Cargando…

Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer

To compare the effects of different photon energies on radiation planning by intensity-modulated radiotherapy (IMRT), volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO) for proximal gastric cancer (PGC). Network analysis with microarray procession and gene ontology were used to i...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Sheng-Fang, Lin, Jang-Chun, Shiau, An-Cheng, Chen, Yun-Chih, Li, Ming-Hsien, Tsai, Jo-Ting, Liu, Wei-Hsiu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676572/
https://www.ncbi.nlm.nih.gov/pubmed/33217871
http://dx.doi.org/10.1097/MD.0000000000023328
_version_ 1783611799194566656
author Huang, Sheng-Fang
Lin, Jang-Chun
Shiau, An-Cheng
Chen, Yun-Chih
Li, Ming-Hsien
Tsai, Jo-Ting
Liu, Wei-Hsiu
author_facet Huang, Sheng-Fang
Lin, Jang-Chun
Shiau, An-Cheng
Chen, Yun-Chih
Li, Ming-Hsien
Tsai, Jo-Ting
Liu, Wei-Hsiu
author_sort Huang, Sheng-Fang
collection PubMed
description To compare the effects of different photon energies on radiation planning by intensity-modulated radiotherapy (IMRT), volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO) for proximal gastric cancer (PGC). Network analysis with microarray procession and gene ontology were used to identify the effect of radiotherapy (RT) on PGC. Then, we retrospectively analyzed 8 PGC patients after receiving irradiation with a prescribed dose of 50.4 Gy. The Pinnacle treatment planning system (TPS, V9.8) was used to generate IMRT and VMAT plans by using 6 or 10 MV. TOMO plans were calculated on the Tomotherapy Planning Station Hi-Art Version 4.2.3 workstation (Tomotherapy Incorporated, Madison, WI, USA). PGC is associated with high DNA repair ability. TOMO plan results in higher tumor coverage and a better conformity index than IMRT and VMAT. 10-MV VMAT yields better dosimetric quality of the gradient index than 6-MV VMAT (P = .012). TOMO was associated with a lower irradiation dose in the mean dose to the right kidney (P = .049), left kidney and heart than 6-MV IMRT and 6-MV VMAT. 6-MV IMRT plan presented a higher dose of lung D(mean) (P = .017) than 10-MV IMRT. Additionally, VMAT, using a planning energy of 6 MV, was associated with a significantly higher left kidney D(mean) (P = .018) and V(10) (P = .036) than a planning energy of 10 MV. TOMO is a better RT plan not only for tumor coverage but also for sparing organs at risk. IMRT and VMAT plans with 10 MV beams are more suitable than 6 MV beams for PGC treatment.
format Online
Article
Text
id pubmed-7676572
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-76765722020-11-24 Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer Huang, Sheng-Fang Lin, Jang-Chun Shiau, An-Cheng Chen, Yun-Chih Li, Ming-Hsien Tsai, Jo-Ting Liu, Wei-Hsiu Medicine (Baltimore) 5700 To compare the effects of different photon energies on radiation planning by intensity-modulated radiotherapy (IMRT), volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO) for proximal gastric cancer (PGC). Network analysis with microarray procession and gene ontology were used to identify the effect of radiotherapy (RT) on PGC. Then, we retrospectively analyzed 8 PGC patients after receiving irradiation with a prescribed dose of 50.4 Gy. The Pinnacle treatment planning system (TPS, V9.8) was used to generate IMRT and VMAT plans by using 6 or 10 MV. TOMO plans were calculated on the Tomotherapy Planning Station Hi-Art Version 4.2.3 workstation (Tomotherapy Incorporated, Madison, WI, USA). PGC is associated with high DNA repair ability. TOMO plan results in higher tumor coverage and a better conformity index than IMRT and VMAT. 10-MV VMAT yields better dosimetric quality of the gradient index than 6-MV VMAT (P = .012). TOMO was associated with a lower irradiation dose in the mean dose to the right kidney (P = .049), left kidney and heart than 6-MV IMRT and 6-MV VMAT. 6-MV IMRT plan presented a higher dose of lung D(mean) (P = .017) than 10-MV IMRT. Additionally, VMAT, using a planning energy of 6 MV, was associated with a significantly higher left kidney D(mean) (P = .018) and V(10) (P = .036) than a planning energy of 10 MV. TOMO is a better RT plan not only for tumor coverage but also for sparing organs at risk. IMRT and VMAT plans with 10 MV beams are more suitable than 6 MV beams for PGC treatment. Lippincott Williams & Wilkins 2020-11-20 /pmc/articles/PMC7676572/ /pubmed/33217871 http://dx.doi.org/10.1097/MD.0000000000023328 Text en Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0
spellingShingle 5700
Huang, Sheng-Fang
Lin, Jang-Chun
Shiau, An-Cheng
Chen, Yun-Chih
Li, Ming-Hsien
Tsai, Jo-Ting
Liu, Wei-Hsiu
Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer
title Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer
title_full Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer
title_fullStr Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer
title_full_unstemmed Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer
title_short Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer
title_sort optimal tumor coverage with different beam energies by imrt, vmat and tomo: effects on patients with proximal gastric cancer
topic 5700
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676572/
https://www.ncbi.nlm.nih.gov/pubmed/33217871
http://dx.doi.org/10.1097/MD.0000000000023328
work_keys_str_mv AT huangshengfang optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer
AT linjangchun optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer
AT shiauancheng optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer
AT chenyunchih optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer
AT liminghsien optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer
AT tsaijoting optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer
AT liuweihsiu optimaltumorcoveragewithdifferentbeamenergiesbyimrtvmatandtomoeffectsonpatientswithproximalgastriccancer