PURPOSE: To evaluate the intraocular pressure (IOP)-lowering effect of a multi-pressure dial (MPD) at targeted negative pressure settings. METHODS: Prospective, intrasubject controlled study of 65 healthy subjects randomized to receive no negative pressure for 60 minutes or negative pressure applica...

Descripción completa

Detalles Bibliográficos
Autores principales: Swan, Russell J., Ferguson, Tanner J., Shah, Manjool, Muir, Kelly W., Samuelson, Thomas W., Ahmed, Iqbal Ike K., Lindstrom, Richard L., Radcliffe, Nathan M., Berdahl, John P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7673999/
https://www.ncbi.nlm.nih.gov/pubmed/33240572
http://dx.doi.org/10.1167/tvst.9.12.19
_version_ 1783611432277901312
author Swan, Russell J.
Ferguson, Tanner J.
Shah, Manjool
Muir, Kelly W.
Samuelson, Thomas W.
Ahmed, Iqbal Ike K.
Lindstrom, Richard L.
Radcliffe, Nathan M.
Berdahl, John P.
author_facet Swan, Russell J.
Ferguson, Tanner J.
Shah, Manjool
Muir, Kelly W.
Samuelson, Thomas W.
Ahmed, Iqbal Ike K.
Lindstrom, Richard L.
Radcliffe, Nathan M.
Berdahl, John P.
author_sort Swan, Russell J.
collection PubMed
description PURPOSE: To evaluate the intraocular pressure (IOP)-lowering effect of a multi-pressure dial (MPD) at targeted negative pressure settings. METHODS: Prospective, intrasubject controlled study of 65 healthy subjects randomized to receive no negative pressure for 60 minutes or negative pressure application at designated levels of 25%, 50%, and 75% of baseline IOP for 20 minutes each. The main outcome measure was mean IOP with application of negative pressure. RESULTS: In the study eye group, from a baseline IOP of 15.8 ± 3.6 mm Hg, the mean IOP was 13.5 ± 3.4, 11.5 ± 3.1, and 10.2 ± 2.7 mm Hg with negative pressure settings of 25%, 50% and 75%, respectively. In the control eye group, from a baseline IOP of 15.5 ± 3.0 mm Hg, the mean IOP values at the same time points, without negative pressure, were 15.6 ± 3.0, 15.5 ± 2.5 and 15.3 ± 2.4 mm Hg. The difference between the mean IOPs of the two groups was significantly different at all negative pressure settings (P < 0.001) in comparison with baseline. There was one minor adverse event, a corneal abrasion, that was unrelated to device wear. CONCLUSIONS: Negative pressure application to the periocular space with a multi-pressure dial can produce titratable IOP reduction while the device is worn with active negative pressure. To our knowledge, this technology represents the first nonpharmacologic, nonlaser, nonsurgical method for IOP reduction. TRANSLATIONAL RELEVANCE: This represents the first study demonstrating the IOP-lowering ability of the multi-pressure dial, a device that uses a novel IOP-lowering strategy by delivering negative pressure to the periocular region.
format Online
Article
Text
id pubmed-7673999
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-76739992020-11-24 Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings Swan, Russell J. Ferguson, Tanner J. Shah, Manjool Muir, Kelly W. Samuelson, Thomas W. Ahmed, Iqbal Ike K. Lindstrom, Richard L. Radcliffe, Nathan M. Berdahl, John P. Transl Vis Sci Technol Article PURPOSE: To evaluate the intraocular pressure (IOP)-lowering effect of a multi-pressure dial (MPD) at targeted negative pressure settings. METHODS: Prospective, intrasubject controlled study of 65 healthy subjects randomized to receive no negative pressure for 60 minutes or negative pressure application at designated levels of 25%, 50%, and 75% of baseline IOP for 20 minutes each. The main outcome measure was mean IOP with application of negative pressure. RESULTS: In the study eye group, from a baseline IOP of 15.8 ± 3.6 mm Hg, the mean IOP was 13.5 ± 3.4, 11.5 ± 3.1, and 10.2 ± 2.7 mm Hg with negative pressure settings of 25%, 50% and 75%, respectively. In the control eye group, from a baseline IOP of 15.5 ± 3.0 mm Hg, the mean IOP values at the same time points, without negative pressure, were 15.6 ± 3.0, 15.5 ± 2.5 and 15.3 ± 2.4 mm Hg. The difference between the mean IOPs of the two groups was significantly different at all negative pressure settings (P < 0.001) in comparison with baseline. There was one minor adverse event, a corneal abrasion, that was unrelated to device wear. CONCLUSIONS: Negative pressure application to the periocular space with a multi-pressure dial can produce titratable IOP reduction while the device is worn with active negative pressure. To our knowledge, this technology represents the first nonpharmacologic, nonlaser, nonsurgical method for IOP reduction. TRANSLATIONAL RELEVANCE: This represents the first study demonstrating the IOP-lowering ability of the multi-pressure dial, a device that uses a novel IOP-lowering strategy by delivering negative pressure to the periocular region. The Association for Research in Vision and Ophthalmology 2020-11-13 /pmc/articles/PMC7673999/ /pubmed/33240572 http://dx.doi.org/10.1167/tvst.9.12.19 Text en Copyright 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Swan, Russell J.
Ferguson, Tanner J.
Shah, Manjool
Muir, Kelly W.
Samuelson, Thomas W.
Ahmed, Iqbal Ike K.
Lindstrom, Richard L.
Radcliffe, Nathan M.
Berdahl, John P.
Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings
title Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings
title_full Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings
title_fullStr Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings
title_full_unstemmed Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings
title_short Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings
title_sort evaluation of the iop-lowering effect of a multi-pressure dial at different negative pressure settings
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7673999/
https://www.ncbi.nlm.nih.gov/pubmed/33240572
http://dx.doi.org/10.1167/tvst.9.12.19
work_keys_str_mv AT swanrussellj evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings
AT fergusontannerj evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings
AT shahmanjool evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings
AT muirkellyw evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings
AT samuelsonthomasw evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings
AT ahmediqbalikek evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings
AT lindstromrichardl evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings
AT radcliffenathanm evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings
AT berdahljohnp evaluationoftheioploweringeffectofamultipressuredialatdifferentnegativepressuresettings