Too Many Shades of Grey: Photometrically and Spectrally Mismatched Targets and Backgrounds in Printed Acuity Tests for Infants and Young Children
PURPOSE: Acuity tests for infants and young children use preferential looking methods that require a perceptual match of brightness and color between grey background and target spatial average. As a first step in exploring this matching, this article measures photometric and colorimetric matches in...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671855/ https://www.ncbi.nlm.nih.gov/pubmed/33240565 http://dx.doi.org/10.1167/tvst.9.12.12 |
_version_ | 1783611010546925568 |
---|---|
author | Vivas-Mateos, Guillermo Livingstone, Iain A. T. Hamilton, Ruth Cheema, Arsalan Giardini, Mario E. |
author_facet | Vivas-Mateos, Guillermo Livingstone, Iain A. T. Hamilton, Ruth Cheema, Arsalan Giardini, Mario E. |
author_sort | Vivas-Mateos, Guillermo |
collection | PubMed |
description | PURPOSE: Acuity tests for infants and young children use preferential looking methods that require a perceptual match of brightness and color between grey background and target spatial average. As a first step in exploring this matching, this article measures photometric and colorimetric matches in these acuity tests. METHODS: The luminance, uniformity, contrast, and color spectra of Teller Acuity Cards, Keeler Acuity Cards for Infants, and Lea Paddles under ambient, warm, and cold lighting, and of grey-emulating patterns on four digital displays, were measured. Five normal adults’ acuities were tested at 10 m observationally. RESULTS: Luminance and spectral mismatches between target and background were found for the printed tests (Weber contrasts of 0.3% [Teller Acuity Cards], −1.7% [Keeler Acuity Cards for Infants], and −26% [Lea Paddles]). Lighting condition had little effect on contrast, and all printed tests and digital displays met established adult test luminance and uniformity standards. Digital display grey backgrounds had very similar luminance and color whether generated by a checkerboard, vertical grating, or horizontal grating. Improbably good psychophysical acuities (better than −0.300 logMAR: (logarithm of the minimum angle of resolution)) were recorded from adults using the printed tests at 10 m, but not using the digital test Peekaboo Vision. CONCLUSIONS: Perceptible contrast between target and background could lead to an incorrectly measured, excessively good acuity. It is not clear whether the luminance and spectral contrasts described here have clinically meaningful consequences for the target patient group, but they may be avoidable using digital tests. TRANSLATIONAL RELEVANCE: Current clinical infant acuity tests present photometric mismatches that may return inaccurate testing results. |
format | Online Article Text |
id | pubmed-7671855 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-76718552020-11-24 Too Many Shades of Grey: Photometrically and Spectrally Mismatched Targets and Backgrounds in Printed Acuity Tests for Infants and Young Children Vivas-Mateos, Guillermo Livingstone, Iain A. T. Hamilton, Ruth Cheema, Arsalan Giardini, Mario E. Transl Vis Sci Technol Article PURPOSE: Acuity tests for infants and young children use preferential looking methods that require a perceptual match of brightness and color between grey background and target spatial average. As a first step in exploring this matching, this article measures photometric and colorimetric matches in these acuity tests. METHODS: The luminance, uniformity, contrast, and color spectra of Teller Acuity Cards, Keeler Acuity Cards for Infants, and Lea Paddles under ambient, warm, and cold lighting, and of grey-emulating patterns on four digital displays, were measured. Five normal adults’ acuities were tested at 10 m observationally. RESULTS: Luminance and spectral mismatches between target and background were found for the printed tests (Weber contrasts of 0.3% [Teller Acuity Cards], −1.7% [Keeler Acuity Cards for Infants], and −26% [Lea Paddles]). Lighting condition had little effect on contrast, and all printed tests and digital displays met established adult test luminance and uniformity standards. Digital display grey backgrounds had very similar luminance and color whether generated by a checkerboard, vertical grating, or horizontal grating. Improbably good psychophysical acuities (better than −0.300 logMAR: (logarithm of the minimum angle of resolution)) were recorded from adults using the printed tests at 10 m, but not using the digital test Peekaboo Vision. CONCLUSIONS: Perceptible contrast between target and background could lead to an incorrectly measured, excessively good acuity. It is not clear whether the luminance and spectral contrasts described here have clinically meaningful consequences for the target patient group, but they may be avoidable using digital tests. TRANSLATIONAL RELEVANCE: Current clinical infant acuity tests present photometric mismatches that may return inaccurate testing results. The Association for Research in Vision and Ophthalmology 2020-11-06 /pmc/articles/PMC7671855/ /pubmed/33240565 http://dx.doi.org/10.1167/tvst.9.12.12 Text en Copyright 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. |
spellingShingle | Article Vivas-Mateos, Guillermo Livingstone, Iain A. T. Hamilton, Ruth Cheema, Arsalan Giardini, Mario E. Too Many Shades of Grey: Photometrically and Spectrally Mismatched Targets and Backgrounds in Printed Acuity Tests for Infants and Young Children |
title | Too Many Shades of Grey: Photometrically and Spectrally Mismatched Targets and Backgrounds in Printed Acuity Tests for Infants and Young Children |
title_full | Too Many Shades of Grey: Photometrically and Spectrally Mismatched Targets and Backgrounds in Printed Acuity Tests for Infants and Young Children |
title_fullStr | Too Many Shades of Grey: Photometrically and Spectrally Mismatched Targets and Backgrounds in Printed Acuity Tests for Infants and Young Children |
title_full_unstemmed | Too Many Shades of Grey: Photometrically and Spectrally Mismatched Targets and Backgrounds in Printed Acuity Tests for Infants and Young Children |
title_short | Too Many Shades of Grey: Photometrically and Spectrally Mismatched Targets and Backgrounds in Printed Acuity Tests for Infants and Young Children |
title_sort | too many shades of grey: photometrically and spectrally mismatched targets and backgrounds in printed acuity tests for infants and young children |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7671855/ https://www.ncbi.nlm.nih.gov/pubmed/33240565 http://dx.doi.org/10.1167/tvst.9.12.12 |
work_keys_str_mv | AT vivasmateosguillermo toomanyshadesofgreyphotometricallyandspectrallymismatchedtargetsandbackgroundsinprintedacuitytestsforinfantsandyoungchildren AT livingstoneiainat toomanyshadesofgreyphotometricallyandspectrallymismatchedtargetsandbackgroundsinprintedacuitytestsforinfantsandyoungchildren AT hamiltonruth toomanyshadesofgreyphotometricallyandspectrallymismatchedtargetsandbackgroundsinprintedacuitytestsforinfantsandyoungchildren AT cheemaarsalan toomanyshadesofgreyphotometricallyandspectrallymismatchedtargetsandbackgroundsinprintedacuitytestsforinfantsandyoungchildren AT giardinimarioe toomanyshadesofgreyphotometricallyandspectrallymismatchedtargetsandbackgroundsinprintedacuitytestsforinfantsandyoungchildren |