Cargando…
Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance
Experimental and derived data from three Helically Coiled Oscillating Heat Pipes (HCOHPs) charged with ethanol, methanol and deionized water working fluids respectively are presented. The data was obtained from prototypes of the HCOHPs fabricated out of copper and tested under laboratory conditions....
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7674279/ https://www.ncbi.nlm.nih.gov/pubmed/33241098 http://dx.doi.org/10.1016/j.dib.2020.106505 |
_version_ | 1783611470147223552 |
---|---|
author | Yeboah, Siegfried K. Darkwa, Jo |
author_facet | Yeboah, Siegfried K. Darkwa, Jo |
author_sort | Yeboah, Siegfried K. |
collection | PubMed |
description | Experimental and derived data from three Helically Coiled Oscillating Heat Pipes (HCOHPs) charged with ethanol, methanol and deionized water working fluids respectively are presented. The data was obtained from prototypes of the HCOHPs fabricated out of copper and tested under laboratory conditions. The primary data presented covers the HCOHP aspects, charging of the working fluid and temperature measurements from Omega K-type Thermocouples installed on the evaporators, condensers, adiabatic sections, and on the cylindrical copper vessel integrated with it. The derived data covers the HCOHPs performances and thermal contact resistance experienced during laboratory testing. The data on the aspects and charging of the working fluid provides useful information for the validation of design parameters of other heat pipes. The measured temperature data and the derived performance data can used to validate the performance of heat pipes in other studies and to depict performance profiles in standard text and reference books. The nature of the data presented as a whole would be useful for comparative analysis involving heat pipes and other passive heat transfer devices. |
format | Online Article Text |
id | pubmed-7674279 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-76742792020-11-24 Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance Yeboah, Siegfried K. Darkwa, Jo Data Brief Data Article Experimental and derived data from three Helically Coiled Oscillating Heat Pipes (HCOHPs) charged with ethanol, methanol and deionized water working fluids respectively are presented. The data was obtained from prototypes of the HCOHPs fabricated out of copper and tested under laboratory conditions. The primary data presented covers the HCOHP aspects, charging of the working fluid and temperature measurements from Omega K-type Thermocouples installed on the evaporators, condensers, adiabatic sections, and on the cylindrical copper vessel integrated with it. The derived data covers the HCOHPs performances and thermal contact resistance experienced during laboratory testing. The data on the aspects and charging of the working fluid provides useful information for the validation of design parameters of other heat pipes. The measured temperature data and the derived performance data can used to validate the performance of heat pipes in other studies and to depict performance profiles in standard text and reference books. The nature of the data presented as a whole would be useful for comparative analysis involving heat pipes and other passive heat transfer devices. Elsevier 2020-11-05 /pmc/articles/PMC7674279/ /pubmed/33241098 http://dx.doi.org/10.1016/j.dib.2020.106505 Text en © 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Data Article Yeboah, Siegfried K. Darkwa, Jo Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance |
title | Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance |
title_full | Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance |
title_fullStr | Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance |
title_full_unstemmed | Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance |
title_short | Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance |
title_sort | experimental data on helically coiled oscillating heat pipe (hcohp) design and thermal performance |
topic | Data Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7674279/ https://www.ncbi.nlm.nih.gov/pubmed/33241098 http://dx.doi.org/10.1016/j.dib.2020.106505 |
work_keys_str_mv | AT yeboahsiegfriedk experimentaldataonhelicallycoiledoscillatingheatpipehcohpdesignandthermalperformance AT darkwajo experimentaldataonhelicallycoiledoscillatingheatpipehcohpdesignandthermalperformance |