Cargando…
Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake
BACKGROUND: Human milk (HM) lipid content is highly variable, and infants consume different volumes of milk. This makes precise sampling and calculation of the infant lipid intake problematic. OBJECTIVES: In order to describe inaccuracies of estimates of lipid content introduced by various sampling...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7675139/ https://www.ncbi.nlm.nih.gov/pubmed/32886106 http://dx.doi.org/10.1093/jn/nxaa246 |
_version_ | 1783611647997247488 |
---|---|
author | George, Alexandra D Gay, Melvin C L Murray, Kevin Muhlhausler, Beverly S Wlodek, Mary E Geddes, Donna T |
author_facet | George, Alexandra D Gay, Melvin C L Murray, Kevin Muhlhausler, Beverly S Wlodek, Mary E Geddes, Donna T |
author_sort | George, Alexandra D |
collection | PubMed |
description | BACKGROUND: Human milk (HM) lipid content is highly variable, and infants consume different volumes of milk. This makes precise sampling and calculation of the infant lipid intake problematic. OBJECTIVES: In order to describe inaccuracies of estimates of lipid content introduced by various sampling protocols, we compared the true infant lipid intake with estimated intakes using different milk sampling protocols. METHODS: Monthly milk samples (n = 1026) from months 1 to 6 of lactation were collected from 20 healthy, exclusively breastfeeding women. Infant lipid intake was measured by 24-hour test-weighing at month 3. Total lipid content was measured by creamatocrit. Concentrations and infant lipid intakes were calculated using 11 sampling protocols, using either the true milk intake or an average of 800 mL/d. These estimates were compared with the true infant lipid intake using repeated-measures ANOVA and linear mixed modeling with multiple comparisons. RESULTS: The mean maternal age was 32.0 years (SD ± 3.10), and infants were born term (40.1 ± 1.1 weeks) with a mean birth weight of 3.87 kg (SD ± 0.39). The mean true infant lipid intake was 28.6 g/d (SD ± 9.8). The mean estimated lipid intake using 1 morning pre-feed sample underestimated intake by >8.0 g/d. Estimates of infant lipid intake using other sampling protocols and an assumed intake volume of 800 mL/d also resulted in a wide range of differences (0.8–18.1 g/d) from the true intake. Use of 6 daily pre- and post-feed milk samples had a mean difference of only 0.1 g/d (95% CI, −2.9 to 2.7) from the true intake. CONCLUSIONS: A sampling protocol with 6 pre- and post-feed samples provides the most accurate estimate of lipid intake if it is not possible to perform 24-hour test weights. The potential inaccuracies of sampling protocols should be taken into consideration in the interpretation and translation of infant lipid intake results. |
format | Online Article Text |
id | pubmed-7675139 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-76751392020-11-24 Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake George, Alexandra D Gay, Melvin C L Murray, Kevin Muhlhausler, Beverly S Wlodek, Mary E Geddes, Donna T J Nutr Original Research Articles BACKGROUND: Human milk (HM) lipid content is highly variable, and infants consume different volumes of milk. This makes precise sampling and calculation of the infant lipid intake problematic. OBJECTIVES: In order to describe inaccuracies of estimates of lipid content introduced by various sampling protocols, we compared the true infant lipid intake with estimated intakes using different milk sampling protocols. METHODS: Monthly milk samples (n = 1026) from months 1 to 6 of lactation were collected from 20 healthy, exclusively breastfeeding women. Infant lipid intake was measured by 24-hour test-weighing at month 3. Total lipid content was measured by creamatocrit. Concentrations and infant lipid intakes were calculated using 11 sampling protocols, using either the true milk intake or an average of 800 mL/d. These estimates were compared with the true infant lipid intake using repeated-measures ANOVA and linear mixed modeling with multiple comparisons. RESULTS: The mean maternal age was 32.0 years (SD ± 3.10), and infants were born term (40.1 ± 1.1 weeks) with a mean birth weight of 3.87 kg (SD ± 0.39). The mean true infant lipid intake was 28.6 g/d (SD ± 9.8). The mean estimated lipid intake using 1 morning pre-feed sample underestimated intake by >8.0 g/d. Estimates of infant lipid intake using other sampling protocols and an assumed intake volume of 800 mL/d also resulted in a wide range of differences (0.8–18.1 g/d) from the true intake. Use of 6 daily pre- and post-feed milk samples had a mean difference of only 0.1 g/d (95% CI, −2.9 to 2.7) from the true intake. CONCLUSIONS: A sampling protocol with 6 pre- and post-feed samples provides the most accurate estimate of lipid intake if it is not possible to perform 24-hour test weights. The potential inaccuracies of sampling protocols should be taken into consideration in the interpretation and translation of infant lipid intake results. Oxford University Press 2020-09-04 /pmc/articles/PMC7675139/ /pubmed/32886106 http://dx.doi.org/10.1093/jn/nxaa246 Text en Copyright © The Author(s) on behalf of the American Society for Nutrition 2020. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Research Articles George, Alexandra D Gay, Melvin C L Murray, Kevin Muhlhausler, Beverly S Wlodek, Mary E Geddes, Donna T Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake |
title | Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake |
title_full | Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake |
title_fullStr | Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake |
title_full_unstemmed | Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake |
title_short | Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake |
title_sort | human milk sampling protocols affect estimation of infant lipid intake |
topic | Original Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7675139/ https://www.ncbi.nlm.nih.gov/pubmed/32886106 http://dx.doi.org/10.1093/jn/nxaa246 |
work_keys_str_mv | AT georgealexandrad humanmilksamplingprotocolsaffectestimationofinfantlipidintake AT gaymelvincl humanmilksamplingprotocolsaffectestimationofinfantlipidintake AT murraykevin humanmilksamplingprotocolsaffectestimationofinfantlipidintake AT muhlhauslerbeverlys humanmilksamplingprotocolsaffectestimationofinfantlipidintake AT wlodekmarye humanmilksamplingprotocolsaffectestimationofinfantlipidintake AT geddesdonnat humanmilksamplingprotocolsaffectestimationofinfantlipidintake |