671289/ https://www.ncbi.nlm.nih.gov/pubmed/33791608 http://dx.doi.org/10.1093/asjof/ojz012 |
Sumario: | BACKGROUND: Although silicone breast implants have been available for over 60 years, their safety and efficacy continue to be assessed via long-term clinical and vigilance studies. Complications often associated with breast implant surgery include but are not limited to capsular contracture and rupture. OBJECTIVE: The authors investigate and evaluate the safety and performance of Eurosilicone’s (Eurosilicone S.A.S, Apt Cedex, France) Cristalline Paragel breast implants at least 10 years postimplantation. METHODS: Nine hundred and ninety-five of Eurosilicone’s textured mammary implants were implanted in 526 women undergoing primary (423 patients) and revision surgery (103 patients) at 17 centers throughout France. Complications were recorded at 3 months and annually thereafter for 10 years. Descriptive statistics were used and the Kaplan-Meier method was utilized to analyze key complications. RESULTS: Seventy-four women (98 implants) experienced capsular contracture across all cohorts. The Kaplan-Meier 10-year cumulative risk of capsular contracture (Baker Grade III/IV) per implant was 11.5% in the primary augmentation cohort and 25.2% in the primary reconstruction cohort. Sixteen implant ruptures were observed by surgeon examination giving a Kaplan-Meier risk of 3.8% per patient and 3.5% per implant. Surgical re-intervention (explantation/exchange) was reported 80 times resulting in a Kaplan-Meier cumulative risk of 13.3% and 31.6% for primary augmentation and primary reconstruction, respectively, per patient. Local complication rates including infection and seroma were low with risk rates of 0.6% and 0.2% by subject. CONCLUSIONS: This multicenter clinical study demonstrates the long-term safety and efficacy profile through 10 years for Eurosilicone round and anatomical silicone gel breast implants. LEVEL OF EVIDENCE: 3: [Image: see text] |
---|