Cargando…

Real-Time Parallel Artificial Membrane Permeability Assay Based on Supramolecular Fluorescent Artificial Receptors

Parallel artificial membrane permeability assay (PAMPA) is a screening tool for the evaluation of drug permeability across various biological membrane systems in a microplate format. In PAMPA, a drug candidate is allowed to pass through the lipid layer of a particular well during an incubation perio...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Suhang, Zhiti, Anxhela, Barba-Bon, Andrea, Hennig, Andreas, Nau, Werner M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7673371/
https://www.ncbi.nlm.nih.gov/pubmed/33330387
http://dx.doi.org/10.3389/fchem.2020.597927
_version_ 1783611305079341056
author He, Suhang
Zhiti, Anxhela
Barba-Bon, Andrea
Hennig, Andreas
Nau, Werner M.
author_facet He, Suhang
Zhiti, Anxhela
Barba-Bon, Andrea
Hennig, Andreas
Nau, Werner M.
author_sort He, Suhang
collection PubMed
description Parallel artificial membrane permeability assay (PAMPA) is a screening tool for the evaluation of drug permeability across various biological membrane systems in a microplate format. In PAMPA, a drug candidate is allowed to pass through the lipid layer of a particular well during an incubation period of, typically, 10–16 h. In a second step, the samples of each well are transferred to a UV-Vis–compatible microplate and optically measured (applicable only to analytes with sufficient absorbance) or sampled by mass-spectrometric analysis. The required incubation period, sample transfer, and detection methods jointly limit the scalability of PAMPA to high-throughput screening format. We introduce a modification of the PAMPA method that allows direct fluorescence detection, without sample transfer, in real time (RT-PAMPA). The method employs the use of a fluorescent artificial receptor (FAR), composed of a macrocycle in combination with an encapsulated fluorescent dye, administered in the acceptor chamber of conventional PAMPA microplates. Because the detection principle relies on the molecular recognition of an analyte by the receptor and the associated fluorescence response, concentration changes of any analyte that binds to the receptor can be monitored (molecules with aromatic residues in the present example), regardless of the spectroscopic properties of the analyte itself. Moreover, because the fluorescence of the (upper) acceptor well can be read out directly by fluorescence in a microplate reader, the permeation of the drug through the planar lipid layer can be monitored in real time. Compared with the traditional assay, RT-PAMPA allows not only quantification of the permeability characteristics but also rapid differentiation between fast and slow diffusion events.
format Online
Article
Text
id pubmed-7673371
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-76733712020-12-15 Real-Time Parallel Artificial Membrane Permeability Assay Based on Supramolecular Fluorescent Artificial Receptors He, Suhang Zhiti, Anxhela Barba-Bon, Andrea Hennig, Andreas Nau, Werner M. Front Chem Chemistry Parallel artificial membrane permeability assay (PAMPA) is a screening tool for the evaluation of drug permeability across various biological membrane systems in a microplate format. In PAMPA, a drug candidate is allowed to pass through the lipid layer of a particular well during an incubation period of, typically, 10–16 h. In a second step, the samples of each well are transferred to a UV-Vis–compatible microplate and optically measured (applicable only to analytes with sufficient absorbance) or sampled by mass-spectrometric analysis. The required incubation period, sample transfer, and detection methods jointly limit the scalability of PAMPA to high-throughput screening format. We introduce a modification of the PAMPA method that allows direct fluorescence detection, without sample transfer, in real time (RT-PAMPA). The method employs the use of a fluorescent artificial receptor (FAR), composed of a macrocycle in combination with an encapsulated fluorescent dye, administered in the acceptor chamber of conventional PAMPA microplates. Because the detection principle relies on the molecular recognition of an analyte by the receptor and the associated fluorescence response, concentration changes of any analyte that binds to the receptor can be monitored (molecules with aromatic residues in the present example), regardless of the spectroscopic properties of the analyte itself. Moreover, because the fluorescence of the (upper) acceptor well can be read out directly by fluorescence in a microplate reader, the permeation of the drug through the planar lipid layer can be monitored in real time. Compared with the traditional assay, RT-PAMPA allows not only quantification of the permeability characteristics but also rapid differentiation between fast and slow diffusion events. Frontiers Media S.A. 2020-11-03 /pmc/articles/PMC7673371/ /pubmed/33330387 http://dx.doi.org/10.3389/fchem.2020.597927 Text en Copyright © 2020 He, Zhiti, Barba-Bon, Hennig and Nau. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Chemistry
He, Suhang
Zhiti, Anxhela
Barba-Bon, Andrea
Hennig, Andreas
Nau, Werner M.
Real-Time Parallel Artificial Membrane Permeability Assay Based on Supramolecular Fluorescent Artificial Receptors
title Real-Time Parallel Artificial Membrane Permeability Assay Based on Supramolecular Fluorescent Artificial Receptors
title_full Real-Time Parallel Artificial Membrane Permeability Assay Based on Supramolecular Fluorescent Artificial Receptors
title_fullStr Real-Time Parallel Artificial Membrane Permeability Assay Based on Supramolecular Fluorescent Artificial Receptors
title_full_unstemmed Real-Time Parallel Artificial Membrane Permeability Assay Based on Supramolecular Fluorescent Artificial Receptors
title_short Real-Time Parallel Artificial Membrane Permeability Assay Based on Supramolecular Fluorescent Artificial Receptors
title_sort real-time parallel artificial membrane permeability assay based on supramolecular fluorescent artificial receptors
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7673371/
https://www.ncbi.nlm.nih.gov/pubmed/33330387
http://dx.doi.org/10.3389/fchem.2020.597927
work_keys_str_mv AT hesuhang realtimeparallelartificialmembranepermeabilityassaybasedonsupramolecularfluorescentartificialreceptors
AT zhitianxhela realtimeparallelartificialmembranepermeabilityassaybasedonsupramolecularfluorescentartificialreceptors
AT barbabonandrea realtimeparallelartificialmembranepermeabilityassaybasedonsupramolecularfluorescentartificialreceptors
AT hennigandreas realtimeparallelartificialmembranepermeabilityassaybasedonsupramolecularfluorescentartificialreceptors
AT nauwernerm realtimeparallelartificialmembranepermeabilityassaybasedonsupramolecularfluorescentartificialreceptors