Cargando…
An overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the Medical Physics Working Group in the Japan Clinical Oncology Group–Radiation Therapy Study Group
The Japan Clinical Oncology Group–Radiation Therapy Study Group (JCOG-RTSG) has initiated several multicenter clinical trials for high-precision radiotherapy, which are presently ongoing. When conducting multi-center clinical trials, a large difference in physical quantities, such as the absolute do...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7674673/ https://www.ncbi.nlm.nih.gov/pubmed/32989445 http://dx.doi.org/10.1093/jrr/rraa089 |
_version_ | 1783611554549202944 |
---|---|
author | Nishio, Teiji Nakamura, Mitsuhiro Okamoto, Hiroyuki Kito, Satoshi Minemura, Toshiyuki Ozawa, Shuichi Kumazaki, Yu Ishikawa, Masayori Tohyama, Naoki Kurooka, Masahiko Nakashima, Takeo Shimizu, Hidetoshi Suzuki, Ryusuke Ishikura, Satoshi Nishimura, Yasumasa |
author_facet | Nishio, Teiji Nakamura, Mitsuhiro Okamoto, Hiroyuki Kito, Satoshi Minemura, Toshiyuki Ozawa, Shuichi Kumazaki, Yu Ishikawa, Masayori Tohyama, Naoki Kurooka, Masahiko Nakashima, Takeo Shimizu, Hidetoshi Suzuki, Ryusuke Ishikura, Satoshi Nishimura, Yasumasa |
author_sort | Nishio, Teiji |
collection | PubMed |
description | The Japan Clinical Oncology Group–Radiation Therapy Study Group (JCOG-RTSG) has initiated several multicenter clinical trials for high-precision radiotherapy, which are presently ongoing. When conducting multi-center clinical trials, a large difference in physical quantities, such as the absolute doses to the target and the organ at risk, as well as the irradiation localization accuracy, affects the treatment outcome. Therefore, the differences in the various physical quantities used in different institutions must be within an acceptable range for conducting multicenter clinical trials, and this must be verified with medical physics consideration. In 2011, Japan’s first Medical Physics Working Group (MPWG) in the JCOG-RTSG was established to perform this medical-physics-related verification for multicenter clinical trials. We have developed an auditing method to verify the accuracy of the absolute dose and the irradiation localization. Subsequently, we credentialed the participating institutions in the JCOG multicenter clinical trials that were using stereotactic body radiotherapy (SBRT) for lungs, intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for several disease sites, and proton beam therapy (PT) for the liver. From the verification results, accuracies of the absolute dose and the irradiation localization among the participating institutions of the multicenter clinical trial were assured, and the JCOG clinical trials could be initiated. |
format | Online Article Text |
id | pubmed-7674673 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-76746732020-11-24 An overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the Medical Physics Working Group in the Japan Clinical Oncology Group–Radiation Therapy Study Group Nishio, Teiji Nakamura, Mitsuhiro Okamoto, Hiroyuki Kito, Satoshi Minemura, Toshiyuki Ozawa, Shuichi Kumazaki, Yu Ishikawa, Masayori Tohyama, Naoki Kurooka, Masahiko Nakashima, Takeo Shimizu, Hidetoshi Suzuki, Ryusuke Ishikura, Satoshi Nishimura, Yasumasa J Radiat Res Miscellaneous The Japan Clinical Oncology Group–Radiation Therapy Study Group (JCOG-RTSG) has initiated several multicenter clinical trials for high-precision radiotherapy, which are presently ongoing. When conducting multi-center clinical trials, a large difference in physical quantities, such as the absolute doses to the target and the organ at risk, as well as the irradiation localization accuracy, affects the treatment outcome. Therefore, the differences in the various physical quantities used in different institutions must be within an acceptable range for conducting multicenter clinical trials, and this must be verified with medical physics consideration. In 2011, Japan’s first Medical Physics Working Group (MPWG) in the JCOG-RTSG was established to perform this medical-physics-related verification for multicenter clinical trials. We have developed an auditing method to verify the accuracy of the absolute dose and the irradiation localization. Subsequently, we credentialed the participating institutions in the JCOG multicenter clinical trials that were using stereotactic body radiotherapy (SBRT) for lungs, intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for several disease sites, and proton beam therapy (PT) for the liver. From the verification results, accuracies of the absolute dose and the irradiation localization among the participating institutions of the multicenter clinical trial were assured, and the JCOG clinical trials could be initiated. Oxford University Press 2020-09-29 /pmc/articles/PMC7674673/ /pubmed/32989445 http://dx.doi.org/10.1093/jrr/rraa089 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Miscellaneous Nishio, Teiji Nakamura, Mitsuhiro Okamoto, Hiroyuki Kito, Satoshi Minemura, Toshiyuki Ozawa, Shuichi Kumazaki, Yu Ishikawa, Masayori Tohyama, Naoki Kurooka, Masahiko Nakashima, Takeo Shimizu, Hidetoshi Suzuki, Ryusuke Ishikura, Satoshi Nishimura, Yasumasa An overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the Medical Physics Working Group in the Japan Clinical Oncology Group–Radiation Therapy Study Group |
title | An overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the Medical Physics Working Group in the Japan Clinical Oncology Group–Radiation Therapy Study Group |
title_full | An overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the Medical Physics Working Group in the Japan Clinical Oncology Group–Radiation Therapy Study Group |
title_fullStr | An overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the Medical Physics Working Group in the Japan Clinical Oncology Group–Radiation Therapy Study Group |
title_full_unstemmed | An overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the Medical Physics Working Group in the Japan Clinical Oncology Group–Radiation Therapy Study Group |
title_short | An overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the Medical Physics Working Group in the Japan Clinical Oncology Group–Radiation Therapy Study Group |
title_sort | overview of the medical-physics-related verification system for radiotherapy multicenter clinical trials by the medical physics working group in the japan clinical oncology group–radiation therapy study group |
topic | Miscellaneous |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7674673/ https://www.ncbi.nlm.nih.gov/pubmed/32989445 http://dx.doi.org/10.1093/jrr/rraa089 |
work_keys_str_mv | AT nishioteiji anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT nakamuramitsuhiro anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT okamotohiroyuki anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT kitosatoshi anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT minemuratoshiyuki anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT ozawashuichi anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT kumazakiyu anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT ishikawamasayori anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT tohyamanaoki anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT kurookamasahiko anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT nakashimatakeo anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT shimizuhidetoshi anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT suzukiryusuke anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT ishikurasatoshi anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT nishimurayasumasa anoverviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT nishioteiji overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT nakamuramitsuhiro overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT okamotohiroyuki overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT kitosatoshi overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT minemuratoshiyuki overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT ozawashuichi overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT kumazakiyu overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT ishikawamasayori overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT tohyamanaoki overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT kurookamasahiko overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT nakashimatakeo overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT shimizuhidetoshi overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT suzukiryusuke overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT ishikurasatoshi overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup AT nishimurayasumasa overviewofthemedicalphysicsrelatedverificationsystemforradiotherapymulticenterclinicaltrialsbythemedicalphysicsworkinggroupinthejapanclinicaloncologygroupradiationtherapystudygroup |