Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor

[Image: see text] Neurosurgical procedures often cause damage to the brain tissue at the periphery from surgical manipulations. Especially during retraction, a large amount of pressure could be applied on the brain surface, which can damage it, leading to brain herniation, which can be fatal for pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Karmakar, Rajat Subhra, Wang, Jer-Chyi, Huang, Yu-Ting, Lin, Kun-Ju, Wei, Kuo-Chen, Hsu, Yung-Hsin, Huang, Ying-Cheng, Lu, Yu-Jen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676343/
https://www.ncbi.nlm.nih.gov/pubmed/33225165
http://dx.doi.org/10.1021/acsomega.0c04142
_version_ 1783611754453925888
author Karmakar, Rajat Subhra
Wang, Jer-Chyi
Huang, Yu-Ting
Lin, Kun-Ju
Wei, Kuo-Chen
Hsu, Yung-Hsin
Huang, Ying-Cheng
Lu, Yu-Jen
author_facet Karmakar, Rajat Subhra
Wang, Jer-Chyi
Huang, Yu-Ting
Lin, Kun-Ju
Wei, Kuo-Chen
Hsu, Yung-Hsin
Huang, Ying-Cheng
Lu, Yu-Jen
author_sort Karmakar, Rajat Subhra
collection PubMed
description [Image: see text] Neurosurgical procedures often cause damage to the brain tissue at the periphery from surgical manipulations. Especially during retraction, a large amount of pressure could be applied on the brain surface, which can damage it, leading to brain herniation, which can be fatal for patients. To resolve this issue, we have developed a pressure sensor that can be used to monitor the applied pressure during surgery for intraoperative care. This device was tested on a rodent model to create a superficial surgically induced damage profile for three different applied pressures (30, 50, and 70 mmHg) and compared to a standard intracranial pressure monitoring system. Magnetic resonance imaging has been performed after surgical procedures to detect the herniation caused by applied pressure. To evaluate the damage to brain cells and tissue rupture, histological analysis was performed using hematoxylin and eosin staining. A scoring system was developed to understand the severity of the surgically induced brain injury, which will help neurosurgeons to limit the pressure to an optimum point without causing damage.
format Online
Article
Text
id pubmed-7676343
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-76763432020-11-20 Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor Karmakar, Rajat Subhra Wang, Jer-Chyi Huang, Yu-Ting Lin, Kun-Ju Wei, Kuo-Chen Hsu, Yung-Hsin Huang, Ying-Cheng Lu, Yu-Jen ACS Omega [Image: see text] Neurosurgical procedures often cause damage to the brain tissue at the periphery from surgical manipulations. Especially during retraction, a large amount of pressure could be applied on the brain surface, which can damage it, leading to brain herniation, which can be fatal for patients. To resolve this issue, we have developed a pressure sensor that can be used to monitor the applied pressure during surgery for intraoperative care. This device was tested on a rodent model to create a superficial surgically induced damage profile for three different applied pressures (30, 50, and 70 mmHg) and compared to a standard intracranial pressure monitoring system. Magnetic resonance imaging has been performed after surgical procedures to detect the herniation caused by applied pressure. To evaluate the damage to brain cells and tissue rupture, histological analysis was performed using hematoxylin and eosin staining. A scoring system was developed to understand the severity of the surgically induced brain injury, which will help neurosurgeons to limit the pressure to an optimum point without causing damage. American Chemical Society 2020-11-02 /pmc/articles/PMC7676343/ /pubmed/33225165 http://dx.doi.org/10.1021/acsomega.0c04142 Text en © 2020 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Karmakar, Rajat Subhra
Wang, Jer-Chyi
Huang, Yu-Ting
Lin, Kun-Ju
Wei, Kuo-Chen
Hsu, Yung-Hsin
Huang, Ying-Cheng
Lu, Yu-Jen
Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor
title Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor
title_full Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor
title_fullStr Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor
title_full_unstemmed Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor
title_short Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor
title_sort real-time intraoperative pressure monitoring to avoid surgically induced localized brain injury using a miniaturized piezoresistive pressure sensor
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676343/
https://www.ncbi.nlm.nih.gov/pubmed/33225165
http://dx.doi.org/10.1021/acsomega.0c04142
work_keys_str_mv AT karmakarrajatsubhra realtimeintraoperativepressuremonitoringtoavoidsurgicallyinducedlocalizedbraininjuryusingaminiaturizedpiezoresistivepressuresensor
AT wangjerchyi realtimeintraoperativepressuremonitoringtoavoidsurgicallyinducedlocalizedbraininjuryusingaminiaturizedpiezoresistivepressuresensor
AT huangyuting realtimeintraoperativepressuremonitoringtoavoidsurgicallyinducedlocalizedbraininjuryusingaminiaturizedpiezoresistivepressuresensor
AT linkunju realtimeintraoperativepressuremonitoringtoavoidsurgicallyinducedlocalizedbraininjuryusingaminiaturizedpiezoresistivepressuresensor
AT weikuochen realtimeintraoperativepressuremonitoringtoavoidsurgicallyinducedlocalizedbraininjuryusingaminiaturizedpiezoresistivepressuresensor
AT hsuyunghsin realtimeintraoperativepressuremonitoringtoavoidsurgicallyinducedlocalizedbraininjuryusingaminiaturizedpiezoresistivepressuresensor
AT huangyingcheng realtimeintraoperativepressuremonitoringtoavoidsurgicallyinducedlocalizedbraininjuryusingaminiaturizedpiezoresistivepressuresensor
AT luyujen realtimeintraoperativepressuremonitoringtoavoidsurgicallyinducedlocalizedbraininjuryusingaminiaturizedpiezoresistivepressuresensor