Cargando…

In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness

Interim crowns and partial fixed dental prosthesis materials generate exothermic heat during polymerization. The amount of heat transmitted to the pulp chamber can be a function of several factors, including the thickness and quality of the remaining dentin after crown preparation. The aim of this i...

Descripción completa

Detalles Bibliográficos
Autores principales: Lipski, Mariusz, Woźniak, Krzysztof, Szyszka-Sommerfeld, Liliana, Borawski, Mariusz, Droździk, Agnieszka, Nowicka, Alicja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671814/
https://www.ncbi.nlm.nih.gov/pubmed/33224457
http://dx.doi.org/10.1155/2020/8838329
_version_ 1783611001415925760
author Lipski, Mariusz
Woźniak, Krzysztof
Szyszka-Sommerfeld, Liliana
Borawski, Mariusz
Droździk, Agnieszka
Nowicka, Alicja
author_facet Lipski, Mariusz
Woźniak, Krzysztof
Szyszka-Sommerfeld, Liliana
Borawski, Mariusz
Droździk, Agnieszka
Nowicka, Alicja
author_sort Lipski, Mariusz
collection PubMed
description Interim crowns and partial fixed dental prosthesis materials generate exothermic heat during polymerization. The amount of heat transmitted to the pulp chamber can be a function of several factors, including the thickness and quality of the remaining dentin after crown preparation. The aim of this in vitro study was to measure with infrared thermography the temperature changes on the adjacent surface of the chamber roof of premolar teeth extracted from young and old patients (having different thicknesses of remaining dentin after crown preparation) during fabrication of provisional resinous restorations. Twenty extracted human first and second maxillary premolar teeth (10 from young patients, with a relatively large pulp chamber, and 10 from older patients, with a relatively small pulp chamber) were used. The roots were sectioned to expose the inner side of the chamber roof, and the crowns were provisionalized after preparation for a metal-ceramic crown. Two provisional materials, Turbo Temp 2 and Luxatemp Fluorescence, were used. Temperature changes on the inner side of the chamber roof were measured at 2-second intervals using an infrared thermal imaging camera. After completion of the temperature recordings, the teeth were sectioned and the remaining dentin thickness was determined. The older group (mean thickness: 2.82 mm) and younger group (mean thickness: 1.9 mm) differed significantly in dentin thickness (P < 0.014). The mean greatest temperature increases recorded on the chamber roof of teeth with less remaining dentin were 4.07°C for Turbo Temp 2 and 3.94°C for Luxatemp Fluorescence, while increases in the premolars with greater dentin thickness were 1.69°C for Turbo Temp 2 and 1.64°C for Luxatemp Fluorescence. Significant interactions were found between tooth groups (P < 0.000001for Turbo Temp 2 and for Luxatemp Fluorescence). No significant differences were found between assessed materials regardless of the thickness of the remaining dentin (P > 0.38for the older group and P > 0.29 for the younger group). Dentin had a significant effect in limiting the temperature increase generated during polymerization of provisional materials, indicating good thermal insulating properties of this tissue. A remaining dentin thickness of 1.9 mm or more is sufficient to protect the pulp from any temperature increase during provisionalization using tested materials.
format Online
Article
Text
id pubmed-7671814
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-76718142020-11-19 In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness Lipski, Mariusz Woźniak, Krzysztof Szyszka-Sommerfeld, Liliana Borawski, Mariusz Droździk, Agnieszka Nowicka, Alicja J Healthc Eng Research Article Interim crowns and partial fixed dental prosthesis materials generate exothermic heat during polymerization. The amount of heat transmitted to the pulp chamber can be a function of several factors, including the thickness and quality of the remaining dentin after crown preparation. The aim of this in vitro study was to measure with infrared thermography the temperature changes on the adjacent surface of the chamber roof of premolar teeth extracted from young and old patients (having different thicknesses of remaining dentin after crown preparation) during fabrication of provisional resinous restorations. Twenty extracted human first and second maxillary premolar teeth (10 from young patients, with a relatively large pulp chamber, and 10 from older patients, with a relatively small pulp chamber) were used. The roots were sectioned to expose the inner side of the chamber roof, and the crowns were provisionalized after preparation for a metal-ceramic crown. Two provisional materials, Turbo Temp 2 and Luxatemp Fluorescence, were used. Temperature changes on the inner side of the chamber roof were measured at 2-second intervals using an infrared thermal imaging camera. After completion of the temperature recordings, the teeth were sectioned and the remaining dentin thickness was determined. The older group (mean thickness: 2.82 mm) and younger group (mean thickness: 1.9 mm) differed significantly in dentin thickness (P < 0.014). The mean greatest temperature increases recorded on the chamber roof of teeth with less remaining dentin were 4.07°C for Turbo Temp 2 and 3.94°C for Luxatemp Fluorescence, while increases in the premolars with greater dentin thickness were 1.69°C for Turbo Temp 2 and 1.64°C for Luxatemp Fluorescence. Significant interactions were found between tooth groups (P < 0.000001for Turbo Temp 2 and for Luxatemp Fluorescence). No significant differences were found between assessed materials regardless of the thickness of the remaining dentin (P > 0.38for the older group and P > 0.29 for the younger group). Dentin had a significant effect in limiting the temperature increase generated during polymerization of provisional materials, indicating good thermal insulating properties of this tissue. A remaining dentin thickness of 1.9 mm or more is sufficient to protect the pulp from any temperature increase during provisionalization using tested materials. Hindawi 2020-11-10 /pmc/articles/PMC7671814/ /pubmed/33224457 http://dx.doi.org/10.1155/2020/8838329 Text en Copyright © 2020 Mariusz Lipski et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lipski, Mariusz
Woźniak, Krzysztof
Szyszka-Sommerfeld, Liliana
Borawski, Mariusz
Droździk, Agnieszka
Nowicka, Alicja
In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness
title In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness
title_full In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness
title_fullStr In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness
title_full_unstemmed In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness
title_short In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness
title_sort in vitro infrared thermographic assessment of temperature change in the pulp chamber during provisionalization: effect of remaining dentin thickness
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671814/
https://www.ncbi.nlm.nih.gov/pubmed/33224457
http://dx.doi.org/10.1155/2020/8838329
work_keys_str_mv AT lipskimariusz invitroinfraredthermographicassessmentoftemperaturechangeinthepulpchamberduringprovisionalizationeffectofremainingdentinthickness
AT wozniakkrzysztof invitroinfraredthermographicassessmentoftemperaturechangeinthepulpchamberduringprovisionalizationeffectofremainingdentinthickness
AT szyszkasommerfeldliliana invitroinfraredthermographicassessmentoftemperaturechangeinthepulpchamberduringprovisionalizationeffectofremainingdentinthickness
AT borawskimariusz invitroinfraredthermographicassessmentoftemperaturechangeinthepulpchamberduringprovisionalizationeffectofremainingdentinthickness
AT drozdzikagnieszka invitroinfraredthermographicassessmentoftemperaturechangeinthepulpchamberduringprovisionalizationeffectofremainingdentinthickness
AT nowickaalicja invitroinfraredthermographicassessmentoftemperaturechangeinthepulpchamberduringprovisionalizationeffectofremainingdentinthickness