Cargando…

Learning curve and performance in simulated difficult airway for the novel C-MAC(®) video-stylet and C-MAC(®) Macintosh video laryngoscope: A prospective randomized manikin trial

Difficult airways can be managed with a range of devices, with video laryngoscopes (VLs) being the most common. The C-MAC(®) Video-Stylet (VS; Karl-Storz Germany), a hybrid between a flexible and a rigid intubation endoscope, has been recently introduced. The aim of this study is to investigate the...

Descripción completa

Detalles Bibliográficos
Autores principales: Pius, James, Noppens, Ruediger R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676690/
https://www.ncbi.nlm.nih.gov/pubmed/33211728
http://dx.doi.org/10.1371/journal.pone.0242154
_version_ 1783611823589687296
author Pius, James
Noppens, Ruediger R.
author_facet Pius, James
Noppens, Ruediger R.
author_sort Pius, James
collection PubMed
description Difficult airways can be managed with a range of devices, with video laryngoscopes (VLs) being the most common. The C-MAC(®) Video-Stylet (VS; Karl-Storz Germany), a hybrid between a flexible and a rigid intubation endoscope, has been recently introduced. The aim of this study is to investigate the performance of the VS compared to a VL (C-MAC Macintosh blade, Karl-Storz Germany) with regards to the learning curve for each device and its ability to manage a simulated difficult airway manikin. This is a single-center, prospective, randomized, crossover study involving twenty-one anesthesia residents performing intubations on a Bill 1(™) (VBM, Germany) airway manikin model. After a standardized introduction, six randomized attempts with VL and VS were performed on the manikin. This was followed by intubation in a simulated difficult airway (cervical collar and inflated tongue) with both devices in a randomized fashion. The primary end-point of this study was the total time to intubation. All continuous variables were expressed as the median [interquartile range] and analyzed using the Mann-Whitney U test. A 2-way ANOVA with Bonferroni’s post hoc test was used to compare both devices at each trial. All reported p values are two sided. The median total time to intubation on a simulated difficult airway was faster with the VS compared to VL (17 [13.5–25] sec vs 23 [18.5–26.5] sec, respectively; 95% CI; P = 0.031). Additionally, on a normal airway manikin, the VS has a comparable learning curve to the VL. In this manikin-based study, the novel VS was comparable to the VL in terms of learning curve in a normal airway. In a simulated difficult airway, the total time to intubation, though likely not clinically relevant, was faster with the VS to the VL. However, given the above findings, this study justifies further human clinical trials with the VS to see if similar benefits–faster time to intubation and similar learning curve to VL–are replicated clinically.
format Online
Article
Text
id pubmed-7676690
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-76766902020-12-02 Learning curve and performance in simulated difficult airway for the novel C-MAC(®) video-stylet and C-MAC(®) Macintosh video laryngoscope: A prospective randomized manikin trial Pius, James Noppens, Ruediger R. PLoS One Research Article Difficult airways can be managed with a range of devices, with video laryngoscopes (VLs) being the most common. The C-MAC(®) Video-Stylet (VS; Karl-Storz Germany), a hybrid between a flexible and a rigid intubation endoscope, has been recently introduced. The aim of this study is to investigate the performance of the VS compared to a VL (C-MAC Macintosh blade, Karl-Storz Germany) with regards to the learning curve for each device and its ability to manage a simulated difficult airway manikin. This is a single-center, prospective, randomized, crossover study involving twenty-one anesthesia residents performing intubations on a Bill 1(™) (VBM, Germany) airway manikin model. After a standardized introduction, six randomized attempts with VL and VS were performed on the manikin. This was followed by intubation in a simulated difficult airway (cervical collar and inflated tongue) with both devices in a randomized fashion. The primary end-point of this study was the total time to intubation. All continuous variables were expressed as the median [interquartile range] and analyzed using the Mann-Whitney U test. A 2-way ANOVA with Bonferroni’s post hoc test was used to compare both devices at each trial. All reported p values are two sided. The median total time to intubation on a simulated difficult airway was faster with the VS compared to VL (17 [13.5–25] sec vs 23 [18.5–26.5] sec, respectively; 95% CI; P = 0.031). Additionally, on a normal airway manikin, the VS has a comparable learning curve to the VL. In this manikin-based study, the novel VS was comparable to the VL in terms of learning curve in a normal airway. In a simulated difficult airway, the total time to intubation, though likely not clinically relevant, was faster with the VS to the VL. However, given the above findings, this study justifies further human clinical trials with the VS to see if similar benefits–faster time to intubation and similar learning curve to VL–are replicated clinically. Public Library of Science 2020-11-19 /pmc/articles/PMC7676690/ /pubmed/33211728 http://dx.doi.org/10.1371/journal.pone.0242154 Text en © 2020 Pius, Noppens http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Pius, James
Noppens, Ruediger R.
Learning curve and performance in simulated difficult airway for the novel C-MAC(®) video-stylet and C-MAC(®) Macintosh video laryngoscope: A prospective randomized manikin trial
title Learning curve and performance in simulated difficult airway for the novel C-MAC(®) video-stylet and C-MAC(®) Macintosh video laryngoscope: A prospective randomized manikin trial
title_full Learning curve and performance in simulated difficult airway for the novel C-MAC(®) video-stylet and C-MAC(®) Macintosh video laryngoscope: A prospective randomized manikin trial
title_fullStr Learning curve and performance in simulated difficult airway for the novel C-MAC(®) video-stylet and C-MAC(®) Macintosh video laryngoscope: A prospective randomized manikin trial
title_full_unstemmed Learning curve and performance in simulated difficult airway for the novel C-MAC(®) video-stylet and C-MAC(®) Macintosh video laryngoscope: A prospective randomized manikin trial
title_short Learning curve and performance in simulated difficult airway for the novel C-MAC(®) video-stylet and C-MAC(®) Macintosh video laryngoscope: A prospective randomized manikin trial
title_sort learning curve and performance in simulated difficult airway for the novel c-mac(®) video-stylet and c-mac(®) macintosh video laryngoscope: a prospective randomized manikin trial
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7676690/
https://www.ncbi.nlm.nih.gov/pubmed/33211728
http://dx.doi.org/10.1371/journal.pone.0242154
work_keys_str_mv AT piusjames learningcurveandperformanceinsimulateddifficultairwayforthenovelcmacvideostyletandcmacmacintoshvideolaryngoscopeaprospectiverandomizedmanikintrial
AT noppensruedigerr learningcurveandperformanceinsimulateddifficultairwayforthenovelcmacvideostyletandcmacmacintoshvideolaryngoscopeaprospectiverandomizedmanikintrial