Cargando…

Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants

BACKGROUND: Although silicone breast implants have been available for over 60 years, their safety and efficacy continue to be assessed via long-term clinical and vigilance studies. Complications often associated with breast implant surgery include but are not limited to capsular contracture and rupt...

Descripción completa

Detalles Bibliográficos
Autores principales: Duteille, Franck, Perrot, Pierre, Bacheley, Marie-Hélène, Bell, Erin, Stewart, Sharon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671289/
https://www.ncbi.nlm.nih.gov/pubmed/33791608
http://dx.doi.org/10.1093/asjof/ojz012
_version_ 1783610901206663168
author Duteille, Franck
Perrot, Pierre
Bacheley, Marie-Hélène
Bell, Erin
Stewart, Sharon
author_facet Duteille, Franck
Perrot, Pierre
Bacheley, Marie-Hélène
Bell, Erin
Stewart, Sharon
author_sort Duteille, Franck
collection PubMed
description BACKGROUND: Although silicone breast implants have been available for over 60 years, their safety and efficacy continue to be assessed via long-term clinical and vigilance studies. Complications often associated with breast implant surgery include but are not limited to capsular contracture and rupture. OBJECTIVE: The authors investigate and evaluate the safety and performance of Eurosilicone’s (Eurosilicone S.A.S, Apt Cedex, France) Cristalline Paragel breast implants at least 10 years postimplantation. METHODS: Nine hundred and ninety-five of Eurosilicone’s textured mammary implants were implanted in 526 women undergoing primary (423 patients) and revision surgery (103 patients) at 17 centers throughout France. Complications were recorded at 3 months and annually thereafter for 10 years. Descriptive statistics were used and the Kaplan-Meier method was utilized to analyze key complications. RESULTS: Seventy-four women (98 implants) experienced capsular contracture across all cohorts. The Kaplan-Meier 10-year cumulative risk of capsular contracture (Baker Grade III/IV) per implant was 11.5% in the primary augmentation cohort and 25.2% in the primary reconstruction cohort. Sixteen implant ruptures were observed by surgeon examination giving a Kaplan-Meier risk of 3.8% per patient and 3.5% per implant. Surgical re-intervention (explantation/exchange) was reported 80 times resulting in a Kaplan-Meier cumulative risk of 13.3% and 31.6% for primary augmentation and primary reconstruction, respectively, per patient. Local complication rates including infection and seroma were low with risk rates of 0.6% and 0.2% by subject. CONCLUSIONS: This multicenter clinical study demonstrates the long-term safety and efficacy profile through 10 years for Eurosilicone round and anatomical silicone gel breast implants. LEVEL OF EVIDENCE: 3: [Image: see text]
format Online
Article
Text
id pubmed-7671289
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-76712892021-03-30 Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants Duteille, Franck Perrot, Pierre Bacheley, Marie-Hélène Bell, Erin Stewart, Sharon Aesthet Surg J Open Forum Original Article BACKGROUND: Although silicone breast implants have been available for over 60 years, their safety and efficacy continue to be assessed via long-term clinical and vigilance studies. Complications often associated with breast implant surgery include but are not limited to capsular contracture and rupture. OBJECTIVE: The authors investigate and evaluate the safety and performance of Eurosilicone’s (Eurosilicone S.A.S, Apt Cedex, France) Cristalline Paragel breast implants at least 10 years postimplantation. METHODS: Nine hundred and ninety-five of Eurosilicone’s textured mammary implants were implanted in 526 women undergoing primary (423 patients) and revision surgery (103 patients) at 17 centers throughout France. Complications were recorded at 3 months and annually thereafter for 10 years. Descriptive statistics were used and the Kaplan-Meier method was utilized to analyze key complications. RESULTS: Seventy-four women (98 implants) experienced capsular contracture across all cohorts. The Kaplan-Meier 10-year cumulative risk of capsular contracture (Baker Grade III/IV) per implant was 11.5% in the primary augmentation cohort and 25.2% in the primary reconstruction cohort. Sixteen implant ruptures were observed by surgeon examination giving a Kaplan-Meier risk of 3.8% per patient and 3.5% per implant. Surgical re-intervention (explantation/exchange) was reported 80 times resulting in a Kaplan-Meier cumulative risk of 13.3% and 31.6% for primary augmentation and primary reconstruction, respectively, per patient. Local complication rates including infection and seroma were low with risk rates of 0.6% and 0.2% by subject. CONCLUSIONS: This multicenter clinical study demonstrates the long-term safety and efficacy profile through 10 years for Eurosilicone round and anatomical silicone gel breast implants. LEVEL OF EVIDENCE: 3: [Image: see text] Oxford University Press 2019-04-27 /pmc/articles/PMC7671289/ /pubmed/33791608 http://dx.doi.org/10.1093/asjof/ojz012 Text en © 2019 The American Society for Aesthetic Plastic Surgery, Inc. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Duteille, Franck
Perrot, Pierre
Bacheley, Marie-Hélène
Bell, Erin
Stewart, Sharon
Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants
title Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants
title_full Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants
title_fullStr Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants
title_full_unstemmed Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants
title_short Ten-Year Safety Data for Eurosilicone’s Round and Anatomical Silicone Gel Breast Implants
title_sort ten-year safety data for eurosilicone’s round and anatomical silicone gel breast implants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671289/
https://www.ncbi.nlm.nih.gov/pubmed/33791608
http://dx.doi.org/10.1093/asjof/ojz012
work_keys_str_mv AT duteillefranck tenyearsafetydataforeurosiliconesroundandanatomicalsiliconegelbreastimplants
AT perrotpierre tenyearsafetydataforeurosiliconesroundandanatomicalsiliconegelbreastimplants
AT bacheleymariehelene tenyearsafetydataforeurosiliconesroundandanatomicalsiliconegelbreastimplants
AT bellerin tenyearsafetydataforeurosiliconesroundandanatomicalsiliconegelbreastimplants
AT stewartsharon tenyearsafetydataforeurosiliconesroundandanatomicalsiliconegelbreastimplants