PURPOSE: To develop a technique that allows portable chest radiography to be performed through the glass door of a patient’s room in the emergency department. MATERIALS AND METHODS: A retrospective review of 100 radiographs (50 [mean age 59.4 ± 17.3, range 22-87; 30 women] performed with the modifie...

Descripción completa

Detalles Bibliográficos
Autores principales: Gange, Christopher P., Pahade, Jay K., Cortopassi, Isabel, Bader, Anna S., Bokhari, Jamal, Hoerner, Matthew, Thomas, Kelly M., Rubinowitz, Ami N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Radiological Society of North America 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7673079/
https://www.ncbi.nlm.nih.gov/pubmed/33778645
http://dx.doi.org/10.1148/ryct.2020200420
_version_ 1783611262416977920
author Gange, Christopher P.
Pahade, Jay K.
Cortopassi, Isabel
Bader, Anna S.
Bokhari, Jamal
Hoerner, Matthew
Thomas, Kelly M.
Rubinowitz, Ami N.
author_facet Gange, Christopher P.
Pahade, Jay K.
Cortopassi, Isabel
Bader, Anna S.
Bokhari, Jamal
Hoerner, Matthew
Thomas, Kelly M.
Rubinowitz, Ami N.
author_sort Gange, Christopher P.
collection PubMed
description PURPOSE: To develop a technique that allows portable chest radiography to be performed through the glass door of a patient’s room in the emergency department. MATERIALS AND METHODS: A retrospective review of 100 radiographs (50 [mean age 59.4 ± 17.3, range 22-87; 30 women] performed with the modified technique in April 2020, randomized with 50 [mean age 59 ± 21.6, range 19-100; 31 men] using the standard technique was completed by three thoracic radiologists to assess image quality. Radiation exposure estimates to patient and staff were calculated. A survey was created and sent to 32 x-ray technologists to assess their perceptions of the modified technique. Unpaired Ttests were used for numerical data. A P value < .05 was considered statistically significant. RESULTS: The entrance dose for a 50th percentile patient was the same between techniques, measuring 169 µGy. The measured technologist exposure from the modified technique assuming a 50th percentile patient and standing 6 feet to the side of the glass was 0.055 µGy, which was lower than standard technique technologist exposure of 0.088 µGy. Of the 100 portable chest radiographs evaluated by three reviewers, two reviewers rated all images as having diagnostic quality, while the other reviewer believed two of the standard images and one of the modified technique images were non-diagnostic. A total of 81% (26 of 32) of eligible technologists completed the survey. Results showed acceptance of the modified technique with the majority feeling safer and confirming conservation of PPE. Most technologists did not feel the modified technique was more difficult to perform. CONCLUSIONS: The studies acquired with the new technique remained diagnostic, patient radiation doses remained similar, and technologist dose exposure were decreased with modified positioning. Perceptions of the new modified technique by frontline staff were overwhelmingly positive.
format Online
Article
Text
id pubmed-7673079
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Radiological Society of North America
record_format MEDLINE/PubMed
spelling pubmed-76730792020-11-18 Social Distancing with Portable Chest Radiographs During the COVID-19 Pandemic: Assessment of Radiograph Technique and Image Quality Obtained at 6 Feet and Through Glass Gange, Christopher P. Pahade, Jay K. Cortopassi, Isabel Bader, Anna S. Bokhari, Jamal Hoerner, Matthew Thomas, Kelly M. Rubinowitz, Ami N. Radiol Cardiothorac Imaging Original Research PURPOSE: To develop a technique that allows portable chest radiography to be performed through the glass door of a patient’s room in the emergency department. MATERIALS AND METHODS: A retrospective review of 100 radiographs (50 [mean age 59.4 ± 17.3, range 22-87; 30 women] performed with the modified technique in April 2020, randomized with 50 [mean age 59 ± 21.6, range 19-100; 31 men] using the standard technique was completed by three thoracic radiologists to assess image quality. Radiation exposure estimates to patient and staff were calculated. A survey was created and sent to 32 x-ray technologists to assess their perceptions of the modified technique. Unpaired Ttests were used for numerical data. A P value < .05 was considered statistically significant. RESULTS: The entrance dose for a 50th percentile patient was the same between techniques, measuring 169 µGy. The measured technologist exposure from the modified technique assuming a 50th percentile patient and standing 6 feet to the side of the glass was 0.055 µGy, which was lower than standard technique technologist exposure of 0.088 µGy. Of the 100 portable chest radiographs evaluated by three reviewers, two reviewers rated all images as having diagnostic quality, while the other reviewer believed two of the standard images and one of the modified technique images were non-diagnostic. A total of 81% (26 of 32) of eligible technologists completed the survey. Results showed acceptance of the modified technique with the majority feeling safer and confirming conservation of PPE. Most technologists did not feel the modified technique was more difficult to perform. CONCLUSIONS: The studies acquired with the new technique remained diagnostic, patient radiation doses remained similar, and technologist dose exposure were decreased with modified positioning. Perceptions of the new modified technique by frontline staff were overwhelmingly positive. Radiological Society of North America 2020-11-12 /pmc/articles/PMC7673079/ /pubmed/33778645 http://dx.doi.org/10.1148/ryct.2020200420 Text en 2020 by the Radiological Society of North America, Inc. This article is made available via the PMC Open Access Subset for unrestricted re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the COVID-19 pandemic or until permissions are revoked in writing. Upon expiration of these permissions, PMC is granted a perpetual license to make this article available via PMC and Europe PMC, consistent with existing copyright protections.
spellingShingle Original Research
Gange, Christopher P.
Pahade, Jay K.
Cortopassi, Isabel
Bader, Anna S.
Bokhari, Jamal
Hoerner, Matthew
Thomas, Kelly M.
Rubinowitz, Ami N.
Social Distancing with Portable Chest Radiographs During the COVID-19 Pandemic: Assessment of Radiograph Technique and Image Quality Obtained at 6 Feet and Through Glass
title Social Distancing with Portable Chest Radiographs During the COVID-19 Pandemic: Assessment of Radiograph Technique and Image Quality Obtained at 6 Feet and Through Glass
title_full Social Distancing with Portable Chest Radiographs During the COVID-19 Pandemic: Assessment of Radiograph Technique and Image Quality Obtained at 6 Feet and Through Glass
title_fullStr Social Distancing with Portable Chest Radiographs During the COVID-19 Pandemic: Assessment of Radiograph Technique and Image Quality Obtained at 6 Feet and Through Glass
title_full_unstemmed Social Distancing with Portable Chest Radiographs During the COVID-19 Pandemic: Assessment of Radiograph Technique and Image Quality Obtained at 6 Feet and Through Glass
title_short Social Distancing with Portable Chest Radiographs During the COVID-19 Pandemic: Assessment of Radiograph Technique and Image Quality Obtained at 6 Feet and Through Glass
title_sort social distancing with portable chest radiographs during the covid-19 pandemic: assessment of radiograph technique and image quality obtained at 6 feet and through glass
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7673079/
https://www.ncbi.nlm.nih.gov/pubmed/33778645
http://dx.doi.org/10.1148/ryct.2020200420
work_keys_str_mv AT gangechristopherp socialdistancingwithportablechestradiographsduringthecovid19pandemicassessmentofradiographtechniqueandimagequalityobtainedat6feetandthroughglass
AT pahadejayk socialdistancingwithportablechestradiographsduringthecovid19pandemicassessmentofradiographtechniqueandimagequalityobtainedat6feetandthroughglass
AT cortopassiisabel socialdistancingwithportablechestradiographsduringthecovid19pandemicassessmentofradiographtechniqueandimagequalityobtainedat6feetandthroughglass
AT baderannas socialdistancingwithportablechestradiographsduringthecovid19pandemicassessmentofradiographtechniqueandimagequalityobtainedat6feetandthroughglass
AT bokharijamal socialdistancingwithportablechestradiographsduringthecovid19pandemicassessmentofradiographtechniqueandimagequalityobtainedat6feetandthroughglass
AT hoernermatthew socialdistancingwithportablechestradiographsduringthecovid19pandemicassessmentofradiographtechniqueandimagequalityobtainedat6feetandthroughglass
AT thomaskellym socialdistancingwithportablechestradiographsduringthecovid19pandemicassessmentofradiographtechniqueandimagequalityobtainedat6feetandthroughglass
AT rubinowitzamin socialdistancingwithportablechestradiographsduringthecovid19pandemicassessmentofradiographtechniqueandimagequalityobtainedat6feetandthroughglass