General Practitioner Use of Generically Substitutable Inhaler Devices and the Impact of Training on Device Mastery and Maintenance of Correct Inhaler Technique

INTRODUCTION: Generic substitution of inhaler devices is a relatively new phenomenon. The best patient outcomes associated with generic substitution occur when prescribers obtain consent from their patients to prescribe a generic inhaler and also teach their patient how to correctly use the new devi...

Descripción completa

Detalles Bibliográficos
Autores principales: Cvetkovski, Biljana, Hespe, Charlotte, Tan, Rachel, Kritikos, Vicky, Azzi, Elizabeth, Bosnic-Anticevich, Sinthia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7672138/
https://www.ncbi.nlm.nih.gov/pubmed/33038005
http://dx.doi.org/10.1007/s41030-020-00131-8
_version_ 1783611068133670912
author Cvetkovski, Biljana
Hespe, Charlotte
Tan, Rachel
Kritikos, Vicky
Azzi, Elizabeth
Bosnic-Anticevich, Sinthia
author_facet Cvetkovski, Biljana
Hespe, Charlotte
Tan, Rachel
Kritikos, Vicky
Azzi, Elizabeth
Bosnic-Anticevich, Sinthia
author_sort Cvetkovski, Biljana
collection PubMed
description INTRODUCTION: Generic substitution of inhaler devices is a relatively new phenomenon. The best patient outcomes associated with generic substitution occur when prescribers obtain consent from their patients to prescribe a generic inhaler and also teach their patient how to correctly use the new device. To date, no prospective observational study has assessed the level of training required for general practitioners (GPs) to demonstrate correct inhaler technique using two dry powder inhaler devices delivering fixed-dose combination budesonide/formoterol therapy. This study aims to (1) determine the level of training required for GPs to master and maintain correct IT when using two different dry powder inhalers that are able to be substituted in clinical practice and (2) determine the number and types of errors made by GPs on each device and inhaler device preference at each training visit. METHOD: A randomized, parallel-group cross-over study design was used to compare the inhaler technique of participants with a Spiromax(®) placebo device and a Turbuhaler(®) placebo device. This study consisted of two visits with each participant over a period of 4 ± 1 weeks (visit 1 and visit 2). A total of six levels of assessment and five levels of training were implemented as required. Level 1, no instruction; level 2, following use of written instruction; level 3, following viewing of instructional video; level 4, expert tuition from the researcher; level 5/level 6, repeats of expert tuition from the researcher when required. Participants progressed through each level and stopped at the point at which they demonstrated device mastery. At each level, trained researchers assessed the inhaler technique of the participants. Participants were also surveyed about their previous inhaler use and training. RESULTS: In total, 228 GPs participated in this study by demonstrating their ability to use a Turbuhaler(®) and a Spiromax(®) device. There was no significant difference between the proportion of participants who demonstrated device mastery with the Turbuhaler(®) compared with the Spiromax(®) at level 1, (no instruction), (119/228 (52%) versus 131/228 (57%), respectively, n = 228, p = 0.323 (McNemar’s test of paired data). All but one participant had demonstrated correct inhaler technique for both devices by level 3(instructional video). There was a significant difference between the proportion of participants who demonstrated maintenance of device mastery with the Turbuhaler(®) compared with the Spiromax(®) at visit 2, level 1 (127/177 (72%) versus 151/177 (85%) respectively, p = 0.003; McNemar’s test of paired data). All but two participants achieved device mastery by level 3, visit 2. More participants reported previous training with the Turbuhaler(®) than with Spiromax(®). DISCUSSION: This study demonstrates that GPs are able to equally demonstrate correct use of the Turbuhaler(®) and Spiromax(®) devices, even though most had not received training on a Spiromax(®) device prior to this study. The significance of being able to demonstrate correct technique on these two devices equally has ramifications on practice and supported generic substitution of inhaler devices at the point of prescribing, as the most impactful measure a GP can take to ensure effective use of inhaled medicine is the correct demonstration of inhaler technique. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s41030-020-00131-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7672138
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-76721382020-11-20 General Practitioner Use of Generically Substitutable Inhaler Devices and the Impact of Training on Device Mastery and Maintenance of Correct Inhaler Technique Cvetkovski, Biljana Hespe, Charlotte Tan, Rachel Kritikos, Vicky Azzi, Elizabeth Bosnic-Anticevich, Sinthia Pulm Ther Original Research INTRODUCTION: Generic substitution of inhaler devices is a relatively new phenomenon. The best patient outcomes associated with generic substitution occur when prescribers obtain consent from their patients to prescribe a generic inhaler and also teach their patient how to correctly use the new device. To date, no prospective observational study has assessed the level of training required for general practitioners (GPs) to demonstrate correct inhaler technique using two dry powder inhaler devices delivering fixed-dose combination budesonide/formoterol therapy. This study aims to (1) determine the level of training required for GPs to master and maintain correct IT when using two different dry powder inhalers that are able to be substituted in clinical practice and (2) determine the number and types of errors made by GPs on each device and inhaler device preference at each training visit. METHOD: A randomized, parallel-group cross-over study design was used to compare the inhaler technique of participants with a Spiromax(®) placebo device and a Turbuhaler(®) placebo device. This study consisted of two visits with each participant over a period of 4 ± 1 weeks (visit 1 and visit 2). A total of six levels of assessment and five levels of training were implemented as required. Level 1, no instruction; level 2, following use of written instruction; level 3, following viewing of instructional video; level 4, expert tuition from the researcher; level 5/level 6, repeats of expert tuition from the researcher when required. Participants progressed through each level and stopped at the point at which they demonstrated device mastery. At each level, trained researchers assessed the inhaler technique of the participants. Participants were also surveyed about their previous inhaler use and training. RESULTS: In total, 228 GPs participated in this study by demonstrating their ability to use a Turbuhaler(®) and a Spiromax(®) device. There was no significant difference between the proportion of participants who demonstrated device mastery with the Turbuhaler(®) compared with the Spiromax(®) at level 1, (no instruction), (119/228 (52%) versus 131/228 (57%), respectively, n = 228, p = 0.323 (McNemar’s test of paired data). All but one participant had demonstrated correct inhaler technique for both devices by level 3(instructional video). There was a significant difference between the proportion of participants who demonstrated maintenance of device mastery with the Turbuhaler(®) compared with the Spiromax(®) at visit 2, level 1 (127/177 (72%) versus 151/177 (85%) respectively, p = 0.003; McNemar’s test of paired data). All but two participants achieved device mastery by level 3, visit 2. More participants reported previous training with the Turbuhaler(®) than with Spiromax(®). DISCUSSION: This study demonstrates that GPs are able to equally demonstrate correct use of the Turbuhaler(®) and Spiromax(®) devices, even though most had not received training on a Spiromax(®) device prior to this study. The significance of being able to demonstrate correct technique on these two devices equally has ramifications on practice and supported generic substitution of inhaler devices at the point of prescribing, as the most impactful measure a GP can take to ensure effective use of inhaled medicine is the correct demonstration of inhaler technique. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s41030-020-00131-8) contains supplementary material, which is available to authorized users. Springer Healthcare 2020-10-10 /pmc/articles/PMC7672138/ /pubmed/33038005 http://dx.doi.org/10.1007/s41030-020-00131-8 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Original Research
Cvetkovski, Biljana
Hespe, Charlotte
Tan, Rachel
Kritikos, Vicky
Azzi, Elizabeth
Bosnic-Anticevich, Sinthia
General Practitioner Use of Generically Substitutable Inhaler Devices and the Impact of Training on Device Mastery and Maintenance of Correct Inhaler Technique
title General Practitioner Use of Generically Substitutable Inhaler Devices and the Impact of Training on Device Mastery and Maintenance of Correct Inhaler Technique
title_full General Practitioner Use of Generically Substitutable Inhaler Devices and the Impact of Training on Device Mastery and Maintenance of Correct Inhaler Technique
title_fullStr General Practitioner Use of Generically Substitutable Inhaler Devices and the Impact of Training on Device Mastery and Maintenance of Correct Inhaler Technique
title_full_unstemmed General Practitioner Use of Generically Substitutable Inhaler Devices and the Impact of Training on Device Mastery and Maintenance of Correct Inhaler Technique
title_short General Practitioner Use of Generically Substitutable Inhaler Devices and the Impact of Training on Device Mastery and Maintenance of Correct Inhaler Technique
title_sort general practitioner use of generically substitutable inhaler devices and the impact of training on device mastery and maintenance of correct inhaler technique
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7672138/
https://www.ncbi.nlm.nih.gov/pubmed/33038005
http://dx.doi.org/10.1007/s41030-020-00131-8
work_keys_str_mv AT cvetkovskibiljana generalpractitioneruseofgenericallysubstitutableinhalerdevicesandtheimpactoftrainingondevicemasteryandmaintenanceofcorrectinhalertechnique
AT hespecharlotte generalpractitioneruseofgenericallysubstitutableinhalerdevicesandtheimpactoftrainingondevicemasteryandmaintenanceofcorrectinhalertechnique
AT tanrachel generalpractitioneruseofgenericallysubstitutableinhalerdevicesandtheimpactoftrainingondevicemasteryandmaintenanceofcorrectinhalertechnique
AT kritikosvicky generalpractitioneruseofgenericallysubstitutableinhalerdevicesandtheimpactoftrainingondevicemasteryandmaintenanceofcorrectinhalertechnique
AT azzielizabeth generalpractitioneruseofgenericallysubstitutableinhalerdevicesandtheimpactoftrainingondevicemasteryandmaintenanceofcorrectinhalertechnique
AT bosnicanticevichsinthia generalpractitioneruseofgenericallysubstitutableinhalerdevicesandtheimpactoftrainingondevicemasteryandmaintenanceofcorrectinhalertechnique