Cargando…

Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy

To design a new breast vacuum bag to reduce global and local setup errors in post-mastectomy radiation therapy (PMRT). A total of 24 PMRT patients were immobilized with an old vacuum bag and 26 PMRT patients were immobilized with a new vacuum bag. The registration results were analysed using four re...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Konglong, Xiong, Jie, Wang, Zhiguo, Wang, Weifeng, Li, Wan, Zhou, Jidan, Deng, Zhonghua, Li, Bin, Zhong, Renming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7674700/
https://www.ncbi.nlm.nih.gov/pubmed/32823282
http://dx.doi.org/10.1093/jrr/rraa066
_version_ 1783611560592146432
author Shen, Konglong
Xiong, Jie
Wang, Zhiguo
Wang, Weifeng
Li, Wan
Zhou, Jidan
Deng, Zhonghua
Li, Bin
Zhong, Renming
author_facet Shen, Konglong
Xiong, Jie
Wang, Zhiguo
Wang, Weifeng
Li, Wan
Zhou, Jidan
Deng, Zhonghua
Li, Bin
Zhong, Renming
author_sort Shen, Konglong
collection PubMed
description To design a new breast vacuum bag to reduce global and local setup errors in post-mastectomy radiation therapy (PMRT). A total of 24 PMRT patients were immobilized with an old vacuum bag and 26 PMRT patients were immobilized with a new vacuum bag. The registration results were analysed using four regions of interest (ROI): the global ROI [including the whole region of the planning target volume (PTV), G(ROI)], the supraclavicular area (S(ROI)), the ipsilateral chest wall region (C(ROI)) and the ipsilateral arm region (A(ROI)). The global and local setup errors of the two groups were compared. The global setup errors of the new vacuum group were significantly smaller than those in the old vacuum group with the exception of yaw axes (P < 0.05). The systematic error (Σ) and random error (σ) ranged from 1.21 to 2.13 mm. In the new vacuum group, the local setup errors in the medial-lateral (ML) direction and roll axes for C(ROI) (the Σ and σ ranged from 0.65 to 1.35 mm), and the local setup errors in ML and superior-inferior (SI) directions for S(ROI) were significantly smaller than those in the old vacuum group. The total required PTV margins for the chest wall in ML, SI, and anterior-posterior (AP) were 4.40, 3.12 and 3.77 mm respectively. The new vacuum bag can significantly reduce the global setup errors and local setup errors in PMRT. The respiratory motion of the chest wall was negligible, and the 5 mm PTV margin could cover the local setup errors in PMRT using the new vacuum bag with cone beam CT (CBCT) correction.
format Online
Article
Text
id pubmed-7674700
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-76747002020-11-24 Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy Shen, Konglong Xiong, Jie Wang, Zhiguo Wang, Weifeng Li, Wan Zhou, Jidan Deng, Zhonghua Li, Bin Zhong, Renming J Radiat Res Oncology/Medicine To design a new breast vacuum bag to reduce global and local setup errors in post-mastectomy radiation therapy (PMRT). A total of 24 PMRT patients were immobilized with an old vacuum bag and 26 PMRT patients were immobilized with a new vacuum bag. The registration results were analysed using four regions of interest (ROI): the global ROI [including the whole region of the planning target volume (PTV), G(ROI)], the supraclavicular area (S(ROI)), the ipsilateral chest wall region (C(ROI)) and the ipsilateral arm region (A(ROI)). The global and local setup errors of the two groups were compared. The global setup errors of the new vacuum group were significantly smaller than those in the old vacuum group with the exception of yaw axes (P < 0.05). The systematic error (Σ) and random error (σ) ranged from 1.21 to 2.13 mm. In the new vacuum group, the local setup errors in the medial-lateral (ML) direction and roll axes for C(ROI) (the Σ and σ ranged from 0.65 to 1.35 mm), and the local setup errors in ML and superior-inferior (SI) directions for S(ROI) were significantly smaller than those in the old vacuum group. The total required PTV margins for the chest wall in ML, SI, and anterior-posterior (AP) were 4.40, 3.12 and 3.77 mm respectively. The new vacuum bag can significantly reduce the global setup errors and local setup errors in PMRT. The respiratory motion of the chest wall was negligible, and the 5 mm PTV margin could cover the local setup errors in PMRT using the new vacuum bag with cone beam CT (CBCT) correction. Oxford University Press 2020-08-22 /pmc/articles/PMC7674700/ /pubmed/32823282 http://dx.doi.org/10.1093/jrr/rraa066 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Oncology/Medicine
Shen, Konglong
Xiong, Jie
Wang, Zhiguo
Wang, Weifeng
Li, Wan
Zhou, Jidan
Deng, Zhonghua
Li, Bin
Zhong, Renming
Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy
title Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy
title_full Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy
title_fullStr Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy
title_full_unstemmed Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy
title_short Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy
title_sort design of a new breast vacuum bag to reduce the global and local setup errors and to reduce ptv margin in post-mastectomy radiation therapy
topic Oncology/Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7674700/
https://www.ncbi.nlm.nih.gov/pubmed/32823282
http://dx.doi.org/10.1093/jrr/rraa066
work_keys_str_mv AT shenkonglong designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy
AT xiongjie designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy
AT wangzhiguo designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy
AT wangweifeng designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy
AT liwan designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy
AT zhoujidan designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy
AT dengzhonghua designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy
AT libin designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy
AT zhongrenming designofanewbreastvacuumbagtoreducetheglobalandlocalsetuperrorsandtoreduceptvmargininpostmastectomyradiationtherapy