Cargando…

Evaluation of Sterilization Performance for Vaporized-Hydrogen-Peroxide-Based Sterilizer with Diverse Controlled Parameters

[Image: see text] Hydrogen-peroxide-based low-temperature sterilization is a new sterilization technology for temperature-dependent medical devices. The effect of the process parameters of hydrogen-peroxide-based sterilizer on the sterilization performance of process challenge devices (PCDs) needs t...

Descripción completa

Detalles Bibliográficos
Autores principales: Noh, Mi Suk, Jung, Suk Hee, Kwon, Ohryun, Lee, Sang-Il, Yang, Sung-Jin, Hahm, Eunil, Jun, Bong-Hyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676334/
https://www.ncbi.nlm.nih.gov/pubmed/33225169
http://dx.doi.org/10.1021/acsomega.0c04208
_version_ 1783611752388231168
author Noh, Mi Suk
Jung, Suk Hee
Kwon, Ohryun
Lee, Sang-Il
Yang, Sung-Jin
Hahm, Eunil
Jun, Bong-Hyun
author_facet Noh, Mi Suk
Jung, Suk Hee
Kwon, Ohryun
Lee, Sang-Il
Yang, Sung-Jin
Hahm, Eunil
Jun, Bong-Hyun
author_sort Noh, Mi Suk
collection PubMed
description [Image: see text] Hydrogen-peroxide-based low-temperature sterilization is a new sterilization technology for temperature-dependent medical devices. The effect of the process parameters of hydrogen-peroxide-based sterilizer on the sterilization performance of process challenge devices (PCDs) needs to be investigated. Sterilant amount, operating temperature, vacuum pressure, diffusion time, and chamber loading of the sterilizer on the sterilization performance of PCDs were adjusted. Seven PCDs with various morphologies and material containing biological indicators (BI) (EZTest, Geobacillus stearothermophilus) were used to evaluate the sterilization performance. The sterilization success rates of PCDs were 86, 71, and 57% with controlled temperature and pressure, diffusion time, and sterilant volume injection, respectively. The PCD material and structure also obviously affected sterilization performance. The sterilization of PCD A is the least successful for all parameters. Meanwhile, the sterilization of PCD B was influenced by the diffusion time and the sterilant injection volume. PCD B and PCD C were successfully sterilized by controlling the temperature and pressure. The weights and volume of the sterilization loading chamber resulted in a different sterilization performance. Sterilization performances of PCD 1, PCD 2, and PCD 3 were <70, <90, and 100%, respectively. Sterilant volume, sterilant diffusion time, pressure, temperature, PCD types, and chamber loading were proven to be important process parameters of sterilizer that affect the sterilization performance of vaporized-hydrogen-peroxide-based sterilizers.
format Online
Article
Text
id pubmed-7676334
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-76763342020-11-20 Evaluation of Sterilization Performance for Vaporized-Hydrogen-Peroxide-Based Sterilizer with Diverse Controlled Parameters Noh, Mi Suk Jung, Suk Hee Kwon, Ohryun Lee, Sang-Il Yang, Sung-Jin Hahm, Eunil Jun, Bong-Hyun ACS Omega [Image: see text] Hydrogen-peroxide-based low-temperature sterilization is a new sterilization technology for temperature-dependent medical devices. The effect of the process parameters of hydrogen-peroxide-based sterilizer on the sterilization performance of process challenge devices (PCDs) needs to be investigated. Sterilant amount, operating temperature, vacuum pressure, diffusion time, and chamber loading of the sterilizer on the sterilization performance of PCDs were adjusted. Seven PCDs with various morphologies and material containing biological indicators (BI) (EZTest, Geobacillus stearothermophilus) were used to evaluate the sterilization performance. The sterilization success rates of PCDs were 86, 71, and 57% with controlled temperature and pressure, diffusion time, and sterilant volume injection, respectively. The PCD material and structure also obviously affected sterilization performance. The sterilization of PCD A is the least successful for all parameters. Meanwhile, the sterilization of PCD B was influenced by the diffusion time and the sterilant injection volume. PCD B and PCD C were successfully sterilized by controlling the temperature and pressure. The weights and volume of the sterilization loading chamber resulted in a different sterilization performance. Sterilization performances of PCD 1, PCD 2, and PCD 3 were <70, <90, and 100%, respectively. Sterilant volume, sterilant diffusion time, pressure, temperature, PCD types, and chamber loading were proven to be important process parameters of sterilizer that affect the sterilization performance of vaporized-hydrogen-peroxide-based sterilizers. American Chemical Society 2020-11-03 /pmc/articles/PMC7676334/ /pubmed/33225169 http://dx.doi.org/10.1021/acsomega.0c04208 Text en © 2020 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Noh, Mi Suk
Jung, Suk Hee
Kwon, Ohryun
Lee, Sang-Il
Yang, Sung-Jin
Hahm, Eunil
Jun, Bong-Hyun
Evaluation of Sterilization Performance for Vaporized-Hydrogen-Peroxide-Based Sterilizer with Diverse Controlled Parameters
title Evaluation of Sterilization Performance for Vaporized-Hydrogen-Peroxide-Based Sterilizer with Diverse Controlled Parameters
title_full Evaluation of Sterilization Performance for Vaporized-Hydrogen-Peroxide-Based Sterilizer with Diverse Controlled Parameters
title_fullStr Evaluation of Sterilization Performance for Vaporized-Hydrogen-Peroxide-Based Sterilizer with Diverse Controlled Parameters
title_full_unstemmed Evaluation of Sterilization Performance for Vaporized-Hydrogen-Peroxide-Based Sterilizer with Diverse Controlled Parameters
title_short Evaluation of Sterilization Performance for Vaporized-Hydrogen-Peroxide-Based Sterilizer with Diverse Controlled Parameters
title_sort evaluation of sterilization performance for vaporized-hydrogen-peroxide-based sterilizer with diverse controlled parameters
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676334/
https://www.ncbi.nlm.nih.gov/pubmed/33225169
http://dx.doi.org/10.1021/acsomega.0c04208
work_keys_str_mv AT nohmisuk evaluationofsterilizationperformanceforvaporizedhydrogenperoxidebasedsterilizerwithdiversecontrolledparameters
AT jungsukhee evaluationofsterilizationperformanceforvaporizedhydrogenperoxidebasedsterilizerwithdiversecontrolledparameters
AT kwonohryun evaluationofsterilizationperformanceforvaporizedhydrogenperoxidebasedsterilizerwithdiversecontrolledparameters
AT leesangil evaluationofsterilizationperformanceforvaporizedhydrogenperoxidebasedsterilizerwithdiversecontrolledparameters
AT yangsungjin evaluationofsterilizationperformanceforvaporizedhydrogenperoxidebasedsterilizerwithdiversecontrolledparameters
AT hahmeunil evaluationofsterilizationperformanceforvaporizedhydrogenperoxidebasedsterilizerwithdiversecontrolledparameters
AT junbonghyun evaluationofsterilizationperformanceforvaporizedhydrogenperoxidebasedsterilizerwithdiversecontrolledparameters