Cargando…
Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer
To compare the effects of different photon energies on radiation planning by intensity-modulated radiotherapy (IMRT), volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO) for proximal gastric cancer (PGC). Network analysis with microarray procession and gene ontology were used to i...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676572/ https://www.ncbi.nlm.nih.gov/pubmed/33217871 http://dx.doi.org/10.1097/MD.0000000000023328 |
_version_ | 1783611799194566656 |
---|---|
author | Huang, Sheng-Fang Lin, Jang-Chun Shiau, An-Cheng Chen, Yun-Chih Li, Ming-Hsien Tsai, Jo-Ting Liu, Wei-Hsiu |
author_facet | Huang, Sheng-Fang Lin, Jang-Chun Shiau, An-Cheng Chen, Yun-Chih Li, Ming-Hsien Tsai, Jo-Ting Liu, Wei-Hsiu |
author_sort | Huang, Sheng-Fang |
collection | PubMed |
description | To compare the effects of different photon energies on radiation planning by intensity-modulated radiotherapy (IMRT), volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO) for proximal gastric cancer (PGC). Network analysis with microarray procession and gene ontology were used to identify the effect of radiotherapy (RT) on PGC. Then, we retrospectively analyzed 8 PGC patients after receiving irradiation with a prescribed dose of 50.4 Gy. The Pinnacle treatment planning system (TPS, V9.8) was used to generate IMRT and VMAT plans by using 6 or 10 MV. TOMO plans were calculated on the Tomotherapy Planning Station Hi-Art Version 4.2.3 workstation (Tomotherapy Incorporated, Madison, WI, USA). PGC is associated with high DNA repair ability. TOMO plan results in higher tumor coverage and a better conformity index than IMRT and VMAT. 10-MV VMAT yields better dosimetric quality of the gradient index than 6-MV VMAT (P = .012). TOMO was associated with a lower irradiation dose in the mean dose to the right kidney (P = .049), left kidney and heart than 6-MV IMRT and 6-MV VMAT. 6-MV IMRT plan presented a higher dose of lung D(mean) (P = .017) than 10-MV IMRT. Additionally, VMAT, using a planning energy of 6 MV, was associated with a significantly higher left kidney D(mean) (P = .018) and V(10) (P = .036) than a planning energy of 10 MV. TOMO is a better RT plan not only for tumor coverage but also for sparing organs at risk. IMRT and VMAT plans with 10 MV beams are more suitable than 6 MV beams for PGC treatment. |
format | Online Article Text |
id | pubmed-7676572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-76765722020-11-24 Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer Huang, Sheng-Fang Lin, Jang-Chun Shiau, An-Cheng Chen, Yun-Chih Li, Ming-Hsien Tsai, Jo-Ting Liu, Wei-Hsiu Medicine (Baltimore) 5700 To compare the effects of different photon energies on radiation planning by intensity-modulated radiotherapy (IMRT), volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO) for proximal gastric cancer (PGC). Network analysis with microarray procession and gene ontology were used to identify the effect of radiotherapy (RT) on PGC. Then, we retrospectively analyzed 8 PGC patients after receiving irradiation with a prescribed dose of 50.4 Gy. The Pinnacle treatment planning system (TPS, V9.8) was used to generate IMRT and VMAT plans by using 6 or 10 MV. TOMO plans were calculated on the Tomotherapy Planning Station Hi-Art Version 4.2.3 workstation (Tomotherapy Incorporated, Madison, WI, USA). PGC is associated with high DNA repair ability. TOMO plan results in higher tumor coverage and a better conformity index than IMRT and VMAT. 10-MV VMAT yields better dosimetric quality of the gradient index than 6-MV VMAT (P = .012). TOMO was associated with a lower irradiation dose in the mean dose to the right kidney (P = .049), left kidney and heart than 6-MV IMRT and 6-MV VMAT. 6-MV IMRT plan presented a higher dose of lung D(mean) (P = .017) than 10-MV IMRT. Additionally, VMAT, using a planning energy of 6 MV, was associated with a significantly higher left kidney D(mean) (P = .018) and V(10) (P = .036) than a planning energy of 10 MV. TOMO is a better RT plan not only for tumor coverage but also for sparing organs at risk. IMRT and VMAT plans with 10 MV beams are more suitable than 6 MV beams for PGC treatment. Lippincott Williams & Wilkins 2020-11-20 /pmc/articles/PMC7676572/ /pubmed/33217871 http://dx.doi.org/10.1097/MD.0000000000023328 Text en Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 |
spellingShingle | 5700 Huang, Sheng-Fang Lin, Jang-Chun Shiau, An-Cheng Chen, Yun-Chih Li, Ming-Hsien Tsai, Jo-Ting Liu, Wei-Hsiu Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer |
title | Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer |
title_full | Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer |
title_fullStr | Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer |
title_full_unstemmed | Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer |
title_short | Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer |
title_sort | optimal tumor coverage with different beam energies by imrt, vmat and tomo: effects on patients with proximal gastric cancer |
topic | 5700 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676572/ https://www.ncbi.nlm.nih.gov/pubmed/33217871 http://dx.doi.org/10.1097/MD.0000000000023328 |
work_keys_str_mv | AT huangshengfang optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer AT linjangchun optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer AT shiauancheng optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer AT chenyunchih optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer AT liminghsien optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer AT tsaijoting optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer AT liuweihsiu optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer |